Modular Input /Output HECM

Modular Input /Output HECM

Modular Input /Output HECM

Product catalog summary
Overview: The document describes the HECM Modular Input/Output system, a flexible and reliable product designed for protection and control automation systems. It features a compact 19” 1U rack design, supporting up to 48 LED channels and customizable input/output configurations.
Specifications: The system operates under various voltage levels (24/48 and 110/220 VDC) and includes voltage-supervised outputs, an internal event memory, and standard communication features. It is designed to perform reliably under electromagnetic interference and supports both Modbus RTU and optional IEC61850 protocols.
Features: The HECM system includes an isolated RS485 port, optional IRIG-B time synchronization, and a high-quality power supply with protections against over-temperature, short circuit, overcurrent, and overvoltage. It offers programmable response and release times, ranging from 3 to 250 milliseconds.
Inputs and Outputs: Inputs are optically isolated and protected with varistors, while outputs can be either relay or solid-state types. The system supports various input and output card configurations, allowing for flexibility based on customer requirements.
Communication and Integration: The system integrates easily with SCADA systems via the RS485 port and supports optional IEC61850 protocol for enhanced communication with IEDs and SCADA systems.
Event Recording: The HECM features an internal event recorder with a 1ms resolution and a 2,000 event memory buffer, making it suitable for wide-area protection systems.
Innovative Aspects: The system combines input and output functions in a single case, reduces unnecessary maneuvers through internal fault control, and supports operational safety and economic savings by terminating protection relay contact wiring in substations.
Technical Specifications: The document provides detailed technical specifications, including supply voltage ranges, input and output card types, communication protocols, and environmental features such as operating temperature and humidity.
Application Alternatives: The HECM can be used as an I/O module for the HEEP3000 event recorder product and can be synchronized with IRIG-B format or connected to IEC61850 compatible systems.
Ordering Information: The document includes order codes for different configurations of the HECM system, specifying input and output quantities and types.
See more

Catalog excerpts

Modular Input /Output HECM-1

19”, 1U RACK TYPE COMPACT DESIGN 48 pcs Channels Led Technology Customised Input/Output Quantity & Current Rating; Flexible Structure Voltage supervised Outputs Internal Event Memory Standard Communication and Event Recording Feature Reliable Performance Under Electromagnetic Interference Working under Different Voltage Levels. (24/48AND 110/220 Vdc) Isolated RS485 Port and ModbusRTU Protocol Support IEC61850 Protocol Support (optional) Irig-B Time synchroni sation with I rig-b O ptional card High quality and long life power supply with protection for over temperature, short circuit, overcurrent/overvoltage. HECM Modular Input/Output, is a flexible, functional and reliable product used in the protection and control automation systems Our product, combining low cost with good quality, compact and unique design, is an unrivaled product with standard communication and event recording features. It has electronic card alternatives for different applications. With the help of 3pcs moduler slots inside the unit, it has flexible structure which quantities of inputs/outputs, current ratings are decided upon customer requirements. Each input is isolated. It is protected by opto-coupler, harmonic suppressors and noise filtering software. Device can be safely used under the environment containing high electromagnetic noise which is continuously met. Outputs could be relay or solidstate type. Having event recording features with 1 msec resolution and 2.000 event memory. Response and release time for the environment with electromagnetic noise are to be programmed between 3-250msec. RS485 communication port supports Modbus RTU and could be easily integrated to the SCADA systems. By installing IRIG-B Optional card, you can time synchronize it with Irig-B format. By utilising IEC61850 Protocol Management Card (PMC) option, it can be used as a I/O module which is capable to connect to the IEC61850 compatible systems . It can be used as I/O module of our HEEP3000 event recorder product . Telepro Eneif ve Elektronlk Slstemled San.TIc.Ltd^tl.

 Open the catalog to page 1
Modular Input /Output HECM-2

19” Rack type Modular Structure HECM Modular Input/Output, having 1U 19” physical structure, provides flexible, smart, functional and reliable solutions for protection and control automation. It could be easily used in the wide area protection systems, thanks to the parallel working feature on RS485 bus. Communication The integrated RS485 serial communication port with galvanic isolation protection, supports Modbus RTU protocol and get easily adapted to the SCADA systems. Via optional IEC61850 Protocol Management Card, it can connect to the IEC61850 compatible systems. Internal Event Recorder It...

 Open the catalog to page 2
Modular Input /Output HECM-4

Telepro Eneif ve Elektronlk Slstemled San.TIc.Ltd^tl.

 Open the catalog to page 4
Modular Input /Output HECM-5

TELEPRO ENERJİ VE ELEKTRONİK SİSTEMLERİ SAN.TİC. LTD.ŞTİ. Ferhatpaşa Mah. 99.Sok. No:46/5 ATAŞEHİR – İSTANBUL / TURKEY Tel : +90 216 469 73 73 pbx Fax: +90 216 469 73 74 web:www.telepro.com.tre-posta: [email protected] Telepro Enerji is reserving the right to alter the data and information mentioned here,at any time without giving notice All products under 2year warranty againts manufacturi

 Open the catalog to page 5

All Telepro Enerji ve Elektronik Sist.San. Tic. Ltd. St. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.