video corpo

EtO Sterilization Systems
6Pages

{{requestButtons}}

Catalog excerpts

EtO Sterilization Systems - 1

Safety is first and priority Product Range Model Telstar pays highest attention to safety issues and this is assured by fulfilling ATEX regulations. The ATEX regulation applies to any installation under a potentially explosive atmosphere and it is in force in Europe. In the USA the counterpart regulation is called NEC 500. A safety PLC is integrated for orchestrating control of the entire installation in accordance to regulations required to comply with the SIL classification. Moreover, Telstar’s cycle software programming recognises the flammability diagram for EtO mixtures, and avoids performing a recipe which has parameters that could result in an explosive mixture. Single Line Three different types of studies are carried out on each project: Hierarchy of Risks, Risks Analysis (HAZOP) and Failure Mode and Effect Analysis (FMEA), which enables Telstar to obtain the official ATEX certification (09ATEX0001X) from the notified body INERIS (France). SCADA Control System Dual Line SCADA Control System integrating the entire sterilization plant (comprised of all of the above modules or systems) located in a non-classified area. All authorized functions are accessible through the user interface. Actions posing a potential risk are controlled through an integrated PLC module, SIL certified, incorruptible and with restricted access. Parametrical Release Telstar can also provide a unique ATEX certified EtO IR detector, which is connected to the recirculation pipe and indicates the value of the chamber EtO concentration in a real time. Parametric release enables product to be released to the market based only on process records instead of the traditional biological indicator sterility test. This is advantageous in that it eliminates the routine costs associated with biological indicators and laboratory testing. Headquarters Av. Font i Sagué, 55 08227 Terrassa (Spain) T +34 937 361 600 F +34 937 861 380 BR-ETOSTERILIZATION-EN-0713 Telstar reserves the right to improvements and specifications changes without notice. No. 30 Jin Wen Road, Zhu Qiao Airport Ind. Zone, Nanhui District 201323 Shanghai, China T +86 21 58 093 731 F +86 21 58 092 857

Open the catalog to page 1
EtO Sterilization Systems - 2

Turnkey EtO plant delivery: the route to total solutions to the highest standards of safety and quality EtO Sterilization Systems Since 1992, Telstar has delivered industrial scale EtO (ethylene oxide) sterilization plants ATEX certified, fully documented with appropriate Factory Acceptance Tests, Installation/Operation Qualifications and so on. Telstar can offer a broad range of solutions and services; from cycle development to automatic loading/unloading systems, parametrical release, EtO monitoring system, and complete installation and commissioning of chambers, ancillary equipment and...

Open the catalog to page 2
EtO Sterilization Systems - 3

Turnkey EtO plant delivery: the route to total solutions to the highest standards of safety and quality EtO Sterilization Systems Since 1992, Telstar has delivered industrial scale EtO (ethylene oxide) sterilization plants ATEX certified, fully documented with appropriate Factory Acceptance Tests, Installation/Operation Qualifications and so on. Telstar can offer a broad range of solutions and services; from cycle development to automatic loading/unloading systems, parametrical release, EtO monitoring system, and complete installation and commissioning of chambers, ancillary equipment and...

Open the catalog to page 3
EtO Sterilization Systems - 4

Turnkey EtO plant delivery: the route to total solutions to the highest standards of safety and quality EtO Sterilization Systems Since 1992, Telstar has delivered industrial scale EtO (ethylene oxide) sterilization plants ATEX certified, fully documented with appropriate Factory Acceptance Tests, Installation/Operation Qualifications and so on. Telstar can offer a broad range of solutions and services; from cycle development to automatic loading/unloading systems, parametrical release, EtO monitoring system, and complete installation and commissioning of chambers, ancillary equipment and...

Open the catalog to page 4
EtO Sterilization Systems - 5

Safety is first and priority Product Range Model Telstar pays highest attention to safety issues and this is assured by fulfilling ATEX regulations. The ATEX regulation applies to any installation under a potentially explosive atmosphere and it is in force in Europe. In the USA the counterpart regulation is called NEC 500. A safety PLC is integrated for orchestrating control of the entire installation in accordance to regulations required to comply with the SIL classification. Moreover, Telstar’s cycle software programming recognises the flammability diagram for EtO mixtures, and avoids...

Open the catalog to page 5
EtO Sterilization Systems - 6

Safety is first and priority Product Range Model Telstar pays highest attention to safety issues and this is assured by fulfilling ATEX regulations. The ATEX regulation applies to any installation under a potentially explosive atmosphere and it is in force in Europe. In the USA the counterpart regulation is called NEC 500. A safety PLC is integrated for orchestrating control of the entire installation in accordance to regulations required to comply with the SIL classification. Moreover, Telstar’s cycle software programming recognises the flammability diagram for EtO mixtures, and avoids...

Open the catalog to page 6

All Telstar Technologies catalogs and technical brochures

  1. Air Showers

    2 Pages

  2. CAM

    4 Pages

  3. CleanStar

    1 Pages

  4. Pyromega

    6 Pages

  5. Sterimega

    6 Pages

  6. LyoSuite

    2 Pages

  7. Lyogistics

    2 Pages

  8. Lyonomic

    6 Pages

  9. Slimline®

    8 Pages

  10. Lyomega

    8 Pages

  11. S4/S8

    1 Pages

  12. Water System

    4 Pages

  13. SteriDelta

    6 Pages

  14. LyoQuest

    4 Pages

  15. LyoBeta

    6 Pages

Archived catalogs