This document provides detailed technical specifications, dimensions, accessories, and operational parameters for the S6R series DC switch disconnectors designed for photovoltaic (PV) and other DC applications. The devices comply with IEC 60947-1, IEC 60947-3, and UL98B standards, ensuring suitability for high-voltage DC systems up to 1500 Vdc.

Product Range and Ratings

  • Rated thermal current (Ith) ranges from 160 A to 400 A depending on the model.
  • Rated operational current (Ie) at 1500 Vdc matches the thermal current ratings: 160 A, 200 A, 250 A, 315 A, 320 A, and 400 A.
  • Rated insulation voltage (Ui) is 1500 Vdc across all models.
  • Rated impulse withstand voltage (Uimp) is 12 kV.
  • Short-circuit making capacity (Icm) and short-time withstand current (Icw) are both rated at 10 kA (peak and rms respectively) for 1 second.

Mechanical and Operational Features

  • Mechanical endurance is rated at 8000 cycles.
  • Switch-disconnectors are available in 1-pole (1P) and 2-pole (2P) configurations.
  • Terminals support copper busbars with cross-sectional areas and dimensions specified per model, including maximum length (L max), height (H max), and screw torque (M).
  • Mounting options include standard fixing and rotated front plate versions (available on request) to accommodate different installation requirements.

Dimensions and Accessories

  • Dimensions vary by model, with detailed measurements provided for height, length, and terminal sizes.
  • External handles are included with standard shafts (code DS-SA11), providing IP65 protection.
  • Shaft extensions are available in two types (DS-EP14 and DS-EP15) to accommodate door thickness variations.
  • Auxiliary contacts options include 1NO+1NC (code D5LAU01) and 2NO+2NC (code D5LAU02), rated for 16 A resistive and 4 A inductive loads at 250 Vac.

Standards and Certifications

  • Conforms to IEC 60947-1 and IEC 60947-3 standards.
  • UL98B certification for PV disconnect switches, suitable for use in photovoltaic systems per NEC Article 690.
  • Patent USA No. 9,899,159 B2 applies to the design.

Installation and Usage Recommendations

  • Consult manufacturer for grounded installation configurations.
  • Ensure correct shaft length and handle type are selected based on door thickness and mounting style.
  • Verify wiring capacity and busbar connection ranges according to model specifications.
  • Use appropriate auxiliary contacts for control and signaling functions.

Critical Parameters Summary Table

ModelRated Current (A)Voltage (Vdc)Ith (A)Ie (A)Icw (kA)Ui (V)Uimp (kV)Mechanical Cycles
S6R0160__S01601500160160101500128000
S6R0200__S02001500200200101500128000
S6R0250__S02501500250250101500128000
S6R0315__S03151500315315101500128000
S6R0400__D04001500400400101500128000

Summary

The S6R series DC switch disconnectors are robust, high-performance devices designed for safe disconnection in high-voltage DC applications such as photovoltaic systems. They offer a range of current ratings up to 400 A at 1500 Vdc, comply with international standards, and include versatile mounting and accessory options to suit various installation needs. Their mechanical durability and electrical ratings make them suitable for demanding industrial and renewable energy environments.

See more

Catalog excerpts

S6R DC-1

Switch - disconnector base mounting 1P - 2P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E Standard shaft included *(e1) L (mm) Door drilling for external handle Technical information CONSULT FOR GROUNDED INSTALLATIONS 160 A Rated insulation voltage (DC) Rated impulse withstand voltage Rated thermal current Ith in ambient at 40 ºC up to 80 ºC Rated short-circuit making capacity *(2) Icm Rated short-time withstand current (1sec) Mechanical features Number of mechanical operations (according to the standards, for other values please consult) For rotated mounting there are S6R references with front plate rotated (supply under request). Standard fixing Short - circuit behaviour *(1) Other voltages and / or utilization categories. Please consult Without limiting protective device (short-circuit maintained 50... 100 ms.) *(2) Terminals location Bottom view Bottom view Bottom view Bottom view Shaft extensions Rated operational current *(1) DC21B Bottom view Bottom view

 Open the catalog to page 1
S6R DC-2

Switch - disconnector for DC current 1P - 2P xternal handle  included shaft * E Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Standard shaft included *(e1) L (mm) Shaft extensions Door drilling for external handle Technical information CONSULT FOR GROUNDED INSTALLATIONS 250 Rated thermal current Rated operational current Rated short-time withstand current (0,05 sec) Icw Conforms to UL98B. Minus -20 to 50ºC. PV disconnect switch. Location Category B Suitable for use in PV Systems in accordance with Article 690 of the NEC Patent USA N.º 9,899,159  B2 Consult according to code Maximum...

 Open the catalog to page 2

All Telergon catalogs and technical brochures

  1. ATS

    8  Pages

  2. S5M DC

    3  Pages

  3. S6N DC

    2  Pages

  4. S6 DC

    4  Pages

  5. S5 DC

    5  Pages

  6. CIF22

    2  Pages

  7. series CTR

    7  Pages

  8. CCF CCP

    3  Pages

  9. S5F

    6  Pages

  10. CEC series

    2  Pages

  11. S6N AC

    2  Pages

  12. S5M AC

    4  Pages

  13. S6 AC

    2  Pages

  14. S5 AC

    9  Pages

  15. ZBK

    4  Pages

  16. CITA

    4  Pages

  17. CITP CTFR

    3  Pages

  18. TP T TB TF

    8  Pages

  19. Cam switches

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.