Customer Care Commitments
Quality assurance is provided with a 12-month warranty against defects. The company holds ISO 9001 accreditation for manufacturing and distribution. Ordering is simplified with color-coded sections and order codes, and free technical support and application software are available. Contact details are provided for various regions worldwide.
Product Overview
TemBreak 2 is marketed as the Ultimate Safety Breaker, with safety features exceeding international standards, marked with Safety+. The product lines include Moulded Case Circuit Breakers (MCCBs) and Switch-Disconnectors.
TemBreak 2 Features
Features include rated current from 20A to 1600A, breaking capacity from 25kA to 200kA at 415V AC, modular sizes, field-installable accessories, advanced LCD display, safety lock for plug-in versions, and customizable tripping times.
Safety Plus
Direct Opening Action ensures safety in machinery applications, with compliance to international standards like IEC 60947-2 and JIS C 8201-2-1. Independent testing and marine approvals confirm reliability.
Environmental Impact
The product has a long life cycle with at least 30,000 mechanical operations and uses eco-friendly materials such as lead-free solder and cadmium-free contacts. It is supported by an ISO 14001 accredited Environmental Management System.
Ratings and Specifications
Detailed specifications for MCCBs and Switch-Disconnectors are provided, including various models with different current ratings and breaking capacities. Installation options include front connection, rear connection, and DIN rail mounting.
Operating Characteristics
Thermal magnetic protection is available for MCCBs from 125A to 800A frames, with adjustable thermal and magnetic characteristics. Applications include installations with harmonic distortion, DC circuits, and motor protection. Generator protection is also available.
Switch-Disconnector Electrical Characteristics
Specifications include frame and model details, electrical characteristics, installation options, and endurance for each model.
Safety Features
Safety features for plug-in MCCBs include a safety lock to prevent tripping during removal.
Operating Characteristics Overview
Specifications and characteristics of various frames of circuit breakers are detailed, focusing on thermal magnetic and electronic protection features, with time/current characteristic curves and adjustable settings.
Specifications
The document outlines specifications for the Ultimate Safety Breaker, focusing on electronic protection features with an LCD display. The breaker is available in three orientations, with specific control voltage requirements.
Measurement and Communication
The breaker supports measurement and event indication functions with Modbus communication capabilities, measuring load current, line voltage, harmonic current, electrical power, and energy.
Electronic Characteristics
Specifications for over-current release include applicable MCCB types and rated primary currents, with settings for various protective functions.
Let-Through Peak Current Characteristics
Charts and tables illustrate the maximum let-through peak current characteristics for various breaker models and voltage levels.
Discrimination and Selectivity
Discrimination is explained as the coordination of protective devices to ensure that only the device immediately upstream of a fault clears it, with tables indicating the level of discrimination between different breaker combinations.
Application Data
Guidance on reading discrimination tables and examples to achieve total discrimination in different scenarios are provided, along with the concept of cascading.
Introduction to Cascading
Cascading is a method where an upstream circuit breaker limits short-circuit currents, allowing downstream breakers with lower breaking capacities to interrupt the reduced current.
Accessories for TemBreak 2 MCCBs
Accessories include status and alarm contacts, remote tripping coils, and undervoltage protection coils, designed for easy installation and use.
Specifications
Specifications for MCCB components and accessories are detailed, including ratings for auxiliary and alarm switches, shunt and undervoltage trips.
Procedures
Remote tripping devices like Shunt Trip and Under Voltage Trip are discussed, with specific cable capacities and color codes.
Recommendations
Recommendations for motor operators and external operating handles for MCCBs are provided, emphasizing safety features.
Operating Mechanism and Handles
Details on the components and operation of a circuit breaker mounted inside a cubicle are provided, including locking devices and insulation accessories.
Dual Supply Changeover Systems
Interlocking accessories prevent multiple AC voltage sources from supplying a system simultaneously, with details on the TemTransfer Automatic Changeover Controller.
Installation
Various connection and mounting options for TemBreak 2 MCCBs are described, including front and rear connections and cable clamp terminals.
See more

Catalog excerpts

Tembreak 2-1

Innovators in Protection Technology The Ultimate Safety Breaker

 Open the catalog to page 1
Tembreak 2-2

All products supplied from this catalogue carry a guarantee against defects in materials and workmanship for a period of 12 months from date of purchase as standard. manufacture, sale and distribution of all products featured in this catalogue. Technical Support is Free We offer free technical support and application software to all customers. This could range from selecting a product for an unusual application through to carrying out a protection study. Please call one of the telephone numbers shown below. We have made ordering easy for you by colour coding the sections of this catalogue and...

 Open the catalog to page 2
Tembreak 2-3

Safety and protection are the prime purposes of Terasaki products. You care about safety and protection. The users of products you specify care about safety and protection. We call TemBreak 2 the Ultimate Safety Breaker. Throughout this catalogue you will see our Safety+ mark. This is designed to draw your attention to safety features which exceed international standards. Please read further to discover the benefits of TemBreak 2.

