1. Catalogs
  2. Telemecanique Sensors
  3. Limit switches XC Standard range
video corpo

Limit switches XC Standard range

Limit switches XC Standard range
1 / 161 PagesView full catalog

Limit switches XC Standard range

Product catalog summary
Overview: The document is a comprehensive catalogue for the XC Standard range of limit switches, detailing various designs, applications, and specifications. It includes sections on miniature, compact, and classic formats, as well as special ranges for severe applications.
Key Sections:
  • Selection Guide: This section provides an overview of the different types of limit switches available, categorized by design and application. It includes information on enclosure materials, modularity, certifications, body dimensions, head types, contact blocks, degree of protection, and operating temperatures.
  • Miniature Design: Covers the XCMD and XCMV series, highlighting features like pre-cabled options, integral or remote connectors, and separate components. These are designed for compact spaces and mobile equipment.
  • Compact Design: Discusses the XCKP, XCKD, and XCKT series, focusing on plastic and metal enclosures with various cable entry options. It also includes models with reset features.
  • Classic Format: Details the XCKM and XCKL series, emphasizing metal enclosures with multiple cable entries and variable composition options.
  • EN 50041 Format: Describes the XCKS and XCKJ series, which are designed for industrial applications with high protection standards and adaptable sub-assemblies.
  • Special Range: Focuses on applications requiring high precision and low operating force, including very severe material handling and hoisting applications.
Specifications: Each section provides detailed specifications, including body dimensions, head types, contact block configurations, protection ratings, and operating temperature ranges. The document also includes conformity and certification details for each product line.
Conclusion: The catalogue serves as a detailed reference for selecting the appropriate limit switch based on specific application needs, offering a wide range of options in terms of design, material, and functionality.
Specifications:
The document outlines the specifications for various safety and limit switches, including temperature ranges, connection types, and case materials. The ambient operating temperature for most switches is between -25°C and +70°C, with some models having extended ranges. Connection options include screw terminals and pre-cabled versions, with various cable gland entries.
Procedures:
The switches are designed for operator protection by stopping machines when safety conditions are breached, such as opening a gate or displacing a lever. They are suitable for machines with quick rundown times and light industrial applications.
Standards and Certifications:
The switches conform to standards such as EN/IEC 60947-5-1, EN/ISO 13849-1, and UL 508. They are certified by UL, CSA, CCC, and EAC, ensuring compliance with international safety and quality standards.
Design and Features:
The switches come in various formats, including miniature, compact, and industrial designs. Features include different types of levers and spindles, adjustable heads, and various contact block configurations. The degree of protection ranges from IP 66 to IP 68, depending on the model.
Applications:
These switches are used in light and heavy industrial machines, particularly those with quick rundown times. They are designed to protect operators by stopping machines when safety conditions are not met.
Recommendations:
The document recommends selecting switches based on specific application needs, considering factors like machine type, environmental conditions, and required safety standards. It also highlights the importance of proper installation and maintenance to ensure optimal performance.
Key Data from Tables and Diagrams:
The document includes detailed tables listing dimensions, fixing centers, and contact block configurations for each switch type. It also provides information on the resistance to forcible withdrawal and the degree of protection offered by each model.
Specifications:
The document outlines the specifications for switches conforming to various standards such as IEC 61140 and UL 508. The degree of protection for switches with 4-pin M12 connectors is IP 66, IP 67, and IP 69 according to EN/IEC 60529, and IK 04 according to EN 62262. Switches with 4-pin Deutsch DT04-4P or AMP Superseal 1.5 connectors have the same IP ratings but an IK 06 rating. Pre-cabled switches are rated IP 66 and IP 67.
Materials:
The body and heads of the switches are made of Zamak, connectors are thermoplastic, and cables are PvR.
Performance Characteristics:
The repeat accuracy is 0.1 mm on tripping points with 1 million operating cycles for heads with end plungers. The rated operational characteristics for switches with 4-pin M12 connectors are AC-14; Ue = 24 V, Ie = 3 A, Ith = 4 A, and DC-13; Ue = 24 V, Ie = 1 A, conforming to IEC 60947-5-1. Pre-cabled switches or those with Deutsch DT04-4P or AMP Superseal 1.5 connectors have similar ratings but with Ith = 6 A.
Electrical Characteristics:
The rated insulation voltage is Ui = 36 V with a degree of pollution 3, conforming to IEC 60947-5-1 and UL 508. The rated impulse withstand voltage is Uimp = 0.8 kV. Positive operation is ensured with NC contacts having positive opening operation conforming to IEC 60947-5-1.
Durability and Operation:
The switches have an electrical durability conforming to IEC 60947-5-1 Appendix C, with utilization categories AC-14 and DC-13. The maximum operating rate is 3600 cycles/hour with a load factor of 0.5. The minimum actuation speed for snap-action contacts is 0.01 m/minute and for slow-break contacts is 6 m/minute.
Mechanical Characteristics:
The switches have a mechanical durability of 10 million operating cycles. The minimum force or torque for tripping is 8.5 N, and for positive opening, it is 42.5 N.
References and Models:
The document provides references for various models of limit switches, including those with different types of heads and operators, such as metal end plungers and steel roller plungers. It also includes details on modular units for mobile equipment with different connector types.
Graphical Data:
The document includes graphical data showing the relationship between current in amperes and the number of operating cycles for different switch configurations and connectors.
Specifications:
1. Clamping Capacity: XE3NP and XE3SP have a clamping capacity ranging from a minimum of 1 x 0.34 mm2 to a maximum of 1 x 1 mm2 or 2 x 0.75 mm2.
2. Actuation Speed: Minimum actuation speed for XE2SP21p1 and XE3SP is 0.01 m/minute, while for XE2NP21p1 and XE3NP it is 6 m/minute.
3. Electrical Durability: Conforms to IEC 60947-5-1 Appendix C with utilization categories AC-15 and DC-13. Maximum operating rate is 3600 cycles/hour with a load factor of 0.5.
Electrical Characteristics:
1. AC Supply: 50/60 Hz inductive circuit.
2. DC Supply: Power broken in watts for 5 million operating cycles varies with voltage (24V, 48V, 120V) and type (XE2SPp151, XE3SPpppp, XE3NPpppp).
General Characteristics:
1. Limit Switches: XC Standard range, industrial format EN 50041, metal conforming to CENELEC EN 50041, XCKJ.
2. Types of Operators: Includes metal end plunger, steel roller plunger, thermoplastic roller lever, and others.
3. Mechanical Durability: Ranges from 25 to 30 million operating cycles depending on actuation type.
Connections and Dimensions:
1. Cable Entry: Options include ISO M20 x 1.5, Pg 13.5, and 1/2" NPT conduit.
2. Connector Types: M12 and 7/8"-16UN connectors with various pre-wired female connectors available.
3. Dimensions: Detailed dimensions provided for various switch models and configurations.
See more

