Catalog excerpts

Types of autoclaves Technical data SteriDelta A Air+Steam Mixture Autoclaves MODEL These units are fitted with a ventilator system for mixing clean steam with air, which becomes the sterilization media. This process method should be recommended for complex plastic or glass containers such as pre-filled syringes or vials in which condensates may stagnant and be source of problems in the finish product. These autoclaves provide better drying finish thanks to the ventilator system and thus, products are downloaded ready for packing and labelling. Inner chamber dimmensions Width Height Depth mm mm mm Chamber Diameter Chamber capacity mm Total Volume litres Useful Volume litres Approx. load capacity (bottles DIN 500 ml Ø88 x H 153 mm) No. of rack units Door sliding motion units 1.000 1.614 2.067 1.000 1 396 horizontal SD 101019 1.000 1.000 1.900 1.614 3.909 1.900 2 792 horizontal SD 101028 1.000 1.000 2.800 1.614 5.771 2.800 3 1.188 1.000 1.250 1.900 1.801 4.865 2.375 2 1.188 horizontal SD 101228 1.000 1.250 2.800 1.801 7.182 3.500 3 1.782 horizontal SD 101237 1.000 1.250 3700 1.801 9.500 4.625 4 2.376 horizontal SD 121224 1.250 1.250 2.400 1.968 7.329 3.750 2 2.100 horizontal SD 121235 1.250 1.250 3.550 1.968 10.857 5.547 3 3.150 horizontal 1.250 1.250 4.700 1.968 14.385 7.344 4 4.200 horizontal 1.250 1.250 5.850 1.968 17.912 9.141 5 5.250 horizontal 1.250 1.250 7.000 1.968 21.440 10.938 6 6.300 horizontal SD 121535 1.250 1.500 3.550 2.139 16.993 6.656 3 3.675 horizontal SD 121547 1.250 1.500 4.700 2.139 16.993 8.813 4 4.900 horizontal SD 121558 1.250 1.500 5.850 2.139 21.161 10.969 5 6.125 horizontal SD 121570 1.250 1.500 7.000 2.139 25.328 13.125 6 7.350 horizontal SD 121581 1.250 1.500 8.150 2.139 29.496 15.281 7 8.575 horizontal SteriDelta horizontal SD 101219 SD 121270 Control systems 1.000 SD 121258 These units are fitted with a high flow recirculation system by a sanitary pump and heat exchanger that allows using (WFI) water as heat transfer media for heating up, sterilizing and cooling down the load. This process method provides faster cycles but containers come out damp. Anyhow, it is the preferred method in most cases due to its simplicity, economy and ease of validation. 1.000 SD 121247 SteriDelta W Superheated Water Rain Autoclaves SD 101010 Note: Other chamber sizes are available. Please contact sales.celester@telstar.eu for further information. Options and accessories Customised chambers according to existing loading accessories. Automatic loading/unloading system. Additional temperature probes. Additional channels in standard Chart recorder. Loading accessories: racks, pallets, trolleys, etc. The autoclave has a central control panel, which houses the PLC, signal conditioning units, safety circuits and general switchgear. The autoclave is fully managed through our SCADA system PharmaSter®. This control system includes an industrial PC with touch-sensitive colour display. The software allows not only for supervision and control of the process, but also compiling, storing and processing the whole information in a batch oriented mode. The system is fulfilling 21 CFR Part 11 guidelines. Headquarters Av. Font i Sagué, 55 08227 Terrassa (Spain) T. +34 937 361 600 F. +34 937 861 380 North America 1504 Grundy’s Lane Bristol, PA 19007 (USA) T. +1 215 826 0770 F. +1 215 826 0222 www.telstar-lifesciences.com 01 504 0411 I Telstar reserves the right to improvements and specifications changes without notice. Autoclaves with Cycles in Counterpressure
Open the catalog to page 1
General construction features Safety and Ergonomic Design for Users SteriDelta Durable Construction A choice of quality Telstar Celester represents nowadays one of the most advanced and quality alternatives worldwide in the field of sterilisation equipment under CGMP guidelines. Engineering and manufacturing practices follow ISO 9001 procedures, ASME BPE criteria, GAMP guidelines, etc. Design and construction meets the most stringent Regulations and Codes from Europe, USA and others concerning Safety and Pressure Vessels. To ensure the equipment meets your requirements, we work in...
Open the catalog to page 2
Types of autoclaves Technical data SteriDelta A Air+Steam Mixture Autoclaves MODEL These units are fitted with a ventilator system for mixing clean steam with air, which becomes the sterilization media. This process method should be recommended for complex plastic or glass containers such as pre-filled syringes or vials in which condensates may stagnant and be source of problems in the finish product. These autoclaves provide better drying finish thanks to the ventilator system and thus, products are downloaded ready for packing and labelling. Inner chamber dimmensions Width Height Depth mm...
Open the catalog to page 3
General construction features Safety and Ergonomic Design for Users SteriDelta Durable Construction A choice of quality Telstar Celester represents nowadays one of the most advanced and quality alternatives worldwide in the field of sterilisation equipment under CGMP guidelines. Engineering and manufacturing practices follow ISO 9001 procedures, ASME BPE criteria, GAMP guidelines, etc. Design and construction meets the most stringent Regulations and Codes from Europe, USA and others concerning Safety and Pressure Vessels. To ensure the equipment meets your requirements, we work in...
Open the catalog to page 4
General construction features Safety and Ergonomic Design for Users SteriDelta Durable Construction A choice of quality Telstar Celester represents nowadays one of the most advanced and quality alternatives worldwide in the field of sterilisation equipment under CGMP guidelines. Engineering and manufacturing practices follow ISO 9001 procedures, ASME BPE criteria, GAMP guidelines, etc. Design and construction meets the most stringent Regulations and Codes from Europe, USA and others concerning Safety and Pressure Vessels. To ensure the equipment meets your requirements, we work in...
Open the catalog to page 5
Types of autoclaves Technical data SteriDelta A Air+Steam Mixture Autoclaves MODEL These units are fitted with a ventilator system for mixing clean steam with air, which becomes the sterilization media. This process method should be recommended for complex plastic or glass containers such as pre-filled syringes or vials in which condensates may stagnant and be source of problems in the finish product. These autoclaves provide better drying finish thanks to the ventilator system and thus, products are downloaded ready for packing and labelling. Inner chamber dimmensions Width Height Depth mm...
Open the catalog to page 6All Telstar Technologies catalogs and technical brochures
-
SAS Pass Through Boxes
6 Pages
-
Air Showers
2 Pages
-
CAM
4 Pages
-
Fan Filter Units
1 Pages
-
CleanStar
1 Pages
-
OASYS Purified Water Systems
6 Pages
-
Pyromega
6 Pages
-
EtO Sterilization Systems
6 Pages
-
Sterimega
6 Pages
-
LyoSuite
2 Pages
-
Lyogistics
2 Pages
-
Lyonomic
6 Pages
-
Downflow Booths
6 Pages
-
Sterility Test Isolators
4 Pages
-
Aseptic Barrier Systems
6 Pages
-
Flexible Isolators
4 Pages
-
Slimline®
8 Pages
-
Lyomega
8 Pages
-
Containment barrier system
6 Pages
-
S4/S8
1 Pages
-
Bio II Advance
6 Pages
-
Water System
4 Pages
-
LyoQuest
4 Pages
-
LyoBeta
6 Pages
-
LyoAlfa 10/15
4 Pages
Archived catalogs
-
Laboratory Product Range
8 Pages