Switch - disconnector for DC current 4P 1NO+1NC CODE D5LAU01 2NO+2NC CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle included shaft * E (1 unit for input or output) xternal handle without shaft E erminal shrouds (2 units) T A Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (without bridging links) Door drilling for external handle *(p1) o comply with the operation and electrical features, T the bridging links must be assembled to the switch. Please consult. *(1) Other voltages and / or utilization categories. Please consult *(2) Without limiting protective device (short-circuit maintained 50... 100 ms.) Connection diagram Terminal shrouds CONSULT FOR GROUNDED INSTALLATIONS Short - circuit behaviour Rated thermal current Ith 40º C in ambient at 50º C Connection diagram Shaft extensions Technical information Rated operational current *(1) DC21B
Open the catalog to page 1Switch - disconnector for DC current 4P 1NO+1NC CODE D5LAU01 2NO+2NC CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle included shaft * E input or output) (1 unit for xternal handle without shaft E erminal shrouds (2 units - only for 500A)) T A Short - circuit behaviour Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Maximum weight (without bridging links) Number of mechanical operations (according to the standards, for...
Open the catalog to page 2Switch - disconnector for DC current 4P 1NO+1NC CODE D5LAU01 2NO+2NC CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle included shaft * E erminal shrouds (2 units - only for 850A) T xternal handle without shaft E Technical information Standard shaft included *(e1) Rated thermal current Ith 40º C in ambient at 50º C Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Number of mechanical operations (according to the standards,...
Open the catalog to page 3Switch - disconnector for DC current 4P 1NO+1NC CODE D5LAU01 2NO+2NC CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle included shaft * E xternal handle without shaft E erminal shrouds (2 units) T Standard shaft included *(e1) Technical information Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (without jumpers)...
Open the catalog to page 4Switch - disconnector for DC current 4P+4P 1NO+1NC CODE D5LAU01 2NO+2NC CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac xternal handle included shaft * E xternal handle without shaft E Standard shaft included *(e1) L (mm) Technical information *(p1) comply with the operation and electrical features, To the bridging links must be assembled to the switch. Please consult Rated thermal current Ith 40º C in ambient at 50º C Short - circuit behaviour Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Mechanical features Maximum weight (without...