S5F
1 /6Pages

S5F

S5F
1 /6Pages

Catalog excerpts

S5F-1

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Bridging links Safety key lock devices Simple CODE D5LCBB1 Double CODE D5LCFB1 For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked Auxiliary contacts Door drilling for handle and key lock device Simple Double Technical information consult Rated insulation voltage Rated impulse withstand voltage Rated breaking capacity Rated making capacity Rated thermal current Ith in ambient at 40º C AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Door drilling for external handle Short - circuit behaviour kA (peak) Short - time withstand current (1 sec.) Icw Number of mechanical operations (according to the standards, for other values please consult) Short - circuit making capacity *(2) Maximum weight (3/4 poles) * Other voltages and / or utilization categories. Please consult *(2) Without limiting protective device (short-circuit maintained 50 ms. - 100 ms.) (1) Also available 4P changeover switches under request, please consult There are versions of changeover switches without OFF 0 position: S5F (I - II) = S5D _ _ _ _ _ _ _ _, please consult Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. (1 kit for input or output) *(T) These accessories aren’t compatible with each other Standard shaft included *(e1) L (mm) Phase barrier*(T) (Only frontal side) Direct handle Changeover switch base mounting 3P - 3P+N Terminal shrouds*(T)

 Open the catalog to page 1
S5F-2

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal protection (1 unit for input or output) xternal handle  included shaft * E Terminal shrouds Shaft extension Standard shaft included *(e1) Bridging links Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Rated insulation voltage Rated impulse withstand voltage AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Rated breaking capacity Rated making capacity Rated thermal current Ith in ambient at 40º C Door drilling for external handle Short - circuit behaviour...

 Open the catalog to page 2
S5F-3

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal protection (1 unit for input or output) xternal handle  included shaft * E Shaft extension Bridging links Standard shaft included *(e1) Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Rated impulse withstand voltage AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Short - time withstand current (1 sec.) Icw Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (3/4 poles) Short - circuit behaviour...

 Open the catalog to page 3
S5F-4

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal protection (1 unit for input or output) xternal handle  included shaft * E Bridging links Standard shaft included *(e1) L (mm) Technical information Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Rated thermal current Ith in ambient at 40º C Rated breaking capacity Rated making capacity Rated insulation voltage Short - circuit behaviour Rated impulse withstand voltage AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Door drilling for external handle...

 Open the catalog to page 4
S5F-5

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal shrouds CODE Direct handle (1 kit for input or output, only front side) External handle Safety key lock device Simple CODE D5LCB41 Double CODE D5LCF41 Standard shaft included *(e1) L (mm) CODE CODE Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Auxiliary contacts For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked Shaft extensions Door drilling for handle and key lock device Simple...

 Open the catalog to page 5
S5F-6

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Direct handle External handle Standard shaft included *(e1) Shaft extensions Door drilling for handle and key lock device Simple Double For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked Simple CODE D5LCB41 Double CODE D5LCF41 Safety key lock device CODE CODE Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Technical information Rated breaking capacity Rated making capacity Rated insulation...

 Open the catalog to page 6

All Telergon catalogs and technical brochures

  1. ATS

    8  Pages

  2. S5M DC

    3  Pages

  3. S6R DC

    2  Pages

  4. S6N DC

    2  Pages

  5. S6 DC

    4  Pages

  6. S5 DC

    5  Pages

  7. CIF22

    2  Pages

  8. series CTR

    7  Pages

  9. CCF CCP

    3  Pages

  10. CEC series

    2  Pages

  11. S6N AC

    2  Pages

  12. S5M AC

    4  Pages

  13. S6 AC

    2  Pages

  14. S5 AC

    9  Pages

  15. ZBK

    4  Pages

  16. CITA

    4  Pages

  17. CITP CTFR

    3  Pages

  18. TP T TB TF

    8  Pages

  19. Cam switches

    17  Pages