Limit switches XCE and XCJ ranges Easy Series Catalogue Simply easy!
Open the catalog to page 1Limit switches XCE and XCJ ranges ■■General □□General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Applications examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Contact blocks operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Utilization categories IEC 60947-5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Setting up and mounting advice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□European standards . . . . . . . . . . . . . . . . . ....
Open the catalog to page 3Limit switches XC range Electromechanical detection Limit switches are used in all automated installations and also in a wide variety of applications, due to the numerous advantages inherent to their technology. They transmit data to the logic processing system regarding: b presence/absence, b passage, b positioning, b end of travel. Simple to install switches, offering many advantages b From an electrical viewpoint: v galvanic separation of circuits, v models suitable for low power switching, combined with good electrical durability, v very good short-circuit withstand in coordination with...
Open the catalog to page 4Limit switches General (suite) XC range Contact block operation Contact blocks operation Example : 1 N/C + 1 N/O tripping resetting Linear movement (plunger) Rotary movement Snap action contacts b Linear movement (plunger) European terminology A Maximum travel B Tripping travel C Resetting travel D Differential travel P Point from which positive opening is assured A-B No specific term 1 Resetting point 2 Tripping point 0 No specific term – No specific term Terminology according to JIS C 4508 TT Total travel – – – – OT Over Travel RP Release Position OP Operation Position FP Free Position...
Open the catalog to page 5Limit switches XC range Contact ratings Direct current Contact rating designation IEC 60947-5-1 Typical application Control of resistive loads and solid state loads with isolation by opto couplers Control of solid state loads with transformer 0.65 isolation Control of small electromagnetic loads 0.3 (y 72 VA) Control of electromagnetic loads (> 72 VA) 0.3 Control of resistive loads and solid state loads with isolation by opto couplers Control of electromagnets Control of electromagnetic loads having economy resistors in circuit = time to reach 95 % of the steady state current.
Open the catalog to page 6Limit switches XC range Setting up and mounting advice Reverse mounting of the operating lever (for limit switches XCE) Mounting advice Sweep of connecting cable Recommended Mounting and fixing of limit switches
Open the catalog to page 7European standards European standards Limit switches XC range Degrees of protection provided by enclosures Degrees of protection against the penetration of solid bodies, water and personnel access to live parts The European standard EN 60529 dated October 1991, IEC publication 529 (2nd edition November 1989), defines a coding system (IP code) for indicating the degree of protection provided by electrical equipment enclosures against accidental direct contact with live parts and against the ingress of solid foreign objects or water. This standard does not apply to protection against the risk...
Open the catalog to page 8American standards American standards Limit switches XC range Degrees of protection provided by enclosures Standard UL 50 - Table 6.1 - Enclosures types, defines a coding system for indicating the protection provided by electrical equipment enclosures against the ingress of solid foreign objets and fluids. Type Indoor use primarily to provide a degree of protection against limited amounts of falling dirt. Indoor use primarily to provide a degree of protection against limited amounts of falling water and dirt. Outdoor use primarily to provide a degree of protection against rain, sleet, wind...
Open the catalog to page 9Selection considerations Limit switches Operating heads selection XC range Operating heads Plunger style Operating speed Positivity (2) (1) Risk of overtravel damage Very high Lever and roller lever plunger style 0.85 m/s Target type Rotary style Yes (with non flexible levers only) Yes (with non flexible levers only) Yes (with non flexible levers only) Multidirectional style (1) These values are indicative only. For precise information relating to a particular device, refer to the appropriate technical characteristics. (2) Only when combined with a positive opening contact. (3) CW =...
Open the catalog to page 10Selection guide Limit switches XC range Medium duty: small compactors, wood working, metal working, food processing… Light duty: injection moulding, assembly, metal working, packaging… Enclosure (body) Zinc alloy (cover: plastic) Plastic (cover: zinc alloy) Linear, rotary or multi-directional 1 C/O snap action - Form C 1 NO + 1NC snap action - Form Za Screw terminal Flexible rubber cable gland suitable for cable Ø 6…9 mm Flexible rubber cable gland suitable for cable Ø 8.5…10.5 mm Type references
Open the catalog to page 11With head for linear movement (plunger) operators 561886 XC range For medium duty applications, XCE Limit switches Presentation, general characteristics With head for rotary movement (lever) operators With head for multi-directional operators Vibration resistance Shock resistance Body and head: metal, cover: plastic Mechanical durability Cable entry Tightening torques Flexible rubber cable gland suitable for cable Ø 6…9 mm 2.4...3.0 N.m / 21.24...26.55 Ib-in Head (rotary type) Roller lever (rotary type) Contact block characteristics Rated operational characteristics Rated insulation voltage...
Open the catalog to page 12Limit switches References, characteristics, dimensions XC range For medium duty applications, XCE Type of operating head Steel roller plunger for lateral Steel roller plunger for cam movement traverse cam movement XCE102C Weigth (kg) 0.110 0.126 0.126 (1) All products are supplied in individual packaging. They are also available in a bulk pack of 10 products. To order the bulk packed versions, add the suffix TQ at the end of product reference. Example XCE110CTQ. Obviously the indivisible order quantity for this version is 10. Complementary characteristics not shown under general...
Open the catalog to page 13All Telemecanique Sensors catalogs and technical brochures
-
Photo-electric sensors OsiSense XU
186 Pages
-
Safety light curtains XUSL range
38 Pages
-
Ultrasonic sensors XX range
79 Pages
-
Limit switches XC Standard range
161 Pages
-
Limit switches XC Special range
67 Pages
-
limit switch XCMN
6 Pages
-
L1422M
2 Pages
-
limit switch XCRT
5 Pages
-
limit switch XCR
5 Pages
-
limit switch XCKL
6 Pages
-
Ultrasonic sensors OsiSense XX
36 Pages
-
Limit switches OsiSense XC Standard
146 Pages
-
New 2011 sensors catalog
24 Pages
-
Model VM18 Proximity
6 Pages
-
Osiconcept Photoelectric Sensor
2 Pages
-
PhotoVirtu™ Photoelectric Sensor
4 Pages
-
Osicap Capacitive Sensors
8 Pages
Archived catalogs
-
Osiris XUA Photoelectric Sensor
2 Pages
-
Virtu™ 30A Catalog
4 Pages
-
Virtu™ Product Brochure
8 Pages