S5F

S5F

S5F

Product catalog summary

Overview

This document provides detailed technical specifications, dimensions, accessories, and operational parameters for a series of base-mounted changeover switches compliant with IEC 60947-3 standards. The switches are available in multiple sizes and current ratings, with options for 3-pole (3P) and 3-pole plus neutral (3P+N) configurations. 4-pole (4P) versions are also available upon request.

Product Range and Sizes

  • Size 0: Rated currents 125A, 160A, 200A
  • Size 1: Rated currents 250A, 315A, 400A
  • Size 2: Rated currents 500A, 630A, 800A
  • Size 3: Rated currents 1000A, 1250A
  • Size 4: Rated currents 1600A, 1800A, 2000A
  • Size 5: Rated currents 2000A, 2500A, 3150A

Electrical Ratings and Performance

Each size category specifies the following key electrical parameters:

  • Rated Thermal Current (Ith): Ranges from 125A to 3150A depending on size.
  • Rated Breaking Capacity (400V AC22 or AC23): Varies from 375A to 9450A peak breaking current.
  • Rated Making Capacity (400V AC22 or AC23): Up to 10000A for larger sizes.
  • Short-Circuit Making Capacity (Icm): Peak values from 13kA to 100kA depending on size.
  • Short-Time Withstand Current (Icw): Typically 7kA to 50kA rms for 1 second.
  • Rated Insulation Voltage (Ui): 1000V across all sizes.
  • Rated Impulse Withstand Voltage (Uimp): 8kV to 12kV depending on size.
  • Operational Current (Ie) at 400V: Specified for utilization categories AC21A, AC22A, and AC23A.

Mechanical and Operational Characteristics

  • Number of Mechanical Operations: Typically 3000 to 8000 cycles depending on size and model.
  • Maximum Weight: Ranges from approximately 1.8 kg for smaller sizes to over 42 kg for the largest models.
  • Terminal and Mounting Dimensions: Detailed dimensions provided for shaft lengths, shaft extensions, mounting holes, and terminal sizes.

Accessories and Options

  • Handles: Direct handles and external handles with shafts are available, including IP65 rated external handles.
  • Safety Key Lock Devices: Simple and double key lock options for handle locking in OFF or ON positions, with key removal only when locked.
  • Auxiliary Contacts: Available in configurations 1NO+1NC and 2NO+2NC, rated for 16A resistive and 4A inductive loads at 250Vac.
  • Terminal Shrouds and Phase Barriers: Various kits for terminal protection and phase segregation, noting some accessories are incompatible with each other.
  • Bridging Links: Provided for linking poles, with codes specified per size.
  • Shaft Extensions: Multiple shaft extension types and lengths available for different sizes.

Installation and Mounting

  • Detailed door drilling dimensions for external handle and key lock device installation are provided for each size.
  • Standard shafts are included with each switch; extensions can be ordered separately.

Special Versions

  • Versions without an OFF (0) position are available under the S5D series designation; consultation is required for these models.
  • 4-pole versions are available on request.

Standards Compliance

All changeover switches comply with IEC 60947-3 standards, ensuring safety, reliability, and compatibility with industrial electrical systems.

Critical Parameters and Limitations

  • Short-circuit making capacity tests assume no limiting protective device and short-circuit duration maintained between 50 ms and 100 ms.
  • Operational current ratings are specified for 50/60 Hz frequency; other voltages or utilization categories require consultation.
  • Some accessories are not compatible with each other and must be selected accordingly.

Summary

This document serves as a comprehensive technical reference for selecting, installing, and accessorizing a wide range of motorized base-mounted changeover switches. It covers electrical and mechanical specifications, accessory options, and installation guidelines for sizes ranging from 125A to 3150A, ensuring suitability for various industrial applications requiring reliable switching and isolation.

