Overview: The document provides comprehensive technical specifications for various models of enclosed cam switches, including the CITP, CITR, CTFR, CITA, and CITC series. These switches are designed for industrial use and come in plastic and metallic enclosures with protection ratings of IP65 and IP55, respectively.
Specifications: The cam switches are available in configurations from 1 to 4 poles, handling currents from 12A to 315A, depending on the model. They comply with IEC 60947-3 standards, ensuring reliability and safety. The switches operate at a rated insulation voltage of up to 1000V and can withstand impulse voltages up to 8kV.
Technical Details: The document details the rated thermal current (Ith), rated insulation voltage (Ui), rated impulse withstand voltage (Uimp), and AC rated operational current (Ie) for different utilization categories (AC21A, AC22A, AC23A). It also specifies the rated conditional short-circuit current, rated maximum current, and rated breaking capacity for each model.
Mechanical and Environmental Conditions: The switches are designed for mechanical durability of up to 10,000 operations. They are suitable for environments with temperatures from -5°C to +40°C, altitudes up to 2000 meters, and humidity up to 90%. The pollution degree is rated at 3, standard for industrial applications.
Additional Features: The switches can be equipped with padlockable handles upon request, and customization of diagrams and schemes is possible. Dimensions and installation details for each model are provided.
Company Information: The document includes contact information and descriptions of companies within the Gorlan Group, such as Inaselec, Plastibor, and Pronutec, highlighting their roles in manufacturing and distributing electrical components.
Technical Specifications:
1. Mechanical Durability: 8000 to 10000 operations, depending on the model.
2. Conductor Specifications: Rigid and flexible copper conductors range from 2x2.5 mm² to 185 mm².
3. Service Conditions: Ambient temperature ranges from -5ºC to +40ºC, with a maximum altitude of 2000 m and humidity up to 90%. Pollution degree is 3.
4. Electrical Ratings: Rated frequency is 50/60 Hz. Rated duties for AC21A, AC22A, and AC23A categories are continuous for 8 hours.
Product Series and Ratings:
1. Enclosed Changeover Switches: Available in IP65 and IP55 enclosures, sizes 0 to 3.
2. Rated Thermal Current (Ith): 16 A to 315 A.
3. Rated Insulation Voltage (Ui): 500 V to 1000 V.
4. Rated Impulse Withstand Voltage (Uimp): 6 kV to 8 kV.
5. AC Rated Operational Current (Ie): Varies by category and voltage.
6. Short-Circuit Ratings: Conditional short-circuit current is 10 kA to 15 kA.
Maintenance Recommendations:
1. Regular inspections to ensure components are in good condition.
2. Check operability of switches after incidents or during maintenance.
3. Tightening torque of electrical connections should be checked.
4. Use appropriate personal protective equipment when working on live components.
Warranty and Safety:
1. Products are warranted for 2 years against manufacturing defects.
2. Warranty covers repair or replacement of defective goods but excludes misuse or tampering.
3. Safety precautions must be observed to prevent accidents and injuries.
Additional Information:
1. Products comply with IEC 60947-3 standards.
2. For specific handle colors or configurations, consultation is required.
3. Technical data is subject to change; refer to the manufacturer's website for updates.
See more

Catalog excerpts

Enclosed cam switches-2

[email protected] www.tripus.de [email protected] www.pronutec.com Parque Empresarial Boroa, Parcela 2C-1 48340 Amorebieta, Vizcaya-Spain Tel.: (+34) 94 605 24 62 [email protected] www.merytronic.com Am Hohen Rain 2 89347 Bubesheim Tel: (+ 49) 8221 9016-0 Fax: (+ 49) 8221 3073 Pronutec GmbH. After many years of experience in the German market, Pronutec GmbH was established to provide customers a more personalized and direct service. Merytronic is a company with a high added value in research, development and production of electronic equipment, both fixed and portable, for monitoring, control...