Catalog excerpts

Limit switches XC Standard range-1

Limit switches XC Standard range Catalogue Simply easy!

 Open the catalog to page 1
Limit switches XC Standard range-2

Limit switches XC Standard range Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 b Variable composition: Simplicity through innovation. . . . . . . . . . . . . . . . page 16 b General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18 v Complete units, pre-cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 70 v Complete units with 1 cable entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 104 v Complete units with 2 cable...

 Open the catalog to page 2
Limit switches XC Standard range-3

Selection guide Limit switches XC Standard range Miniature format Compact format, CENELEC EN 50047 Compact format, CENELEC EN 50047 Compact format, with reset Metal, pre-cabled Miniature format for mobile equipments Metal, pre-cabled Plastic, 1 cable entry Plastic, 2 cable entries Plastic, 1 cable entry Metal, 1 cable entry Plastic, 2 cable entries Metal, 1 cable entry Plastic, double insulated Plastic, double insulated Plastic, double insulated Head, body and connection modularity Head, body and connection modularity Head, body and cable entry modularity Head and body modularity Head, body and...

 Open the catalog to page 3
Limit switches XC Standard range-4

Selection guide Limit switches XC Standard range “Classic” format Metal, 3 cable entries Industrial EN 50041 format Metal, 1 cable entry Miniature format Plastic, 1 cable entry Plastic, pre-cabled Plastic, 1 cable entry Metal, 1 cable entry or connector Compact format, with reset knob Plastic, 2 cable entries Plastic, 1 cable entry Plastic, 2 cable entries Head, body and operator modularity Linear movement (plunger) Rotary movement (lever) Rotary movement, multidirectional Plastic, double insulated Plastic, double insulated – e, UL, CSA, CCC, EAC Linear movement (plunger) Rotary movement (lever)...

