Ratings and Specifications
Molded Case Circuit Breakers (MCCBs) are available in fixed and adjustable thermal and magnetic types. Key specifications include rated current, insulation voltage, impulse withstand voltage, and breaking capacity. Detailed ratings are provided for models like S160-SF and E250-SF, covering rated current, breaking capacity, and dimensions.
Mounting and Connection
The document describes connection types and mounting options for MCCBs, such as front-connected, rear-connected, and plug-in types. It includes details on compression terminals, extension bars, and cable clamps, with specific configurations for different breaker models.
Accessories
Internally mounted accessories include auxiliary switches, alarm switches, shunt trip devices, and undervoltage trip devices. Externally mounted accessories include motor operators, toggle holders, and external operating handles. Compatibility and installation options for each accessory type are specified.
Characteristics and Outline Dimensions
Dimensions and characteristics for various MCCB models are detailed, highlighting compact size and high breaking capacity. Features include IP20 and IP30 protection levels, unique accessory covers, and adjustable overload protection.
Features
Key features include varied terminations, compact size, high breaking capacity, and suitability for operation in pollution degree 3 environments. The document emphasizes ease of installation for internal accessories and secure design of accessory covers.
Specifications for Motor Operators
The document outlines specifications for motor operators used in circuit breakers, with rated operational voltages ranging from AC100-110V to DC200-220V. Peak steady-state and starting currents are specified, and motor operators are designed for short-time duty with a maximum of 10 continuous ON-OFF operations before a 15-minute cooling period. Operating time at rated voltage is 0.1 seconds for both ON and OFF/RESET operations.
Procedures
Motorized operation involves an input-signal self-hold circuit, while manual operation requires pulling and rotating the handle. An auto-reset feature automatically resets the breaker approximately 1.5 seconds after tripping.
Standards and Recommendations
The document recommends maintaining operation voltage between 85% and 110% of the rated voltage and using noise filters if the control power supply is shared with peripheral devices. Electrical interlock cables are advised when using motors with mechanical interlocks.
Features of Motor Operators
Motor operators offer high-speed, stable actuation with silent operation due to the direct drive system. They also have a "lock-in off" capability, allowing the breaker to be padlocked in the OFF state with up to three padlocks.
Accessories for Motor Operators
Accessories include interlock cables and external operating handles, which allow operation from outside a switchboard and include a panel lock mechanism.
Overview
The document provides detailed technical specifications and accessory options for various MCCB models, including dimensions, mounting options, and additional accessories to enhance functionality and safety.
Specifications
Dimensions and configurations for different breaker models are outlined, specifying component lengths and distances from the panel surface to the breaker mounting surface.
Accessories
Accessories such as external operating handles, interpole barriers, terminal covers, terminal blocks, and mechanical interlocks are detailed with their purpose, dimensions, and compatibility.
Interpole Barriers
Used to enhance electrical insulation between poles and prevent short circuits, interpole barriers cannot be used with terminal covers.
Terminal Covers
Available for front-connected, rear-connected, and plug-in breakers, terminal covers prevent exposure of live parts and come in various sizes and colors.
Mechanical Interlock
The slide interlock mechanism prevents two breakers from being closed simultaneously, with dimensions and order codes provided.
Door Flanges
Recommended for covering switchboard panel cutouts, door flanges are detailed with dimensions and installation instructions.
Ratings and Specifications
Includes ratings for current, voltage, and breaking capacity, along with time/current characteristic curves and ambient compensating curves for different breaker models.
Installation and Mounting
Instructions for mounting and connecting breakers are provided, including details on terminal screws, bolt studs, and plug-in options, along with drilling plans and panel cutout dimensions.
Conclusion
This technical document serves as a comprehensive guide for selecting and installing molded case circuit breakers and their accessories, ensuring proper configuration and safety in electrical systems.
See more

Catalog excerpts

TemBreak2-3

TABLE OF CONTENTS 1. Ratings and Specifications …………………………………………………………………………………………………1-1 Molded Case Circuit Breakers zFixed thermal and fixed magnetic MCCBs ………………………1-2 xAdjustable thermal and adjustable magnetic MCCBs …………1-3 1 2. Mounting and Connection ……………………………………………………………………………………………………2-1 zType of connections and mountings ……………………………2-2 cTerminal screw sizes and standard torques ……………………2-6 List of connecting type ……………………………………………2-2 vInsulation distance from the line side ……………………………2-7 nLists of breaker mounting screws …………………………………2-8 3. Accessories ……………………………………………………………………………………………………………………3-1...

