S6N AC

S6N AC

S6N AC

Product catalog summary

Overview

This document provides detailed technical specifications, accessories, and operational parameters for the S6N series of switch-disconnectors compliant with IEC / EN 60947-3 standards. The series covers devices rated from 250A up to 800A with various pole configurations (6P and 8P).

1. Product Description and Standards

  • Type: Switch-Disconnectors (O-I)
  • Standards: IEC / EN 60947-3
  • Mounting: Base mounting available in 6-pole (6P) and 8-pole (8P) versions

2. Electrical Ratings

Rated Current (A)250315400500630800
Rated Thermal Current (Ith) at 40ºC250315400500630800
Rated Insulation Voltage (Ui)1000 V
Rated Impulse Withstand Voltage (Uimp)12 kV
AC Rated Operational Current (Ie) at 400V (Triphasic)250-500 A (AC21A, AC22A, AC23A)630-800 A (AC21B, AC22B, AC23B)
Rated Breaking Capacity at 400V (cos φ=0.35-0.45)2000 - 3200 A2520 - 3200 A3200 A3200 A5040 A6400 A
Rated Making Capacity at 400V (cos φ=0.45)2500 - 4000 A3150 - 4000 A4000 A4000 A6300 A8000 A
Short-Circuit Making Capacity (Icm) Peak20 kA20 kA20 kA20 kA26 kA26 kA
Short-Time Withstand Current (Icw) 1 sec RMS12 kA12 kA12 kA12 kA16 kA16 kA

3. Mechanical Features

  • Number of mechanical operations: 8000 cycles for 250-500A models, 800 cycles for 630-800A models
  • Connection terminals support copper conductors with cross-sections up to 240 mm² (varies by model)
  • Terminal dimensions and torque specifications provided (e.g., M12 screws tightened to 24 N·m)

4. Auxiliary Contacts

  • Available configurations: 1NO+1NC (Code D5LAU01), 2NO+2NC (Code D5LAU02)
  • Rated current: 16 A for resistive loads, 4 A for inductive loads at 250 Vac

5. Safety and Locking Devices

  • Safety key lock devices available in simple and double versions (Codes DS-CA11, DS-CE11 for 250-500A; DS-CB21, DS-CF21 for 630-800A)
  • Key can lock handle in OFF position (optional ON position) and can only be removed when locked

6. Handles and Shafts

  • Direct handle (Codes DS-SI11 for 250-500A, DS-LI21 for 630-800A)
  • External handles with or without shafts, IP65 rated (Codes DS-SA14, DS-SA11, DS-SR11 for 250-500A; DS-LA24, DS-LA21, DS-LR21 for 630-800A)
  • Standard shafts included with length and pitch dimensions specified (e.g., 227 mm length for 250-500A, 195 mm for 630-800A)
  • Shaft extensions available in two types with codes DS-EP14, DS-EP15 (250-500A) and DS-EP23, DS-EP24 (630-800A)

7. Dimensions and Mounting

  • Detailed dimensional data provided for door drilling, handle installation, and shaft mounting
  • Dimensions include hole diameters (e.g., ø5.5 mm, ø12.5 mm), distances between mounting points, and overall device sizes

8. Notes and Recommendations

  • Other voltages and utilization categories available upon consultation
  • Short-circuit ratings assume no limiting protective device with short-circuit duration maintained between 50 to 100 ms
  • For mechanical operations beyond standard cycles, consult manufacturer

Summary

The S6N series switch-disconnectors offer robust electrical and mechanical performance for industrial applications requiring reliable switching and isolation up to 800A. The devices comply with international standards, provide high breaking and making capacities, and include a range of accessories for safety, operation, and installation flexibility.

See more

Catalog excerpts

S6N AC-1

Switch - disconnector base mounting 6P - 8P Auxiliary contacts Direct handle CODE External handle Safety key lock device without shaft Simple CODE DS-CA11 Double CODE DS-CE11 Emergency external handle S6N02506PS0 S6N02508PS0 Door drilling for handle and key lock device Simple Double Standard shaft included * Shaft extensions For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. CODE CODE Technical information Según IEC EN 60947-3 According /to IEC / EN 60947-3 250 315 400 500 Rated short-circuit making capacity * Door drilling for external handle Mechanical features Number of mechanical operations (according to the standards, for other values please consult) *(1) Other voltages and / or utilization categories. Please consult *(2) Without limiting protective device (short-circuit maintained 50... 100 ms.) Rated making capacity Rated breaking capacity Rated impulse withstand voltage Rated insulation voltage Ui Rated short-time withstand current (1 sec) Rated thermal current Ith 40º C in ambient at 50º C

 Open the catalog to page 1
S6N AC-2

Switch - disconnector base mounting 6P - 8P Direct handle CODE Auxiliary contacts External handle Safety key lock device without shaft Simple CODE DS-CB21 Double CODE DS-CF21 Emergency external handle Door drilling for handle and key lock device Simple Double Shafts Standard shaft included * Shaft extensions For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked External handle CODE CODE CODE Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Technical information According to IEC / EN 60947-3...

 Open the catalog to page 2

All Telergon catalogs and technical brochures

  1. ATS

    8  Pages

  2. S5M DC

    3  Pages

  3. S6R DC

    2  Pages

  4. S6N DC

    2  Pages

  5. S6 DC

    4  Pages

  6. S5 DC

    5  Pages

  7. CIF22

    2  Pages

  8. series CTR

    7  Pages

  9. CCF CCP

    3  Pages

  10. S5F

    6  Pages

  11. CEC series

    2  Pages

  12. S5M AC

    4  Pages

  13. S6 AC

    2  Pages

  14. S5 AC

    9  Pages

  15. ZBK

    4  Pages

  16. CITA

    4  Pages

  17. CITP CTFR

    3  Pages

  18. TP T TB TF

    8  Pages

  19. Cam switches

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.