 Open the catalog to page 2
Enclosed cam switches-3

CITP CTFR Arrow handle Chambers Padlockable handle Technical information According to IEC 60947-3 Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum altitude: 2.000 m. Maximum humidity: 90%. Pollution degree: 3 (standard for industrial applications). Rated frecuency at AC utilization categories:...

 Open the catalog to page 3
Enclosed cam switches-4

Arrow handle CITP CITR Padlockable handle Technical information Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum altitude: 2.000 m. Maximum humidity: 90%. Pollution degree: 3 (standard for industrial applications). Rated frecuency at AC utilization categories: 50/60 Hz. R ated duties at utilization categories AC21A, AC22A and AC23A: Continuing (8 hours); uninterrupted. Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards,...

 Open the catalog to page 4
Enclosed cam switches-5

Padlockable handle Chambers Technical information According to IEC 60947-3 AC rated operational current Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor Rated thermal current Rated insulation voltage Rated impulse withstand voltage *(1) With terminals for connection 120 Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum altitude: 2.000...

 Open the catalog to page 5
Enclosed cam switches-6

(metallic enclosure - aluminium) 1P up to 4P Arrow handle Chambers Padlockable handle Technical information According to IEC 60947-3 Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor AC rated operational current Rated thermal current Rated insulation voltage Rated impulse withstand voltage Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum...

 Open the catalog to page 6
Enclosed cam switches-7

(metallic enclosure - aluminium) 1P up to 4P Arrow handle Chambers Padlockable handle Technical information According to IEC 60947-3 Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor AC rated operational current Rated thermal current Rated insulation voltage Rated impulse withstand voltage Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum...

 Open the catalog to page 7
Enclosed cam switches-8

CITA CITC Arrow handle Chambers Padlockable handle *(1) With terminals for connection *(2) Mounting without connection terminals or terminals + phase barriers Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum altitude: 2.000 m. Maximum humidity: 90%. Pollution degree: 3 (standard for industrial applications). Rated frecuency at AC utilization categories: 50/60 Hz. R ated duties at utilization categories AC21A, AC22A and AC23A: Continuing (8 hours); uninterrupted. Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45...

 Open the catalog to page 8
Enclosed cam switches-9

(metallic enclosure - cast iron with door) 1P up to 4P Arrow handle Chambers Padlockable handle Technical information According to IEC 60947-3 Rated thermal current Rated insulation voltage Rated impulse withstand voltage AC rated operational current Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor Normal service conditions: Ambient air temperature (ºC): -5º...+40º....

 Open the catalog to page 9
Enclosed cam switches-10

CITP CTFR Arrow handle For red/yellow handle, please consult ENCLOSED CHANGEOVER I-O-II ENCLOSED CHANGEOVER I-O-II Padlockable handle open view For red/yellow handle, please consult Technical information According to IEC 60947-3 Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor AC rated operational current Rated thermal current Rated insulation voltage Rated impulse...

 Open the catalog to page 10
Enclosed cam switches-11

CITP CITR Arrow handle Padlockable handle open view For red/yellow handle, please consult For red/yellow handle, please consult Padlockable handle Standard for CITR - T32 | T40 4 poles only For red/yellow handle, please consult Technical information Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor Normal service conditions: Ambient air temperature (ºC): -5º...+40º....

 Open the catalog to page 11

All Telergon catalogs and technical brochures

  1. ATS

    8  Pages

  2. S5M DC

    3  Pages

  3. S6R DC

    2  Pages

  4. S6N DC

    2  Pages

  5. S6 DC

    4  Pages

  6. S5 DC

    5  Pages

  7. CIF22

    2  Pages

  8. series CTR

    7  Pages

  9. CCF CCP

    3  Pages

  10. S5F

    6  Pages

  11. CEC series

    2  Pages

  12. S6N AC

    2  Pages

  13. S5M AC

    4  Pages

  14. S6 AC

    2  Pages

  15. S5 AC

    9  Pages

  16. ZBK

    4  Pages

  17. CITA

    4  Pages

  18. CITP CTFR

    3  Pages

  19. TP T TB TF

    8  Pages

  20. Cam switches

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.