Group: Terasaki
Catalog excerpts
MINIATURE CIRCUIT BREAKERS RESIDUAL CURRENT CIRCUIT BREAKERS TD3 M06 6kA MCBs Functions: protection against overloads and short circuits, switching and isolation. Application: in commercial and industrial electrical distribution systems. TD3 M10 10kA MCBs Functions: protection against overloads and short circuits, switching and isolation. Application: in commercial and industrial electrical distribution systems. TD31P1M 1 pole + N in 1 module Functions: protection against overloads and short circuits, switching and isolation. Application: single phase circuits where neutral must be switched. Breaking capacity: Icn = 6kA to EN 60898. Certified by KEMA Voltage: Un: 230 -240V AC phase-to-neutral, 400-415V AC phase-to-phase Pollution degree: 3 Rigid conductor: 25mm2 maximum Flexible conductor: 16mm2 maximum Dual bottom terminal allows simultaneous connection of busbar and cable Breaking capacity: Icn = 10kA to EN60898, Certified by KEMA Icu = 15kA to EN 60947-2 Voltage: Un: 230 -240V AC phase-to-neutral, 400-415V AC phase-to-phase Rigid conductor: 35mm2 maximum Flexible conductor: 25mm2 maximum Dual bottom terminal allows simultaneous connection of busbar and cable _ TD3 XA MCBs < 125A Functions: protection against overloads and short circuits, switching and isolation. Application: to feed large loads or downstream distribution boards Breaking capacity: Icn = 6kA to EN 60898 Voltage: Un: 240V AC Pollution degree: 2 Rigid conductor: 16mm2 maximum Flexible conductor: 10mm2 maximum single pole TD3RCBO Residual current circuit breaker with overload protection Function: detection and interruption of earth leakage current, overloads and short-circuits. Application: commercial premises. Neutral conductor is switched on 2-module versions and unswitched on 1-module versions Breaking capacity Icn: 6kA (2P), 10kA (1P) to EN 61009-1 Voltage: Un: 240V AC Rigid conductor: 16mm2 maximum (1P), 25mm2 maximum (2P) Flexible conductor: 10mm2 maximum (1P), 16mm2 (2P) Standard: EN 60947-3 Class: AC 22 Voltage: Un, 240V AC phase-to-neutral, 415V AC phase-to-phase Rigid conductor: 16mm2 maximum (32A), 25mm2 maximum (63A), 50mm2 maximum (100A, 125A) Flexible conductor: 10mm2 maximum (32A), 16mm2 maximum (63A), 35mm2 maximum (100A, 125A) TD3 MS Function: switching and isolation of circuits Application: control systems, distribution systems 63, 100*, 125 *Available with red toggle Standard: EN 61008-1 Voltage: Un: 240V AC phase-to-neutral, 415V AC phase-to-phase Residual current breaking capacity: Im = 1500A Rigid conductor: 25mm2 maximum Flexible conductor: 16mm2 maximum Standard: UNE EN 20317 Breaking Capacity: 6kA Voltage: Un, 230 -240V AC phase-to-neutral, 400-415V AC phase-to-phase Rigid conductor: 25mm2 maximum Flexible conductor: 16mm2 maximum Dual bottom terminal allows simultaneous connection of busbar and cable TD3RCCB Function: detection and interruption of earth leakage current Application: protection from electric shock. Must be combined with an upstream device providing appropriate overload and short-circuit protection for the circuit. Breaking capacity: Icn = 10kA to EN 60898 Breaking capacity: Icu = 10kA to EN 60947-2 Voltage: Un, 240V AC phase-to-neutral, 415V AC phase-to-phase Rigid conductor: 50mm2 maximum Flexible conductor: 35mm2 maximum TD3 ICP MINIATURE CIRCUIT BREAKERS FOR UTILITY SUPPLIES Function: protection against overloads and short-circuits. Switching and isolation. Application: restriction of maximum current supplied to user by electricity utility company MODULAR SWITCHES single pole single pole
Open the catalog to page 1Accessories for TD3 M06, TD3 M10, TD3 XA, TD3RCCB A Auxiliary contact, 1NO, 1NC. 6A, 230V AC . Not suitable for TD3RCCB B Alarm contact, 1NO, 1NC. 6A, 230V AC . Not suitable for TD3RCCB C RCCB switch. Combined auxiliary contact (1NO, 1NC. 6A, 230V AC) + Alarm contact (1NO, 1NC. 6A, 230V AC) D Shunt trip. RCCB switch (C) must be fitted before fitting the shunt trip to the TD3RCCB E Undervoltage trip. RCCB switch (C) must be fitted before fitting the undervoltage trip to the TD3RCCB G Overvoltage trip. Rated voltage, Un, 230V AC. Opens the circuit breaker if supply voltage exceeds 280V AC....
Open the catalog to page 2All Terasaki (Europe) Circuit Breaker catalogs and technical brochures
-
POWER FACTOR CORRECTION
2 Pages
-
Contactors
16 Pages
-
Power Factor Correction
56 Pages
-
Moulded Case Circuit Breakers
203 Pages
-
TemPower 2 ACB Catalogue
80 Pages