See more

Catalog excerpts

S5F-1

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Bridging links Safety key lock devices Simple CODE D5LCBB1 Double CODE D5LCFB1 For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked Auxiliary contacts Door drilling for handle and key lock device Simple Double Technical information consult Rated insulation voltage Rated impulse withstand voltage Rated breaking capacity Rated making capacity Rated thermal current Ith in ambient at 40º C AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Door drilling for external handle Short - circuit behaviour kA (peak) Short - time withstand current (1 sec.) Icw Number of mechanical operations (according to the standards, for other values please consult) Short - circuit making capacity *(2) Maximum weight (3/4 poles) * Other voltages and / or utilization categories. Please consult *(2) Without limiting protective device (short-circuit maintained 50 ms. - 100 ms.) (1) Also available 4P changeover switches under request, please consult There are versions of changeover switches without OFF 0 position: S5F (I - II) = S5D _ _ _ _ _ _ _ _, please consult Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. (1 kit for input or output) *(T) These accessories aren’t compatible with each other Standard shaft included *(e1) L (mm) Phase barrier*(T) (Only frontal side) Direct handle Changeover switch base mounting 3P - 3P+N Terminal shrouds*(T)

 Open the catalog to page 1
S5F-2

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal protection (1 unit for input or output) xternal handle  included shaft * E Terminal shrouds Shaft extension Standard shaft included *(e1) Bridging links Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Rated insulation voltage Rated impulse withstand voltage AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Rated breaking capacity Rated making capacity Rated thermal current Ith in ambient at 40º C Door drilling for external handle Short - circuit behaviour...

 Open the catalog to page 2
S5F-3

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal protection (1 unit for input or output) xternal handle  included shaft * E Shaft extension Bridging links Standard shaft included *(e1) Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Rated impulse withstand voltage AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Short - time withstand current (1 sec.) Icw Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (3/4 poles) Short - circuit behaviour...

 Open the catalog to page 3
S5F-4

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal protection (1 unit for input or output) xternal handle  included shaft * E Bridging links Standard shaft included *(e1) L (mm) Technical information Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Rated thermal current Ith in ambient at 40º C Rated breaking capacity Rated making capacity Rated insulation voltage Short - circuit behaviour Rated impulse withstand voltage AC Rated operational current *(1) (Rated operational frequency 50 / 60 Hz) Door drilling for external handle...

 Open the catalog to page 4
S5F-5

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Terminal shrouds CODE Direct handle (1 kit for input or output, only front side) External handle Safety key lock device Simple CODE D5LCB41 Double CODE D5LCF41 Standard shaft included *(e1) L (mm) CODE CODE Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Auxiliary contacts For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked Shaft extensions Door drilling for handle and key lock device Simple...

 Open the catalog to page 5
S5F-6

CHANGEOVER SWITCHES I-O-II CHANGEOVER SWITCHES I-O-II Changeover switch base mounting 3P - 3P+N Direct handle External handle Standard shaft included *(e1) Shaft extensions Door drilling for handle and key lock device Simple Double For external handle, lock the handle by means of a key in position “OFF” (under request, in “ON”), the key can only be removed with the handle locked Simple CODE D5LCB41 Double CODE D5LCF41 Safety key lock device CODE CODE Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. Technical information Rated breaking capacity Rated making capacity Rated insulation...

 Open the catalog to page 6

All Telergon catalogs and technical brochures

  1. ATS

    8  Pages

  2. S5M DC

    3  Pages

  3. S6R DC

    2  Pages

  4. S6N DC

    2  Pages

  5. S6 DC

    4  Pages

  6. S5 DC

    5  Pages

  7. CIF22

    2  Pages

  8. series CTR

    7  Pages

  9. CCF CCP

    3  Pages

  10. CEC series

    2  Pages

  11. S6N AC

    2  Pages

  12. S5M AC

    4  Pages

  13. S6 AC

    2  Pages

  14. S5 AC

    9  Pages

  15. ZBK

    4  Pages

  16. CITA