 Open the catalog to page 4
Limit switches XC Standard range-5

Limit switches Selection guide Very severe material handling applications For hoisting and material handling applications (XCR); for conveyor belt shift monitoring (XCRT) For hoisting and material handling applications Subminiature format and microswitch. Applications requiring high precision and a low operating force Metal, 1 cable entry Very severe applications Metal, 3 cable entries Metal or polyester, 1 cable entry Metal or plastic, 3 cable entries Plastic, pre-cabled Head and body modularity Linear movement (plunger) or rotary movement (lever) Linear movement (plunger) Rotary movement (lever)...

 Open the catalog to page 5
Limit switches XC Standard range-6

Safety limit switches Selection guide Switch type XCS safety limit switches XCS lever or spindle-operated safety switches Protection of operators by stopping the machine when the gate is opened. All machines with quick rundown time. Protection of operators by stopping the machine when the Protection of operators by stopping the machine when the guard hinge rotates through 5°. operating lever (attached to hinged machine guard) is All light industrial machines fitted with hinged access doors. displaced by 5°. All light industrial machines fitted with hinged or rotary protective covers with small...

 Open the catalog to page 6
Limit switches XC Standard range-7

Selection guide (continued) Safety limit switches XCS range Switch type XCS key-operated safety switches XCS key-operated safety switches Protection of operators by stopping the machine when the actuating key (attached to machine guard) is withdrawn from the head of the switch. All light industrial machines with quick rundown time (1). All heavy industrial machines with quick rundown time (1) Miniature format Compact format Industrial format with or without locking With 1 or 2 cable entries With 1 cable entry, without locking Without locking of actuating key. With 1 cable entry and manual locking/unlocking...

 Open the catalog to page 7
Limit switches XC Standard range-8

Selection guide (continued) Safety limit switches XCS range Switch type XCS key-operated safety switches, locking and unlocking by solenoid XCS key-operated safety switches, locking and unlocking by solenoid (continued) Protection of operators by stopping the machine when the actuating key (attached to machine guard) is withdrawn from the head of the switch. All industrial machines with long rundown time (1) Protection of operators by stopping the machine when the actuating key (attached to machine guard) is withdrawn from the head of the switch. All industrial machines with long rundown time...

 Open the catalog to page 8
Limit switches XC Standard range-9

Selection guide (continued) Safety limit switches Switch type XCSR contactless RFID safety switches XCS safety coded magnetic safety switches for detection without contact Highly tamper-proof protection of operators by stopping the machine when the gate is opened (transfer lines, assembly lines, automated equipment, machine tools, etc.). All light industrial machines fitted with access gates with imprecise guidance and/or subjected to frequent washing, shocks and vibrations. This Safety sensor is suitable for machine with low inertia. Miniature rectangular format Compact rectangular format Cylindrical...

 Open the catalog to page 9
Limit switches XC Standard range-10

Limit switches XC range Variable composition: simplicity through innovation Variable composition principle b The Miniature design XCMD and XCMV, and Compact design XCKD, XCKP and XCKT ranges benefit from the variable composition concept. b A worldwide detection first for improving productivity. A complete offer for resolving the most commonly encountered detection problems: v product selection simplified, v product availability simplified, v installation and setting-up simplified, v maintenance simplified. Heads b A single metal operating head type for the Miniature design XCMD and XCMV, and...

 Open the catalog to page 10
Limit switches XC Standard range-11

General (continued) Limit switches XC range Variable composition: simplicity through innovation Principle (continued) Cable entries b The cable entries for Compact design XCKD and XCKP switches enable: v simple cabling due to unrestricted access to contacts, v simple adaptation to the various worldwide markets: - 6 models are available: v ISO M16 x 1.5 v Pg 11 v ISO M20 x 1.5 v Pg 13.5 v 1/2" NPT v PF 1/2 (G 1/2) Each model is available in metal or plastic, respectively suited to Compact design XCKD and XCKP. Connection components b The miniature XCMD range allows interchanging of these pre-cabled...

 Open the catalog to page 11

All Telemecanique Sensors catalogs and technical brochures

  1. L1422M

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.