Overview: The Temposonics® MH-Series COMPACT Analog/CANbus sensors are engineered for mobile machinery, providing reliable and precise position sensing. They are robust against electromagnetic interference, shock, vibration, dust, and weather, making them suitable for harsh environments.

Measurement Technology: These sensors use magnetostrictive technology, involving a ferromagnetic waveguide, a position magnet, and a strain pulse converter. The interaction of magnetic fields creates a torsional strain pulse, converted into an electrical signal for accurate and repeatable position determination.

Technical Specifications:

  • Stroke Length: 50 to 2500 mm
  • Resolution: Better than 0.1 mm
  • Operating Temperature: -40 to +105 °C
  • Ingress Protection: IP67/IP69K
  • Shock Resistance: 100 g (6 ms) single shock per axis
  • Vibration Resistance: 15 g (5-2000 Hz)
  • EMC Compliance: ISO 13766-1:2018, EN ISO 14982:2009, EN 13309:2010, ISO 16750-2:2012

Output Options:

  • Analog: Voltage (0.25-4.75 VDC/0.5-4.5 VDC) or Current (4-20 mA)
  • CANbus: SAE J1939, CANopen protocol

Electrical Connection: Sensors connect via M12 connectors, DT connector systems, or single wires, operating on 12/24 VDC with overvoltage and polarity reversal protection.

Mechanical Installation: Designed for in-cylinder use, with guidelines for position magnets and set screws to ensure functionality and environmental protection.

Applications: Ideal for agricultural and construction machinery, including steering systems and hydraulic units, replacing traditional contact-based sensors like potentiometers.

Connector Wiring and Cable Specifications: Wire lengths vary by connector type, with specific configurations for DT systems. Cable outlets range from 300 to 9900 mm.

Delivery and Accessories: Accessories like position magnets, O-rings, and backup rings are ordered separately. Options include M12 and DT connector systems.

Design and Order Codes: Sensor models feature pressure fit flange designs with specific rod diameters, dead zones, and stroke lengths. Order codes detail CANbus configurations.

Frequently Ordered Accessories: Position magnets come in various sizes and materials, with specific operating temperatures. Connector accessories include M12 flanges and DT retainers.

Cables and Wiring: M12 A-coded female connectors are available in straight and angled configurations, with material and length specifications.

Test Kits: Analog and CANbus test kits include testers, adapters, cables, and software licenses.

Contact Information: Temposonics has offices in the US, Germany, Italy, France, the UK, Scandinavia, China, and Japan, with regional contact details provided.

See more

Catalog excerpts

MH-Series COMPACT Analog/CANbus-1

MH-Series COMPACT Analog/CANbusMagnetostrictive Linear Position Sensors I Compact sensor housing I High reliability due to EMC, shock & vibration resistance

 Open the catalog to page 1
MH-Series COMPACT Analog/CANbus-2

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet MEASURING TECHNOLOGY Position magnet (Magnetic field) 2 The absolute, linear position sensors provided by Temposonics rely on the company’s proprietary magnetostrictive technology, which can determine position with a high level of precision and robustness. Each Temposonics® position sensor consists of a ferromagnetic waveguide, a position magnet, a strain pulse converter and supporting electronics. The magnet, connected to the object in motion in the application, generates a magnetic field at its location on the waveguide. A short current...

 Open the catalog to page 2
MH-Series COMPACT Analog/CANbus-3

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet */ Resonance frequencies excluded **/ According to calculations under use of the FKM guideline Dynamic pressure: > 2 x 106 pressure cycles 300 bar Static pressure: > 2 x 104 pressure cycles 400 bar Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar

 Open the catalog to page 3
MH-Series COMPACT Analog/CANbus-4

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet

 Open the catalog to page 4
MH-Series COMPACT Analog/CANbus-5

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet */ Resonance frequencies excluded **/ According to calculations under use of the FKM guideline Dynamic pressure: > 2 x 106 pressure cycles 300 bar Static pressure: > 2 x 104 pressure cycles 400 bar Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar

 Open the catalog to page 5
MH-Series COMPACT Analog/CANbus-6

Data Sheet Connection type M12 connector or DT connector system or single wires or cable outlet Operating voltage 12/24 VDC nominal (8...32 VDC) Max Inrush current 1.5 A/2 ms (1.0 A/2 ms if supply > 13 V) Supply voltage ripple < 1 % PP Over voltage protection (GND-VDC) Up to +36 VDC Polarity protection (GND-VDC) Up to -36 VDC Electric strength 500 VDC (DC GND to chassis GND)

 Open the catalog to page 6
MH-Series COMPACT Analog/CANbus-7

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet TECHNICAL DRAWING MS-D – Dead zone: 63.5 mm / Stroke length: 50…2500 mm Stroke length 50…2500 MS-F – Dead zone: 36.5 mm / Stroke length: 50…1200 mm Stroke length 50…1200 40.9 Controlling design dimensions are in millimeters Fig. 4: Temposonics® MH-Series COMPA

