TemPowerACBEconomical series A lineup from 630A to 1600A frame available

Open the catalog to page 1
TeamPowerACB Economical Series - 2

◆TemPower2 ◆TemPower2 products list Frame size (A) For AR-S Standard series and AR-H High fault series, please refer to the catalogue I55E. 1

Open the catalog to page 2
TeamPowerACB Economical Series - 3

1 Features TemPower2 economical series air circuit breakers excel in cost performance. TemPower2 economical series including 630A to 1600A frame breakers H:460 The breakers of this series are the same in enclosure size. Compact and fully equipped with essential functions, this series excels in cost performance. The ACB panel cutout identical for all the TemPower2 series breakers The same front panel cutout size for economical, standard, and high-fault series allows easy designing of switchboards. Increased accessibility from the front It enhances ease of installation, operation, and...

Open the catalog to page 3
TeamPowerACB Economical Series - 4

RATED CURRENT (max) [g(A)© 2 JIS®,IEC, EN, AS NEUTRAL POLE AMPERES FRAME (A) NUMBER OF POLES © RATED CURRENT OF OVER-CURRENT RELEASE [In](A) AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE [Ue](V. 50/60Hz) AC RATED BREAKING CAP [kA sym rms]/MAKING CAP [kA peak] JIS®, IEC, EN, AS AC 690V ® RATED IMPULSE WITHSTAND VOLTAGE [Ump](kV) CLOSING OPERATION TIME ©: Values in open air at 40°C. ©: Values with horizontal terminals. ®: 4poles ACBs without Neutral phases protection can not apply IT earthing system. ®: Contact TERASAKI for the details. ©: Comply with JIS C...

Open the catalog to page 4
TeamPowerACB Economical Series - 5

3 Specifications TemPower2 series ACBs have an extensive range of accessories available, enabling the ACBs to be “custom built” to suit every application. ACB type AR206E Economical Series Fixed type Horizontal terminals Vertical terminals Front connections Control circuit screw terminals Spring charged operation Over-current release Manual charging Electromagnetic Inst. Trip Device Motor charging Trip indicator O.C.R. Type AGR-12BL-AL LT, ST, INST Spring charge indicator Step-down transformer Operation indication (via single contact) Pre-trip alarm Spring charge indicator Trip indicator CT...

Open the catalog to page 5
TeamPowerACB Economical Series - 6

Fixed type This type of ACB has no draw-out cradle and is designed to be directly mounted in the switchboard. Terminal arrangements ■ Main circuit terminals The ACBs come standard with horizontal terminals. The user can change horizontal terminals to vertical or front terminals using optional attachments for any last minute alterations. £Horizontal terminals £Vertical terminals £Front connections ■ Control circuit terminals Control circuit terminals are front located to allow easy wiring/access. • The terminal blocks (for auxiliary switches and control circuits) are positioned on the top of...

Open the catalog to page 6
TeamPowerACB Economical Series - 7

Spring Charged Operation Manual charging type For this type of ACB, the closing springs are charged by means of the spring charging handle. ON/OFF operation of the ACB is performed by means of ON/OFF buttons on the ACB. ■ Charging the closing springs Pumping the spring charging handle by hand charges the closing springs. ■ Closing the ACB Pressing the ON button on the ACB closes the ACB. ■ Opening the ACB Pressing the OFF button on the ACB opens the ACB. The ACB cannot be closed as long as the OFF button is pressed. Motor charging type For this type of ACB, the closing springs are charged...

Open the catalog to page 7
TeamPowerACB Economical Series - 8

■ Operation power supply Applicable voltage range (V) CHARGE/ OFF operation Operation power supply ratings Motor inrush Motor steady-state Closing command current (peak) (A) current (A) current (peak) (A) Note 1: For the ratings refer to the shunt trip device of page 9. ^The split circuit between motor circuit and closing circuit is available as special specification. Contact us for the details. The maximum rated control voltage applicable to the operation power supply is AC240V. For higher voltages, a step-down transformer is needed. The following step-down transformers are available as...

Open the catalog to page 8
TeamPowerACB Economical Series - 9

Accessories for Spring Charged OperationSpring charge indicatorThis switch can be used to indicate that the closing springs have been fully charged. ■ Normal contacts for general service Minimum applicable load is DC24V 1mA.

Open the catalog to page 9
TeamPowerACB Economical Series - 10

[ Instantaneously-rated shunt trip device The instantaneously-rated shunt trip device allows the ACB to be opened when an external protection relay against overcurrent or reverse power is activated. Auxiliary switch 1C is used as the anti-burnout switch. This instantaneously-rated shunt trip can be fitted with undervoltage trip to the same ACB. (except DC 100V UVT) Shunt Trip Rating (Instantaneously-rated type) Rated Operational Max. excitation Opening time Type voltage voltage current (max.) Undervoltage trip device (UVT) The undervoltage trip device (UVT) trips the ACB when...

Open the catalog to page 10
TeamPowerACB Economical Series - 11

Over-current Releases (OCR) TemPower2 economical series are provided with the OCR, which can be operated with only two dials, one for selecting the rated current and the other for selecting a protection characteristic. Available characteristics include long time-delay trip, short time-delay trip, instantaneous trip, ground fault trip, pre-trip alarm (optional), and N-phase protection trip (optional). ©Ground fault trip function I GF| The peak value sensing is used (the residual current of each phase is detected). The GF pick-up current is set at 20% of the rated current [/n] with 0.2 sec....

Open the catalog to page 11
TeamPowerACB Economical Series - 12

■ Rated current [/n](A) Type Rated current (A): (/n) Protection characteristic Protective function Long time-delay trip Pick-up current (A) : (/r) (/n)X(0.4-0.5-0.63-0.8-0.85-0.9-0.95-1.0) • Non tripping when load current 5 ([Ir]X1 .05). • Tripping when ([/r]X1.05) < load current 5 ([/r]X1.2) Long time-delay trip Time-delay (s) : (tR) Time-delay setting tolerance ±20%, +150ms Short time-delay trip (/r)X Pick-up current (A) : (/sd) Short time-delay trip Time-delay (s) : (tsd) Instantaneous trip (/r)X Pick-up current (A) : (/) Pre-trip alarm Pick-up current (A) : (Ip) Time-delay (s)...

Open the catalog to page 12
TeamPowerACB Economical Series - 13

Other Accessories OCR test interface unit, type ANS2S OCR test interface unit ANS2S is a tool designed for checking the functionality of type AGR-12BL over-current release. Using this tool in conjunction with a commercially available relay tester allows easy on-site testing of the OCR. Be sure to use the OCR test interface unit in conjunction with a relay tester rated at 50A max. ■ Ratings and Specifications CT ratio Outline dimensions Mass ■ Prepare the following tools • OCR test interface unit, type ANS2S Do not disconnect the secondary terminal while the power is on. High voltage will be...