Product catalog summary
Overview: The TDI340 is an S0 pulse counter equipped with a MODBUS RTU interface. It features four isolated digital inputs compliant with the S0 standard 62053-31 and operates in both polling and edge modes. The device can count pulses on rising, falling, or both edges and provides simultaneous readings for digital input states.
Basic Features: The TDI340 includes an RS-485 interface supporting up to 63 nodes, non-volatile memory for counter storage, a wide supply voltage range starting from 5VDC, galvanically isolated inputs, 32-bit counters, a built-in 120 ohms termination resistor, and DIN rail mounting. Firmware updates can be performed via the interface.
Applications: The device is suitable for remote monitoring of electricity, water, and gas meters, industrial process control, remote data acquisition, and energy management. It can be used with energy monitoring modules like TCW260 and GSM-GPRS remote IO modules such as TCG140, as well as other third-party MODBUS RTU masters.
Specifications: The TDI340 operates within a supply voltage range of 5-36 VDC, with a maximum current of 25 mA at 5 VDC. It functions in temperatures from -20 to +60°C and relative humidity from 10 to 90% (non-condensing). It offers 1000 VDC functional isolation and has an ingress protection rating of IP 40. The dimensions are 35x86x59 mm, fitting a 2-module enclosure.
Supported Devices: The TDI340 is compatible with digital output devices and other S0 output devices, including electricity, heat, gas, and water meters.
See more

Catalog excerpts

TDI340-1

TDI340 S0 pulse counter with MODBUS RTU interface Overview TDI340 is а S0 pulse counter with the MODBUS RTU interface. It has 4 isolated digital inputs, complying with the S0 standard 62053-31. The S0 pulse counter works in polling or edge modes. In edge mode, it can be set up to count on rising, falling and both edges. The device is dedicated to the S0 pulse counter but it also provides simultaneous readings for the state of the digital inputs - OPEN/CLOSE. Independent delays for Low-To-High and High-To-Low transitions can be applied. The delays are from 0 to 656 seconds in 10mS step and work if the counter for the corresponding digital input is in polling mode. Applications • Remote monitoring of electricity meters; • Remote data acquisition; • Industrial process control; • Remote monitoring of gas meters; • Remote monitoring of water meters; • Energy management; • Monitoring of devices with S0 outputs; • Process monitoring. Basic features • RS-485 interface carrying up to 63 nods; • Non-volatile memory for counters storage; • Built-in 120 ohms termination resistor; • Wide supply voltage range, starting from 5VDC; • Galvanically isolated inputs; • Firmware update via the interface. Electricity Meters Heat Meters Water Meters Other S0 Digital outputs devices outputs devices Short specification Supply voltage, VDC Maximum current, mA Operating temperature range, °C Operating relative humidity range, %RH Isolation functional, VDC Ingress protection Dimensions, mm

 Open the catalog to page 1
TDI340-2

TERACOM TDI340 - SO Pulse counterApplications f TERACOM www.terswmsysteTO.cffm |w:o:u vtuj Jiatisj Energy Energy meter meter Energy Energy meter meter « ® e * Energy Energy meter meter Energy Energy meter meter « * 6 <f, • Energy monitoring module TCW260; • GSM-GPRS remote IO module TCG140; • Other third-party MODBUS RTU masters.

 Open the catalog to page 2

All Teracom catalogs and technical brochures

  1. TSV100

    2  Pages

  2. TSA200

    2  Pages

  3. TSV200-60i

    2  Pages

  4. TSC200-15

    2  Pages

  5. TSH202v3

    2  Pages

  6. TST100

    2  Pages

  7. TST103

    2  Pages

  8. TCW181B-CM

    2  Pages

  9. TCW280

    2  Pages

  10. TCW220

    2  Pages

  11. TCW210-TH

    2  Pages

  12. TSP200

    2  Pages

  13. TSH206

    2  Pages

  14. TCW260

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.