 Open the catalog to page 7
MH-Series COMPACT Analog/CANbus-8

Data Sheet • Single lead wires 0.22 mm2 • Attached A-coded M12 connector attached • Toolless assembly • Sealing IP67, up to IP69K with plugged mating connector Connector wiring M12 connector system (N...G) • Single lead wires 0.22 mm2 • Attached A-coded M12 connector attached • Toolless assembly • Sealing IP67, up to IP69K with plugged mating connector M12 connector system (N...H) • Single lead wires 0.22 mm2 • Attached A-coded M12 connector attached • Toolless assembly • Sealing IP67, up to IP69K with plugged mating connector Connector wiring Single wires pigtail (N...A) • Single lead wires...

 Open the catalog to page 8
MH-Series COMPACT Analog/CANbus-9

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet Pigtail cable (T…A) • TPE cable black 3 × 24 AWG (0.34mm2) • Ø 5 mm, non-shielded, 3 × 0.5 mm2 • Flexible, oil resistance Connector wiring 8 Single lead wires 0.22 mm2 Attached DT compatible connector Sealing IP69K (with or without mating connector) Wiring sequence controlled at sensor 2 Single lead wires 0.22 mm2 Attached DT compatible connector Sealing IP69K (with or without mating connector) Wiring sequence controlled at sensor 2 Connector wiring • Single lead wires 0.22 mm2 • Attached DT compatible connector • Sealing IP69K (with or...

 Open the catalog to page 9
MH-Series COMPACT Analog/CANbus-10

Data Sheet Single lead wires 0.22 mm2 Attached A-coded M12 connector attached Toolless assembly Sealing IP67, up to IP69K with plugged mating connector Connector wiring Single wires pigtail (N...A) • Single lead wires 0.5 mm2 Pigtail cable (T...A) • PUR cable, black DT connector system S (A...S) Single lead wires 0.22 mm2 Attached DT compatible connector Sealing IP69K (with or without mating connector) Wiring sequence controlled at sensor Connector wiring

 Open the catalog to page 10
MH-Series COMPACT Analog/CANbus-11

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet MECHANICAL INSTALLATION MECHANICAL INSTALLATION - POSITION MAGNET Magnet installation To Avoid sensor damage: • Do not select a screw with a sharp point • M5 or M4 screw (with flat or cup end) are typically used • For M5, ensure that the screw lands on the angled side of the set screw channel • Note: M5 screw may not seat completely into the set screw channel, but will properly retain the sensor M4 screw (with flat or cup end) will seat completely • It is recommended to seal the set screw cavity against water © Non-magnetic spacer © Position...

 Open the catalog to page 11
MH-Series COMPACT Analog/CANbus-12

Data Sheet • Position sensor Accessories (e.g. position • O-ring magnets) have to be ordered • Backup-ring separately • M12 connector system incl. M12 flange (when option selected) • DT connector system incl. connector assembly and retainer (when option selected) Manuals, Software & 3D models available at: www.temposonics.com

 Open the catalog to page 12
MH-Series COMPACT Analog/CANbus-13

Data Sheet Sensor model Examples wire length N06F = 60 mm Connector wiring: F: 2-3-4-5 Single wires 40.240 mm wire length (in 20 mm steps) Examples wire length N20A = 200 mm Cable outlet 300...9900 mm cable length (in 100 mm steps) Examples wire length T10A = 1000 mm 60.240 mm wire length (in 20 mm steps) Examples wire length N22S = 220 mm Connector wiring: 1-3-4-2 • Position sensor Accessories (e.g. position ^ • O-ring magnets) have to be ordered • Backup-ring separately • M12 connector system incl. M12 flange (when option selected) • DT connector system incl. connector assembly and retainer...

 Open the catalog to page 13
MH-Series COMPACT Analog/CANbus-14

Temposonics® MH-Series COMPACT Analog/CANbus Data Sheet FREQUENTLY ORDERED ACCESSORIES Position magnets Ø 32.8 Ring magnet OD17.4 Part no. 401 032 Ring magnet OD25.4 Part no. 400 533 Ring magnet OD33 Part no. 201 542-2 Material: PA neobond Weight: Approx. 5 g Surface pressure: Max. 20 N/mm2 Operating temperature: −40…+105 °C (−40…+221 °F) Material: PA ferrite Weight: Approx. 10 g Surface pressure: Max. 40 N/mm2 Operating temperature: −40…+120 °C (−40…+248 °F) Material: PA ferrite GF20 Weight: Approx. 14 g Surface pressure: Max. 40 N/mm2 Fastening torque for M4 screws: 1 Nm Operating temperature:...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.