TCW220
1 /2Pages

TCW220

TCW220
1 /2Pages

Catalog excerpts

TCW220-1

Ethernet data logger Overview TCW220 is an Ethernet data logger for general data acquisition applications. Its analog inputs, with 10-bit resolution, can be used for monitoring of 0-10 V and 4-20 mA sensors. Digital “dry contact” inputs can monitor discrete detectors – door sensor, smoke detector, AC voltage presence etc. TCW220 supports up to 8 TERACOM 1-Wire sensors for temperature, humidity, carbon dioxide, 0-20mA, AC/DC current, etc. The Ethernet data logger has 2 relays with normally open and normally closed contacts. All monitored parameters can be logged on a previous set time interval and/or on an alarm condition. In the internal nonvolatile memory can be stored up to 70000 records. The log file can be periodically uploaded to dedicated server by HTTP Post. Applications • Environmental monitoring – The device can monitor temperature, humidity, barometric pressure, CO2 etc. • Server room monitoring - The device can monitor AC power supply, smoke concentration, door opening, battery voltage, room temperature, and control the cooling system. • Industrial process automation – Monitoring of industrial sensors with 0-5V, 0-10V and 4-20mA output. • M2M systems - The device can send periodically information to monitoring server and execute its commands. • Data logging of facilities - The device can log and display the measured data. It can be used as a standalone device or as a part of SCADA system. Basic features • • • • • Data Logger for 70000 records; Graphical view of logged data; Automatic upload of logged data in CSV format; MODBUS/TCP support; SMTP support for e-mail alert SNMP v2 support with trap alert; HTTP Post service with API commands; XML/JSON status report files; Dynamic DNS support; Back-up/Restore of c

 Open the catalog to page 1
TCW220-2

TCW220 - Ethernet data logger Short specification Supply voltage, VDC Maximum current (with all relays ON), mA Weight, g Dimensions, mm Operating temperature range, °C Operating relative humidity range, %RH Supply voltage for 1-Wire bus (VDD), VDC Maximum output current for 1-Wire bus (VDD), A Analog inputs range, VDC Analog inputs resolution, VDC Analog inputs accuracy, % Maximum switchable relay current, À Maximum switchable relay voltage, VAC/VDC Typical application TCW220 TSH206 1-wire sensor Supported sensors and detectors A Temperature Barometric pressure AC/DC current Sensors with analog...

 Open the catalog to page 2

All Teracom catalogs and technical brochures

  1. TSV100

    2  Pages

  2. TDI340

    2  Pages

  3. TSA200

    2  Pages

  4. TSV200-60i

    2  Pages

  5. TSC200-15

    2  Pages

  6. TSH202v3

    2  Pages

  7. TST100

    2  Pages

  8. TST103

    2  Pages

  9. TCW181B-CM

    2  Pages

  10. TCW280

    2  Pages

  11. TCW210-TH

    2  Pages

  12. TSP200

    2  Pages

  13. TSH206

    2  Pages

  14. TCW260

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.