Catalog excerpts

Switch - disconnector for DC current 4P + 4P Accessories irect handle D 1NO+1NC CODE DS-AU11 2NO+2NC CODE DS-AU12 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle included shaft * E Bridging links*(p1) A 500A CODE DS-PI230L (2 units) Standard shaft included *(e1) T o comply with the operation and electrical features, the bridging links must be assembled to the switch. Please consult. Rated thermal current Ith 40º C in ambient at 50º C Short - time withstand current (1 sec.) Icw Mechanical features Short - circuit behaviour Door drilling for external handle Rated insulation voltage DC20 Rated impulse withstand voltage Maximum weight (without jumpers) * Without limiting protective device (short-circuit maintained 50... 100 ms.) CONSULT FOR GROUNDED INSTALLATIONS Connection diagram Connection diagram Rated operational current DC21B Number of mechanical operations (according to the standards, for other values please consult) Front switch
Open the catalog to page 1
Switch - disconnector for DC current 4P + 4P Accessories uxiliary contacts A Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle included shaft * E *(p1) o comply with the operation and electrical features, T the bridging links must be assembled to the switch. Please consult. xternal handle without shaft E Standard shaft included *(e1) Technical information Short - circuit behaviour Short - time withstand current (1 sec.) Icw Mechanical features Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current DC21B Number of mechanical...
Open the catalog to page 2
Switch - disconnector for DC current 4P + 4P Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac xternal handle included shaft * E *(p1) o comply with the operation and electrical features, T the bridging links must be assembled to the switch. Please consult xternal handle without shaft E hafts S Standard shaft included *(e1) Technical information Rated thermal current Ith 40º C in ambient at 50º C Short - circuit behaviour Short - circuit making capacity *(2) Short - time withstand current (1 sec.) Icw Mechanical features Rated insulation voltage DC20 Rated impulse withstand...
Open the catalog to page 3All Telergon catalogs and technical brochures
-
ATS
8 Pages
-
S6R DC
2 Pages
-
S6N DC
2 Pages
-
S6 DC
4 Pages
-
S5 DC
5 Pages
-
CIF22
2 Pages
-
M21 M21 series
3 Pages
-
series CTR
7 Pages
-
CCF CCP
3 Pages
-
S5F
6 Pages
-
CEC series
2 Pages
-
CIS25 - A - C - D - F
6 Pages
-
S6N AC
2 Pages
-
S5M AC
4 Pages
-
S6 AC
2 Pages
-
S5 AC
9 Pages
-
ZBK
4 Pages
-
CITA
4 Pages
-
CITP CTFR
3 Pages
-
TP T TB TF
8 Pages
-
Enclosed solutions
3 Pages
-
Cam switches
17 Pages
-
Enclosed cam switches
18 Pages