Energy monitoring module Overview TCW260 is an energy monitoring module with an Ethernet interface and data logger functionality. All its inputs are galvanically isolated from the power supply. The module has 4 digital inputs, S0 compatible. The digital inputs can work in ON/OFF or counter mode. There are also 6 analog inputs. Every analog input can work either in voltage (0/10V) or current loop (0/20mA) mode. The device supports the MODBUS RTU interface for Teracom and third-party sensors. The used RS-485 interface is fully isolated from the power supply. Ånergy monitoring and targeting for industry; Remote monitoring of renewable energy power plants; Protocol conversion - MODBUS RTU to MODBUS TCP; Water consumption analysis; Gas consumption optimization; Energy cost optimization systems; Energy consumption management systems; A building management system; Industrial processes monitoring; General SCADA systems. Interfaces 0/10V 0/20mA 100 Mbit Ethernet 4x Digital Isolated Inputs 6x Analog Isolated Inputs Basic features • Up to 24 channels for voltage/current or energy monitoring; • Periodical HTTP Post with XML/JSON files; • Up to 24 categorized alarms with flexible setup; • Data logger for 70000 records; • Graphs for monitored channels/alarms directly on the browser; • NTP support • 4 isolated digital inputs with S0 interface (EN62053-31); • HTTP API commands; • ON/OFF and counter modes for the digital inputs; • SNMP v.2 support; • 6 isolated analog inputs with 0/20mA or 0/10V modes; • Dynamic DNS support ; • RS-485 isolated interface for up to 24 MODBUS RTU registers; • Backup/Restore for device set

Open the catalog to page 1
TCW260 - 2

TCW260 Energy monitoring module Short specification Supply voltage, VDC Maximum current (without RS-485 powering), mA Weight, g Dimensions, mm Operating temperature range, °C Operating relative humidity range, %RH Isolation functional, VDC Maximum voltage applied to a digital input, V Maximum drop voltage between S0+ and S0-, V Maximum frequency for digital input in counter mode, Hz Analog inputs voltage range Analog inputs current loop ranges Analog inputs accuracy, % Typical application Energy meter Energy meter Internet HTTP POST HTTP POST Modbus RTU Sensor TC Monitor or other SCADA...

Open the catalog to page 2

All Teracom catalogs and technical brochures

  1. TSV100

    2 Pages

  2. TDI340

    2 Pages

  3. TSA200

    2 Pages

  4. TSV200-60i

    2 Pages

  5. TSC200-15

    2 Pages

  6. TSH202v3

    2 Pages

  7. TST100

    2 Pages

  8. TST103

    2 Pages

  9. TCW181B-CM

    2 Pages

  10. TCW280

    2 Pages

  11. TCW220

    2 Pages

  12. TCW210-TH

    2 Pages

  13. TSP200

    2 Pages

  14. TSH206

    2 Pages