1. Catalogs
  2. Telemecanique Sensors
  3. Limit switches XCE and XCJ ranges Easy Series
video corpo

Limit switches XCE and XCJ ranges Easy Series

Limit switches XCE and XCJ ranges Easy Series
1 / 24 PagesView full catalog

Limit switches XCE and XCJ ranges Easy Series

Product catalog summary
General Overview
Limit switches in the XCE and XCJ ranges are designed for automated installations, offering advantages such as galvanic separation, high electrical durability, and electromagnetic interference immunity. They are suitable for detecting presence, passage, positioning, and end of travel.
Applications and Operation
These switches are used in various applications, including roller plunger, end plunger, rotary style head, and multidirectional head. They feature snap action and slow break contacts, with specific terminologies for linear and rotary movements.
Contact Ratings and Standards
The switches conform to IEC 60947-5-1 standards, with utilization categories for both AC and DC currents. They offer different contact ratings based on the application, ensuring compatibility with various electrical loads.
Setting Up and Mounting
Guidelines include recommendations for reverse mounting of operating levers and proper positioning of cable glands to avoid damage. Advice on the type of cam and mounting positions is provided to ensure optimal performance.
Protection Standards
European and American standards define the degrees of protection provided by enclosures. The IP code system indicates protection against solid objects and water ingress, while UL standards specify protection against environmental factors like dust and water.
Operating Heads Selection
Selection depends on factors such as direction of operation, operating speed, and risk of overtravel damage. Different styles like plunger, lever, rotary, and multidirectional are available, each with specific characteristics.
Product Specifications
The XCE range is suitable for medium duty applications, while the XCJ range is for light to medium duty. Both conform to IEC 60947-5-1 standards, with specific body dimensions, contact blocks, and degrees of protection. The XCE range offers options for linear, rotary, and multi-directional operators, with certifications and environmental resistance details provided.
Specifications
  • Materials: Body made of metal, cover made of plastic.
  • Mechanical Durability: 10 million operations.
  • Cable Entry: Flexible rubber cable gland suitable for cable diameters of 6 to 9 mm.
  • Tightening Torques: Various components have specific torque requirements, such as the body (2.4 to 3.0 N.m), cover (0.5 to 0.6 N.m), and head (0.3 to 0.4 N.m).
Electrical Characteristics
  • Rated Operational Characteristics: AC (Ue = 240 V, Ie = 3 A, Ith = 10 A); DC (Ue = 220 V, Ie = 0.3 A).
  • Rated Insulation Voltage: Ui=300V, pollution degree 3, compliant with IEC 60947.
  • Insulation Resistance: Greater than 100 mΩ at 500 V.
  • Operating Frequency: 120 operations per minute.
  • Electrical Endurance: 800,000 operations.
Product Variants
  • Types of Operating Heads: Plunger, rotary, and multi-directional.
  • Operators: Steel end plunger, steel roller plunger, thermoplastic roller lever, and more.
  • References: Various models such as XCE110C, XCE102C, XCE103C, etc., each with specific characteristics and weights.
Installation and Mounting
  • Mounting Torque: Specific torque ranges for different components and models.
  • Cabling: Screw terminals with a torque range of 0.6 to 1.1 N.m.
  • Maximum Clamping Capacity: 0.75 to 1.5 mm² per terminal.
Environmental and Compliance
  • Standards: Conforms to IEC 60947-5-1.
  • Certifications: e, CCC.
  • Ambient Temperature: Operational range from -25 to +70 °C.
  • Vibration and Shock Resistance: Compliant with IEC 60068-2-6 and IEC 60068-2-27.
  • Protection Degree: IP 40, IK 04.
Additional Notes
The document emphasizes the importance of performing risk analysis and testing for specific applications. Schneider Electric is not liable for misuse of the information provided.
See more

Catalog excerpts

Limit switches XCE and XCJ ranges Easy Series-1

Limit switches XCE and XCJ ranges Easy Series Catalogue Simply easy!

 Open the catalog to page 1
Limit switches XCE and XCJ ranges Easy Series-3

Limit switches XCE and XCJ ranges ■■General □□General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Applications examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Contact blocks operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Utilization categories IEC 60947-5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . □□Setting up and mounting advice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □□European standards . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
Limit switches XCE and XCJ ranges Easy Series-4

Limit switches XC range Electromechanical detection Limit switches are used in all automated installations and also in a wide variety of applications, due to the numerous advantages inherent to their technology. They transmit data to the logic processing system regarding: b presence/absence, b passage, b positioning, b end of travel. Simple to install switches, offering many advantages b From an electrical viewpoint: v galvanic separation of circuits, v models suitable for low power switching, combined with good electrical durability, v very good short-circuit withstand in coordination with appropriate...