 Open the catalog to page 3
TemBreak2-4

Saving space and saving money ! No.4 Operation in pollution degree 3 to IEC standard and high breaking capacity: 40kA and IP30 protection for the front cover with toggle (with terminal covers) Unique accessory cover opens with easily installed Practical internal with positive contact one touch • ayxiliary switch • alarm switch • shunt trip • undervoltage Huge adjustment Unlimited performance when reverse-connected protection: 63 to 100% Dial cover can be sealed. (Adjustable thermal Secure accessory cover retains nameplate VARIED TERMINATIONS cable clamp cable clamp for aluminum conductors front...

 Open the catalog to page 4
TemBreak2-5

Molded Case Circuit Breakers zFixed thermal and fixed magnetic MCCBs …………………………1-2 xAdjustable thermal and adjustable magnetic MCCBs ……………1-3 cSwitch-disconnectors …………………………………………………1-4

 Open the catalog to page 5
TemBreak2-6

Ratings and Specifications Molded Case Circuit Breakers zFixed thermal and fixed magnetic MCCBs 100 Externally mounted Internally mounted Weight (' marked standard type) kg ■Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug45B (PG4) DIN rail mount Clip-in chassis mount ■Accessories (optional) Symbol Auxiliary switch AX Alarm switch...

 Open the catalog to page 6
TemBreak2-7

Ratings and Specifications Molded Case Circuit Breakers xAdjustable thermal and fixed or adjustable magnetic MCCBs 160 Frame size (A) Type Number of poles ■Ratings Rated current, A Calibrated at 45°C Rated insulation voltage〔Ui〕 V Rated impulse withstand voltage 〔U imp〕 kV Utilization Category ■Rated breaking capacity, kA IEC60947-2 AC Icu/Ics(sym) ① DC ■Rated short time withstand current, kA ■External dimensions, mm d Externally mounted Internally mounted Weight (' marked standard type) kg ■Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread...

 Open the catalog to page 7
TemBreak2-8

Ratings and Specifications Molded Case Circuit Breakers cSwitch-disconnectors Frame size (A) Type Number of poles ■Ratings Rated current, A Rated insulation voltage〔Ui〕 V Rated operational voltage V Rated short circuit making capacity, kA peak Rated short time withstand current, kA Rated impulse withstand voltage 〔U imp〕 kV ■Performance Utilization category AC IEC 60947-3 DC Upstream breaker (OCPD) @9 ■External dimensions, mm d Externally mounted Internally mounted Weight (' marked standard type) kg ■Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With...

 Open the catalog to page 8
TemBreak2-9

zType of connections and mountings ……………………………………2-2 List of connecting type…………………………………………………………2-2 Connecting parts ………………………………………………………………2-3 xCompression terminals ……………………………………………………2-4 cTerminal screw sizes and standard torques ……………………………2-6 vInsulation distance from the line

 Open the catalog to page 9
TemBreak2-10

Connecting types (Abbreviation) For compression terminals / flat bars With extension bars With cable clamps Bolt studs Outer view Breaker E100-SF Connect compression terminals or flat bars directly to breaker terminals. Extension bars are attached to breaker terminals. Connect compression terminals or flat bars to the extension bars. Cable clamps are attached to breaker terminals. Connect wires directly to cable clamps. Flat bar studs will be factory installed in the horizontal position unless otherwise specified. ■ For E250, S250, the flat bar studs in the vertical position are available on...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.