DIN Modular Protection
2Pages

{{requestButtons}}

Catalog excerpts

DIN Modular Protection - 1

MINIATURE CIRCUIT BREAKERS RESIDUAL CURRENT CIRCUIT BREAKERS TD3 M06 6kA MCBs Functions: protection against overloads and short circuits, switching and isolation. Application: in commercial and industrial electrical distribution systems. TD3 M10 10kA MCBs Functions: protection against overloads and short circuits, switching and isolation. Application: in commercial and industrial electrical distribution systems. TD31P1M 1 pole + N in 1 module Functions: protection against overloads and short circuits, switching and isolation. Application: single phase circuits where neutral must be switched. Breaking capacity: Icn = 6kA to EN 60898. Certified by KEMA Voltage: Un: 230 -240V AC phase-to-neutral, 400-415V AC phase-to-phase Pollution degree: 3 Rigid conductor: 25mm2 maximum Flexible conductor: 16mm2 maximum Dual bottom terminal allows simultaneous connection of busbar and cable Breaking capacity: Icn = 10kA to EN60898, Certified by KEMA Icu = 15kA to EN 60947-2 Voltage: Un: 230 -240V AC phase-to-neutral, 400-415V AC phase-to-phase Rigid conductor: 35mm2 maximum Flexible conductor: 25mm2 maximum Dual bottom terminal allows simultaneous connection of busbar and cable _ TD3 XA MCBs < 125A Functions: protection against overloads and short circuits, switching and isolation. Application: to feed large loads or downstream distribution boards Breaking capacity: Icn = 6kA to EN 60898 Voltage: Un: 240V AC Pollution degree: 2 Rigid conductor: 16mm2 maximum Flexible conductor: 10mm2 maximum single pole TD3RCBO Residual current circuit breaker with overload protection Function: detection and interruption of earth leakage current, overloads and short-circuits. Application: commercial premises. Neutral conductor is switched on 2-module versions and unswitched on 1-module versions Breaking capacity Icn: 6kA (2P), 10kA (1P) to EN 61009-1 Voltage: Un: 240V AC Rigid conductor: 16mm2 maximum (1P), 25mm2 maximum (2P) Flexible conductor: 10mm2 maximum (1P), 16mm2 (2P) Standard: EN 60947-3 Class: AC 22 Voltage: Un, 240V AC phase-to-neutral, 415V AC phase-to-phase Rigid conductor: 16mm2 maximum (32A), 25mm2 maximum (63A), 50mm2 maximum (100A, 125A) Flexible conductor: 10mm2 maximum (32A), 16mm2 maximum (63A), 35mm2 maximum (100A, 125A) TD3 MS Function: switching and isolation of circuits Application: control systems, distribution systems 63, 100*, 125 *Available with red toggle Standard: EN 61008-1 Voltage: Un: 240V AC phase-to-neutral, 415V AC phase-to-phase Residual current breaking capacity: Im = 1500A Rigid conductor: 25mm2 maximum Flexible conductor: 16mm2 maximum Standard: UNE EN 20317 Breaking Capacity: 6kA Voltage: Un, 230 -240V AC phase-to-neutral, 400-415V AC phase-to-phase Rigid conductor: 25mm2 maximum Flexible conductor: 16mm2 maximum Dual bottom terminal allows simultaneous connection of busbar and cable TD3RCCB Function: detection and interruption of earth leakage current Application: protection from electric shock. Must be combined with an upstream device providing appropriate overload and short-circuit protection for the circuit. Breaking capacity: Icn = 10kA to EN 60898 Breaking capacity: Icu = 10kA to EN 60947-2 Voltage: Un, 240V AC phase-to-neutral, 415V AC phase-to-phase Rigid conductor: 50mm2 maximum Flexible conductor: 35mm2 maximum TD3 ICP MINIATURE CIRCUIT BREAKERS FOR UTILITY SUPPLIES Function: protection against overloads and short-circuits. Switching and isolation. Application: restriction of maximum current supplied to user by electricity utility company MODULAR SWITCHES single pole single pole

Open the catalog to page 1
DIN Modular Protection - 2

Accessories for TD3 M06, TD3 M10, TD3 XA, TD3RCCB A Auxiliary contact, 1NO, 1NC. 6A, 230V AC . Not suitable for TD3RCCB B Alarm contact, 1NO, 1NC. 6A, 230V AC . Not suitable for TD3RCCB C RCCB switch. Combined auxiliary contact (1NO, 1NC. 6A, 230V AC) + Alarm contact (1NO, 1NC. 6A, 230V AC) D Shunt trip. RCCB switch (C) must be fitted before fitting the shunt trip to the TD3RCCB E Undervoltage trip. RCCB switch (C) must be fitted before fitting the undervoltage trip to the TD3RCCB G Overvoltage trip. Rated voltage, Un, 230V AC. Opens the circuit breaker if supply voltage exceeds 280V AC....

Open the catalog to page 2

All Terasaki (Europe) Circuit Breaker catalogs and technical brochures

  1. Contactors

    16 Pages