 Open the catalog to page 4
Limit switches XCE and XCJ ranges Easy Series-5

Limit switches General (suite) XC range Contact block operation Contact blocks operation Example : 1 N/C + 1 N/O tripping resetting Linear movement (plunger) Rotary movement Snap action contacts b Linear movement (plunger) European terminology A Maximum travel B Tripping travel C Resetting travel D Differential travel P Point from which positive opening is assured A-B No specific term 1 Resetting point 2 Tripping point 0 No specific term – No specific term Terminology according to JIS C 4508 TT Total travel – – – – OT Over Travel RP Release Position OP Operation Position FP Free Position TTP...

 Open the catalog to page 5
Limit switches XCE and XCJ ranges Easy Series-6

Limit switches XC range Contact ratings Direct current Contact rating designation IEC 60947-5-1 Typical application Control of resistive loads and solid state loads with isolation by opto couplers Control of solid state loads with transformer 0.65 isolation Control of small electromagnetic loads 0.3 (y 72 VA) Control of electromagnetic loads (> 72 VA) 0.3 Control of resistive loads and solid state loads with isolation by opto couplers Control of electromagnets Control of electromagnetic loads having economy resistors in circuit = time to reach 95 % of the steady state current.

 Open the catalog to page 6
Limit switches XCE and XCJ ranges Easy Series-7

Limit switches XC range Setting up and mounting advice Reverse mounting of the operating lever (for limit switches XCE) Mounting advice Sweep of connecting cable Recommended Mounting and fixing of limit switches

 Open the catalog to page 7
Limit switches XCE and XCJ ranges Easy Series-8

European standards European standards Limit switches XC range Degrees of protection provided by enclosures Degrees of protection against the penetration of solid bodies, water and personnel access to live parts The European standard EN 60529 dated October 1991, IEC publication 529 (2nd edition November 1989), defines a coding system (IP code) for indicating the degree of protection provided by electrical equipment enclosures against accidental direct contact with live parts and against the ingress of solid foreign objects or water. This standard does not apply to protection against the risk of...

 Open the catalog to page 8
Limit switches XCE and XCJ ranges Easy Series-9

American standards American standards Limit switches XC range Degrees of protection provided by enclosures Standard UL 50 - Table 6.1 - Enclosures types, defines a coding system for indicating the protection provided by electrical equipment enclosures against the ingress of solid foreign objets and fluids. Type Indoor use primarily to provide a degree of protection against limited amounts of falling dirt. Indoor use primarily to provide a degree of protection against limited amounts of falling water and dirt. Outdoor use primarily to provide a degree of protection against rain, sleet, wind blown...

 Open the catalog to page 9
Limit switches XCE and XCJ ranges Easy Series-10

Selection considerations Limit switches Operating heads selection XC range Operating heads Plunger style Operating speed Positivity (2) (1) Risk of overtravel damage Very high Lever and roller lever plunger style 0.85 m/s Target type Rotary style Yes (with non flexible levers only) Yes (with non flexible levers only) Yes (with non flexible levers only) Multidirectional style (1) These values are indicative only. For precise information relating to a particular device, refer to the appropriate technical characteristics. (2) Only when combined with a positive opening contact. (3) CW = clockwise,...

 Open the catalog to page 10
Limit switches XCE and XCJ ranges Easy Series-11

Selection guide Limit switches XC range Medium duty: small compactors, wood working, metal working, food processing… Light duty: injection moulding, assembly, metal working, packaging… Enclosure (body) Zinc alloy (cover: plastic) Plastic (cover: zinc alloy) Linear, rotary or multi-directional 1 C/O snap action - Form C 1 NO + 1NC snap action - Form Za Screw terminal Flexible rubber cable gland suitable for cable Ø 6…9 mm Flexible rubber cable gland suitable for cable Ø 8.5…10.5 mm Type references

 Open the catalog to page 11
Limit switches XCE and XCJ ranges Easy Series-12

With head for linear movement (plunger) operators 561886 XC range For medium duty applications, XCE Limit switches Presentation, general characteristics With head for rotary movement (lever) operators With head for multi-directional operators Vibration resistance Shock resistance Body and head: metal, cover: plastic Mechanical durability Cable entry Tightening torques Flexible rubber cable gland suitable for cable Ø 6…9 mm 2.4...3.0 N.m / 21.24...26.55 Ib-in Head (rotary type) Roller lever (rotary type) Contact block characteristics Rated operational characteristics Rated insulation voltage Insulation...

 Open the catalog to page 12
Limit switches XCE and XCJ ranges Easy Series-13

Limit switches References, characteristics, dimensions XC range For medium duty applications, XCE Type of operating head Steel roller plunger for lateral Steel roller plunger for cam movement traverse cam movement XCE102C Weigth (kg) 0.110 0.126 0.126 (1) All products are supplied in individual packaging. They are also available in a bulk pack of 10 products. To order the bulk packed versions, add the suffix TQ at the end of product reference. Example XCE110CTQ. Obviously the indivisible order quantity for this version is 10. Complementary characteristics not shown under general characteristics...

 Open the catalog to page 13

All Telemecanique Sensors catalogs and technical brochures

  1. L1422M

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.