Limit switches XC Special range
67Pages

{{requestButtons}}

Catalog excerpts

Limit switches XC Special range - 1

Limit switches XC Special range Catalogue Simply easy!

Open the catalog to page 1
Limit switches XC Special range - 3

Limit switches XC Special range ■ Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ For very severe applications, XC2J □ Presentation and characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □ Complete switches, fixed boby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . □ Variable composition: fixed or plug-in body. . . . . . . . . . . . . . . . . . . . . . □ Adaptable sub-assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16 page 18 page 20 page 22 - For low...

Open the catalog to page 3
Limit switches XC Special range - 4

Selection guide Limit switches XC Standard range Miniature format Miniature format for mobile equipments Compact format, CENELEC EN 50047 Compact format, CENELEC EN 50047 Compact format, with reset Metal, pre-cabled Metal, pre-cabled Plastic, 1 cable entry Plastic, 2 cable entries Metal, 1 cable entry Plastic, 1 cable entry Plastic, double insulated Plastic, double insulated Plastic, double insulated Head, body and connection modularity Head, body and connection modularity Head, body and cable entry modularity Head and body modularity Head, body and connection modularity Linear movement...

Open the catalog to page 4
Limit switches XC Special range - 5

Selection guide Limit switches XC Standard range “Classic” format Metal, 3 cable entries Plastic, 1 cable entry Metal, 1 cable entry or connector Plastic, pre-cabled Plastic, 1 cable entry Plastic, double insulated Metal, 1 cable entry Miniature format Plastic, double insulated Head, body and operator modularity Linear movement (plunger) Rotary movement (lever) Rotary movement, multidirectional Compact format, with reset knob Plastic, 2 cable entries Plastic, 1 cable entry Plastic, 2 cable entries Linear movement (plunger) Rotary movement (lever) Rotary movement, multidirectional Contact...

Open the catalog to page 5
Limit switches XC Special range - 6

Limit switches Selection guide Very severe applications Very severe material handling applications For hoisting and material handling applications (XCR); for conveyor belt shift monitoring (XCRT) For hoisting and material handling applications Subminiature format and microswitch. Applications requiring high precision and a low operating force Metal, 1 cable entry Metal, 3 cable entries Metal or polyester, 1 cable entry Metal or plastic, 3 cable entries Plastic, pre-cabled Head and body modularity Linear movement (plunger) or rotary movement (lever) Linear movement (plunger) Rotary movement...

Open the catalog to page 6
Limit switches XC Special range - 7

Safety limit switches Selection guide Switch type XCS safety limit switches XCS lever or spindle-operated safety switches Protection of operators by stopping the machine when the gate is opened. All machines with quick rundown time. Protection of operators by stopping the machine when the Protection of operators by stopping the machine when the guard hinge rotates through 5°. operating lever (attached to hinged machine guard) is All light industrial machines fitted with hinged access doors. displaced by 5°. All light industrial machines fitted with hinged or rotary protective covers with...

Open the catalog to page 7
Limit switches XC Special range - 8

Selection guide (continued) Safety limit switches XCS range Switch type XCS key-operated safety switches XCS key-operated safety switches Protection of operators by stopping the machine when the actuating key (attached to machine guard) is withdrawn from the head of the switch. All light industrial machines with quick rundown time (1). All heavy industrial machines with quick rundown time (1) Miniature format Compact format Industrial format with or without locking With 1 or 2 cable entries With 1 cable entry, without locking Without locking of actuating key. With 1 cable entry and manual...

Open the catalog to page 8
Limit switches XC Special range - 9

Selection guide (continued) Safety limit switches XCS range Switch type XCS key-operated safety switches, locking and unlocking by solenoid XCS key-operated safety switches, locking and unlocking by solenoid (continued) Protection of operators by stopping the machine when the actuating key (attached to machine guard) is withdrawn from the head of the switch. All industrial machines with long rundown time (1) Protection of operators by stopping the machine when the actuating key (attached to machine guard) is withdrawn from the head of the switch. All industrial machines with long rundown...

Open the catalog to page 9
Limit switches XC Special range - 10

Selection guide (continued) Safety limit switches Switch type XCSR contactless RFID safety switches XCS safety coded magnetic safety switches for detection without contact Highly tamper-proof protection of operators by stopping the machine when the gate is opened (transfer lines, assembly lines, automated equipment, machine tools, etc.). All light industrial machines fitted with access gates with imprecise guidance and/or subjected to frequent washing, shocks and vibrations. This Safety sensor is suitable for machine with low inertia. Miniature rectangular format Compact rectangular format...

Open the catalog to page 10
Limit switches XC Special range - 11

Limit switches XC Special range For very severe applications, XC2J v With head for linear movement (plunger) with 1 cable entry v With head for rotary movement (lever)

Open the catalog to page 11
Limit switches XC Special range - 12

Limit switches General characteristics For very severe applications, XC2J Environment characteristics Product certifications Protective treatment Ambient air temperature Products Machine assemblies Standard version Special version Standard version For operation For storage Vibration resistance Shock resistance Electric shock protection Degree of protection Repeat accuracy Cable entry Contact block characteristics Rated operational characteristics Rated insulation voltage Resistance across terminals Short-circuit protection Connection Screw clamp terminals Minimum actuation speed Electrical...

Open the catalog to page 12
Limit switches XC Special range - 13

Limit switches References, characteristics For very severe applications, XC2J Complete switches, fixed body, 1 cable entry incorporating cable gland Single-pole CO snap action XCKZ01 Steel roller plunger Metal side plunger Thermoplastic roller lever (1) Variable length thermoplastic roller lever (1) Actuation from left AND right ZC2JC1 + ZC2JC1 + ZC2JE01 + ZC2JE01 + ZC2JY11 ZC2JY31 Actuation from left OR right ZC2JC1 + ZC2JC1 + ZC2JE05 + ZC2JE05 + ZC2JY11 ZC2JY31 Weight (kg) Contact operation Switch actuation Type of actuation Maximum actuation speed Mechanical durability (in millions of...

Open the catalog to page 13

All Telemecanique Sensors catalogs and technical brochures

  1. L1422M

    2 Pages