Humidity and temperature sensor Short description TSH206v3 is humidity and temperature sensor with a 1-Wire interface. The device integrates basic elements plus signals processing and provide a fully calibrated digital output. A unique capacitive element is used for measuring relative humidity while the temperature is measured by a band gap sensor. Both sensors are seamlessly coupled to a 12-bit analog to digital converter. This results in superior signal quality and fast response time. The sensor is delivered with one meter cable with RJ11 connectors. A 19” rack mount kit can be ordered separately. Server room and data centers monitoring. Humidity and temperature monitoring for facilities, vineyards, greenhouses, etc. Environmental quality monitoring and assessment. Humidity and temperature monitoring in building management systems. Technical parameters Parameter Operating Range Accuracy (max) Accuracy (max) Resolution Supply voltage (+VDD) Max consumption Ingress protection Head's dimensions Connectors Value Units Remark Value Units Remark 10 to 90* %RH non-condensing –20 to +60* °C ±3.0 %RH 20 to 80 %RH ±0.4 °C -10 to +60°C ±5.0 %RH 10 to 90 %RH ±1.0 °C -20 to +60°C 0.1 %RH 0.1 °C 4 to 5.5 VDC From 1-Wire bus 5 mA From 1-Wire bus IP20 85 x 35.1 x 23.5 mm Two RJ-11 in parallel * Recommended operating range is 20% to 80% RH (non-condensing) over -10°C to +60°C. Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time. Usage Can be used with following TERACOM controllers - TCW241
Open the catalog to page 1Description 1-Wire GND 1-Wire GND 1-Wire Data 1-Wire GND 1-Wire +VDD 1-Wire +VDD Corresponding UTP wires color White/Brown White/Green Green White/Orange Orange Brown status of the device is shown by single LED, located on the front panel: the LED blinks on period of 1 second, sensors works properly; the LED blinks on period of 3 seconds, there isn't communication with the controller; LED doesn't blink, there isn't power supply. Installation It is strongly recommended to use only UTP/FTP cables. It is strongly recommended to use daisychained (linear) topology for multiple sensors and keep...
Open the catalog to page 2All Teracom catalogs and technical brochures
-
Smoke detector TSS8030R
4 Pages
-
TSV100
2 Pages
-
TDI340
2 Pages
-
TSA200
2 Pages
-
TSV200-60i
2 Pages
-
TSC200-15
2 Pages
-
TSH202v3
2 Pages
-
TST100
2 Pages
-
TST103
2 Pages
-
TCW181B-CM
2 Pages
-
TCW280
2 Pages
-
TCW220
2 Pages
-
TCW210-TH
2 Pages
-
TSP200
2 Pages
-
TCW260
2 Pages