Thermal Engineering Solutions Petrochemical^ Thermocouples & RTD’s Ml Tube Skin Thermocouples Multipoint Thermocouples Thermowells Cables Pyrometers & Thermal Imagers ■ Calibration Equipments & Services ■ Heaters ■ Other Accessories TEMPSENS INSTRUMENTS www.tempsens.com
Open the catalog to page 1Pyrotech Group Pyrotech Controls India Pvt Lid Pyrotech Group Tempsens Instruments fl) Pvt Ltd U9II TEMPSENS Instruments (I) Pvt. Ltd is a part of Pyrotech group which was established by four technocrats in 1976 at Udaipur, with its first product as Thermocouples and RTDs. Today Tempsens is one of the largest & manufacturer of temperature sensors with world class manufacturing facilities in India, Germany and China. We are an ISO 9001:2008 certified company with NABL Accredited Laboratory. The company is involved into manufacturing of Thermocouples, RTDs, Thermowells, Cables, Non Contact Pyrometers,...
Open the catalog to page 2WELDING AND BRANZING Laser Welding (YAG) Programmable Micro Plasma Welding Machines TIG Welding machines with pulse modulation and rotary positioner Induction brazing Resistance Welding Brazing sets (Oxy-Acetative) MACHINING CNC turning centers VMC Machines Deep Hole drilling machines upto 1500mm drilling capacity Milling centers Manual Lathe machines Cutting machines Swaging Machines Laser Marking Machines Engraving Machines CABLE PLANT MACHINERY FEP/PFA Extrusion Lines PVC Extrusion Lines Silicon Extrusion Line Braiding Machines - High speed and regular Rewinding Machines Vertical Lapping Machines Stranding...
Open the catalog to page 3High accurate Thermocouples for variety of application : J, K, T, E, N (Base Metal) R, S, B (Noble Metal) : 0.25, 0.5, 1, 1.5, 3, 4.5, 6, 8 (mm), Others on request : 1.2, 1.6, 2, 2.5, 3.2 (mm), Others on request : SS304, SS321, SS316, SS310, HRS 446, INCONEL 600/800, Nickel, Hastalloy, Titanium, Ceramic 610 & C-799, Silicon Carbide, Monel etc. : Simplex/Duplex/Multipoints SPECIAL THERMOCOUPLES: • Squeezed Thermocouples with small tip dia • Trilevel Thermocouples • Coated Thermocouples (PTFE, Tungsten Carbide, Ceramic, Stellite etc.) • Thermocouple with IBRApproved Thermowells • High Temperature...
Open the catalog to page 4□ Different Types - Spring Loaded & Bimetal type □ Fully tailor made, can be offered with practically any length with varied MOC □ Ideal for measuring or controlling temperature at various elevations or zones in a vessel or reactor □ With a single pipe penetration, it enables several points to be read for a complete temperature profile and is constructed to withstand high temperature & pressure. □ Cost effective, overcome space limitations and data acquisition solution □ Construction enables user to remove thermocouple for maintenance □ Spring loaded for monitoring temperature profile, the spring clip...
Open the catalog to page 5• Basic thermocouple (normally type K, due to its optimum temperature range and cost factors) of diffrent OD with relatively higher sheath wall thickness (normally, 20 % of dia.) for longer usage life. • Mineral insulated (compact MgO 99.5 % purity) thermocouple is manufactured by cold drawing and annealing (heat treatment) process in controlled atmosphere. The heat treatment (which is controlled within +/- 2 Deg. C) is carried out in hydrogen atmosphere to avoid surface defects & partial oxidation of conductor. • Variety of sheath materials such as SS 310, HRS 446, Inconal600, lncoloy800orHastelloyXetc. •...
Open the catalog to page 6• Grind or scrub the surface of heater tube in the area of thermocouple junction location for removing scale and rust. Clean the area. • Clamp the thermocouple in the desired location. • Center of the wedge type pad must be ensured to be in contact with theheatertube. • Perform root weld pass on both sides of the pad using 1.6 mm dia. filler rod. Welds must overlap each other & run full length of the pad. • Perform secondary weld pass on both sides of the pad using 2.5 mm dia. filler rod. Welds to run full length of the pad. • Perform final weld pass on both sides of the pad using 2.5 mm dia....
Open the catalog to page 7Type Construction Process Connection : THERMOWELLS SS304, SS316, SS316L, SS321.SS310, HRS446, INCONEL 600/800,601, Hastalloy, Monel, Alloy20, Titanium etc Ceramics: KER 710 (C-799) (also with heavy wall thickness) Length: 350,530,600,650,740,900,1030,1200,1430 mm etc ODx ID: 24x18,20x15,15x10,12x8 HWT:24x12,20x8,15x6 Drilled Bar Stock, Fabricated Tapered, Straight Screwed, Flanged (SS316, HRS446, Hastalloy etc.) Solid/Coated Stellite Thermowell
Open the catalog to page 8Wide range of insulations and conductor configurations are manufactured in house by our cable manufacturing Facility. Compensating and Extension Cables for thermocouples J,K,T,E,N,R,S,B Types. RTD Cables in three wire & four wire configuration for simplex and six & eight wire for duplex are available. Wire Gauge Conductor Insulation 14 to 36 gauge (AWG/SWG) Solid / Multistrand Single and Double Fibre Glass, PTFE, Ceramic Fibre, Silica Fibre, SS Braided, PVC etc. Armored / Unarmored Other Cables for Signal, Control and Instrumentation are available with variety of insulation and various configurations...
Open the catalog to page 9RADIATION PYROMETERS: • Wide range of non contact pyrometers are available online applications for temperature range from-100... • Single Colour & Two Colour Pyrometers • Special MoltenAluminum Pyrometers • Fibre Optic Pyrometers • Portable Pyrometers-TCT 750, Tl 1500, Tl 2400 THERMAL IMAGERS: • ThermEye 160 :-20to350°C • ThermEye 160H: -20 to 600 °C CALIBRATION EQUIPMENT & SERVICES • Temperature Range: - 80 to 1700 Deg. C * Measuring instruments available with high accuracy • NABL accredited thermal calibration - Contact & Non-Contact from -196 to 1700 Deg. C • Fixed Point Cell Calibration TPW,...
Open the catalog to page 10• Calibration as per IEC 584/ANSI MC96.1 standard classl or2 • Insulation Resistance - Greater than 100 Mohms at room temperature & elevated • N2 Leakage Test • Response Time (63.2 % step change from ambient to 80 Deg. C) • Flame Test (to find out exact location of thermocouple in protection tube & to ensure touching of thermocouple tip to tube) • Continuity Test (no open junction in grounding & ungrounding construction) • Ductility (Bending Test) - min. bending radius hould be 5 times sheath OD • Sheath Integrity Test (Water Immersion Test) • Dye Penetration Test (for weld joints) • Helium LeakTest •...