S5 DC-1

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E (1 unit for input or output) xternal handle  without shaft E erminal shrouds (2 units)  T A Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (without bridging links) Door drilling for external handle *(p1) o comply with the operation and electrical features, T the bridging links must be assembled to the switch. Please consult. *(1) Other voltages and / or utilization categories. Please consult *(2) Without limiting protective device (short-circuit maintained 50... 100 ms.) Connection diagram Terminal shrouds CONSULT FOR GROUNDED INSTALLATIONS Short - circuit behaviour Rated thermal current Ith 40º C in ambient at 50º C Connection diagram Shaft extensions Technical information Rated operational current *(1) DC21B

 Open the catalog to page 1
S5 DC-2

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E input or output) (1 unit for xternal handle  without shaft E erminal shrouds  (2 units - only for 500A)) T A Short - circuit behaviour Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Maximum weight (without bridging links) Number of mechanical operations (according to the standards, for...

 Open the catalog to page 2
S5 DC-3

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E erminal shrouds  (2 units - only for 850A) T xternal handle  without shaft E Technical information Standard shaft included *(e1) Rated thermal current Ith 40º C in ambient at 50º C Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Number of mechanical operations (according to the standards,...

 Open the catalog to page 3
S5 DC-4

Switch - disconnector for DC current 4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac. xternal handle  included shaft * E xternal handle  without shaft E erminal shrouds (2 units) T Standard shaft included *(e1) Technical information Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Rated insulation voltage DC20 Rated impulse withstand voltage Rated operational current *(1) DC21B Number of mechanical operations (according to the standards, for other values please consult) Maximum weight (without jumpers)...

 Open the catalog to page 4
S5 DC-5

Switch - disconnector for DC current 4P+4P 1NO+1NC  CODE D5LAU01 2NO+2NC  CODE D5LAU02 Ie = 16 A (resistive loads) 4 A (inductive loads) at 250 Vac xternal handle  included shaft * E xternal handle  without shaft E Standard shaft included *(e1) L (mm) Technical information *(p1) comply with the operation and electrical features, To the bridging links must be assembled to the switch. Please consult Rated thermal current Ith 40º C in ambient at 50º C Short - circuit behaviour Short - circuit making capacity *(2) Rated short-time withstand current (1sec.) Mechanical features Maximum weight (without...

 Open the catalog to page 5

All Telergon catalogs and technical brochures

  1. ATS

    8  Pages

  2. S5M DC

    3  Pages

  3. S6R DC

    2  Pages

  4. S6N DC

    2  Pages

  5. S6 DC

    4  Pages

  6. CIF22

    2  Pages

  7. series CTR

    7  Pages

  8. CCF CCP

    3  Pages

  9. S5F

    6  Pages

  10. CEC series

    2  Pages

  11. S6N AC

    2  Pages

  12. S5M AC

    4  Pages

  13. S6 AC

    2  Pages

  14. S5 AC

    9  Pages

  15. ZBK

    4  Pages

  16. CITA

    4  Pages

  17. CITP CTFR

    3  Pages

  18. TP T TB TF

    8  Pages

  19. Cam switches

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.