 Open the catalog to page 3
Tembreak 2-4

PRODUCT LINES MOULDED CASE CIRCUIT BREAKERS Rated current (7n) from 20A to 1600A. Breaking page 3 TemBreak The Ultimate Safety Breaker

 Open the catalog to page 4
Tembreak 2-5

TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 1600A 1. Welcome to TemBreak 2 • Easy Selection Guide • Safety Plus • Exceeding Standards • Reducing Environmental Impact 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions The Ultimate Safety Breaker

 Open the catalog to page 5
Tembreak 2-6

WELCOME TO TEMBREAK 2 EASY SELECTION GUIDE The TemBreak 2 range of products includes: - Moulded Case Circuit Breakers (MCCBs) - Switch-Disconnectors in the same compact moulded case frame sizes as MCCBs - A comprehensive range of accessories which are common to MCCBs and Switch-Disconnectors. All internal accessories are common to all frame sizes. Key to Model and Type Designations Model Denoted by Type Denoted by Low breaking capacity Medium breaking capacity High breaking capacity Extra High breaking capacity Fixed thermal, fixed or adjustable magnetic Adjustable thermal, adjustable magnetic...

 Open the catalog to page 6
Tembreak 2-7

EASY SELECTION GUIDE Frame Rating (A) MCCBs Model Switch-Disconnectors Model Note: All breaking capacities are r.m.s. symmetrical at 415V AC The Ultimate Safety Breaker

 Open the catalog to page 7
Tembreak 2-8

10 REASONS TO USE TEMBREAK 2 1. FIELD-INSTALLABLE ACCESSORIES • Accessories can be fitted by the switchboard builder or added by the end-user. • Handles and motor operators can be rapidly fitted using the locking pegs. It takes less than 10 seconds to secure a handle or motor to the MCCB – a great time saving compared to alternative products. • All accessories are endurance tested to the same level as the host MCCB. Locking Pegs 2. SAFETY LOCK FOR PLUG-IN VERSIONS The plug-in MCCB is locked to the base when the toggle is ON. It cannot be removed unless the toggle is OFF or TRIPPED. The safety...

 Open the catalog to page 8
Tembreak 2-9

6. COMPACT CHANGEOVERS The mechanical interlock is installed on the front of the MCCB, and is compatible with motor operators and handles. An automatic changeover system can be assembled very easily by a switchboard builder or end-user. Changeover Pair with Link Interlock and Motor Operators Viewed from Below (250A frame) 7. DIRECT OPENING Under the heading “Measures to minimise the risk in the event of failure”, IEC 60204-1 Safety of Machinery-Electrical Equipment of Machinery includes the following recommendation: “-the use of switching devices having positive (or direct) opening operation.”...

 Open the catalog to page 9
Tembreak 2-10

WELCOME TO TEMBREAK 2 SAFETY PLUS Terasaki have an innovative approach to product design. Our goal is to develop products which not only meet, but exceed recognised standards. We use our knowledge of related applications to improve circuit breaker designs. For instance, when developing the Direct Opening Action, we applied ideas from a machinery safety standard to the design of the TemBreak 2 switching mechanism. This proactive development policy confirms our reputation as Innovators in Protection Technology. Machine Safety Opening force is transmitted directly from the toggle switch Contacts...

 Open the catalog to page 10
Tembreak 2-11

SAFETY PLUS Visual Safety You can easily see if a breaker is open, closed or tripped. SAFETY+ coloured indicators boldly display the ON or OFF status. The indicators are fully covered if a breaker trips, and black is the only visible colour. This is a unique safety feature. You can identify faulty circuits at a glance. The toggle position always matches the position of the main contacts. Touch Safety The risk of touching live parts has been minimised by design. These features reduce the risk of touching live parts: • There are no exposed metal screws on the front face • IP20 protection at the...

 Open the catalog to page 11
Tembreak 2-12

WELCOME TO TEMBREAK 2 EXCEEDING STANDARDS Safety Plus TemBreak 2 MCCBs exceed the requirements of recognised standards. International Compliance • The TemBreak 2 MCCB complies with the international standard IEC 60947-2 • TemBreak 2 Switch Disconnectors comply with IEC 60947-3 • Accessories comply with IEC 60947-5-1 or IEC 61058-1 • The entire range conforms to the IEC general rules for switchgear, IEC 60947-1 • TemBreak 2 MCCBs comply with JIS C 8201-2-1 Ann.1 • The TemBreak 2 range complies with the EC Low Voltage Directive and all models are CE marked • TemBreak 2 MCCBs carry the IEC symbol...

 Open the catalog to page 12
Tembreak 2-13

REDUCING ENVIRONMENTAL IMPACT Longer Life Cycle It makes good environmental sense to install a product with a long life expectancy. If you install a TemBreak 2 MCCB, you can expect it to stay in service for at least 30,000 mechanical operations (250A Frame). This is 22,000 more operations than recommended by IEC 60947-2, the international standard for circuit breakers. If a system must be upgraded in future, we have made the following provisions for recycling: 1 The modular design of TemBreak 2 allows component parts and accessories to be easily disassembled and separately disposed of. Moulded...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.