S5 DC

S5 DC

S5 DC

Product catalog summary
Overview: This document provides technical specifications and details for a series of switch-disconnectors designed for DC current applications. The document is structured into different sections based on the size and capacity of the switch-disconnectors, ranging from 100A to 3150A.
Specifications:
  • Rated Thermal Current: The switch-disconnectors are rated for various thermal currents at different ambient temperatures (40ºC, 50ºC, 60ºC) with capacities ranging from 100A to 3150A.
  • Rated Insulation Voltage: All models have a rated insulation voltage of 1500 V DC.
  • Rated Impulse Withstand Voltage: The impulse withstand voltage is consistent across models at 8 kV or 12 kV depending on the size.
  • Short-Circuit Behavior: The short-circuit making capacity varies, with peak values ranging from 20 kA to 75 kA, and short-time withstand current (1 sec) ranging from 12 kA to 50 kA.
  • Mechanical Operations: The number of mechanical operations varies by model, with cycles ranging from 600 to 10,000.
Procedures and Standards:
  • The switch-disconnectors comply with IEC 60947-1 and IEC 60947-3 standards.
  • Installation requires specific bridging links to ensure compliance with operational and electrical features.
Accessories and Additional Features:
  • Various handle options are available, including direct and external handles with IP65 protection.
  • Auxiliary contacts are available in configurations of 1NO+1NC and 2NO+2NC, suitable for resistive and inductive loads.
  • Shaft extensions and terminal shrouds are provided for different configurations and sizes.
Recommendations:
  • Consultation is advised for installations requiring grounding and for specific operational categories not covered in the document.
  • Ensure proper assembly of bridging links to maintain compliance with electrical features.
See more

Catalog excerpts

S5 DC-1

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E (1 unit for input or output) xternal handle  without shaft E erminal shrouds (2 units)  T A Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (without bridging links) Door drilling for external handle *(p1) o comply with the operation and electrical features, T the bridging links must be assembled to the switch. Please consult. *(1) Other voltages and / or utilization categories. Please consult *(2) Without limiting protective device (short-circuit maintained 50... 100 ms.) Connection diagram Terminal shrouds CONSULT FOR GROUNDED INSTALLATIONS Short - circuit behaviour Rated thermal current Ith 40º C in ambient at 50º C Connection diagram Shaft extensions Technical information Rated operational current *(1) DC21B

 Open the catalog to page 1
S5 DC-2

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E input or output) (1 unit for xternal handle  without shaft E erminal shrouds  (2 units - only for 500A)) T A Short - circuit behaviour Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Maximum weight (without bridging links) Number of mechanical operations (according to the standards, for...

 Open the catalog to page 2
S5 DC-3

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E erminal shrouds  (2 units - only for 850A) T xternal handle  without shaft E Technical information Standard shaft included *(e1) Rated thermal current Ith 40º C in ambient at 50º C Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Number of mechanical operations (according to the standards,...

 Open the catalog to page 3
S5 DC-4

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E xternal handle  without shaft E erminal shrouds (2 units) T Standard shaft included *(e1) Technical information Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (without jumpers)...

 Open the catalog to page 4
S5 DC-5

Switch - disconnector for DC current 4P+4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac xternal handle  included shaft * E xternal handle  without shaft E Standard shaft included *(e1) L (mm) Technical information *(p1) comply with the operation and electrical features, To the bridging links must be assembled to the switch. Please consult Rated thermal current Ith 40º C in ambient at 50º C Short - circuit behaviour Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Mechanical features Maximum weight (without...

 Open the catalog to page 5

All Telergon catalogs and technical brochures

  1. ATS

    8  Pages

  2. S5M DC

    3  Pages

  3. S6R DC

    2  Pages

  4. S6N DC

    2  Pages

  5. S6 DC

    4  Pages

  6. CIF22

    2  Pages

  7. series CTR

    7  Pages

  8. CCF CCP

    3  Pages

  9. S5F

    6  Pages

  10. CEC series

    2  Pages

  11. S6N AC

    2  Pages

  12. S5M AC

    4  Pages

  13. S6 AC

    2  Pages

  14. S5 AC

    9  Pages

  15. ZBK

    4  Pages

  16. CITA

    4  Pages

  17. CITP CTFR

    3  Pages

  18. TP T TB TF

    8  Pages

  19. Cam switches

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.