Catalog excerpts
Electronic sensors for pressure control OsiSense XM Catalogue Simply easy!
Open the catalog to page 1Electronic pressure sensors OsiSense XM Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2 to 9 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 10 to 13 XMLR pressure sensors with 4-digit display bb bb bb bb bb
Open the catalog to page 3Selection guide Electronic pressure sensors OsiSense XM Control circuits Control circuits Type of sensor and features Devices without display Pressure transmitters Analogue output, 4…20 mA or 0...10 V Devices without display Pressure transmitters Analogue output, 4…20 mA or 0...10 V. Fluids or products controlled Fluid connection Rated supply voltage Voltage limits Current consumption Electrical connection M12, EN 175301-803-A (ex-DIN 43650A) or Packard Metri-Pack 150 connector (3) M12 connector (1) or integrated quick connection (5) Materials in contact with fluid Ceramic Al2O3 , stainless...
Open the catalog to page 4Selection guide Electronic pressure sensors OsiSense XM Control circuits Control circuits Type of sensor and features Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Fluids or products controlled Fresh water (0…+ 125 °C) Air, hydraulic oils (- 15…+ 125 °C) Fresh water (0…+ 135°C) Air, hydraulic oils, refrigeration fluids (- 30…+ 135°C) Fluid connection G 1/4 A DIN 3852-E male, 1/4”-18NPT male, SAE 7/16-20...
Open the catalog to page 5Selection guide Electronic pressure sensors Control circuits Control circuits Type of sensor and features Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Fluids or products controlled Hydraulic oils, air, fresh water, gas (- 40…+ 125 °C ) Hydraulic oils, air, fresh water, gas (- 40…+ 125 °C ) Fluid connection Rated supply voltage Voltage limits Current consumption Electrical connection Materials in contact...
Open the catalog to page 6Selection guide Electronic pressure sensors OsiSense XM Control circuits Control circuits Type reference and features Switches with 4-digit display Pressure transmitters with 4-digit display Pressure and vacuum switches with 4-digit display - With an analogue output, 4…20 mA and a switching output, PNP or NPN type - With two PNP or NPN switching outputs - With one analogue output, 4…20 mA or 0...10 V and one input for diagnosis - With one analogue output, 4…20 mA or 0…10 V and one switching output, PNP or NPN type - With two switching outputs, PNP or NPN type - With one analogue output,...
Open the catalog to page 7Electronic pressure sensors OsiSense XM Electronic pressure sensors The function of electronic pressure sensors is the control and measurement of pressure or vacuum levels in hydraulic or pneumatic systems. Being electronic, the sensors have no mechanical moving parts. Pressure transmitters Pressure transmitters convert the pressure into an electrical signal which is proportional to the applied pressure. Their high precision makes them suitable for all industrial applications requiring pressure/vacuum display, control or regulation. Being very robust, they are equally suitable for...
Open the catalog to page 8General (continued) Electronic pressure sensors OsiSense XM Operating principle (continued) Pressure and vacuum switches (continued) Switching output: hysteresis mode Hysteresis mode is generally used for pumping and/or emptying applications. Pressure SP rP Time Output 1 NO 0 1 NC 0 Time Time SP: High switching point rP: Low switching point NP: Nominal pressure Switching output: Window mode Window mode is generally used for pressure regulation applications. Pressure FH FL Time Time FH: High switching point FL: Low switching point NP: Nominal pressure Switching output: time delay mode Time...
Open the catalog to page 9Electronic pressure sensors OsiSense XM Nominal pressure NP or size The nominal pressure is the maximum pressure or vacuum which can be measured by the sensor. Maximum permissible accidental pressure This is the maximum pressure, excluding pressure surges, to which the pressure sensor can occasionally be subjected without being damaged. Destruction pressure The pressure value which if exceeded is likely to cause serious damage to the sensor i.e. leaking, bursting, component failure, etc. High switching point (SP) This is the upper pressure setting selected on the pressure or vacuum switch...
Open the catalog to page 10Selection criteria for a pressure sensor Electronic pressure sensors OsiSense XM Main criteria for selecting an electronic pressure sensor The fluid or gas to be controlled Our products, including the materials used, are compatible with the majority of fluids or gases encountered in industrial applications. However some particularly corrosive fluids (sea water, for example) can affect product operation sooner or later. The fluid temperature can also be an aggravating factor. The materials in contact with the fluid are described in the technical data sheets which can be found on our website,...
Open the catalog to page 11Electronic pressure sensors Presentation, functions XMLK pressure transmitters Plastic body, stainless steel 303 fluid entry. With analogue output Presentation XMLK pressure transmitters are characterised by their ceramic pressure measuring cell. The deformation caused by the pressure is transmitted to the resistors of a Wheatstone bridge screen-printed on the ceramic. The change in resistance is then processed by the integrated electronics, giving an analogue output signal. The stainless steel AISI 303 fluid entry and the ceramic cell combined with a nitrile gasket make these transmitters...
Open the catalog to page 12Electronic pressure sensors OsiSense XM XMLK pressure transmitters Plastic body, stainless steel 303 fluid entry. With analogue output. Sizes in bar 0 to 6 bar (0 to 87 psi) Maximum permissible accidental pressure: 12 bar, destruction pressure: 18 bar Analogue output type Electrical connection G 1/4 A (male) fluid connection 4…20 mA Maximum permissible accidental pressure: 20 bar, destruction pressure: 30 bar Analogue output type Electrical connection G 1/4 A (male) fluid connection 4…20 mA Maximum permissible accidental pressure: 32 bar, destruction pressure: 48 bar Analogue output type...
Open the catalog to page 13All Telemecanique Sensors catalogs and technical brochures
-
Photo-electric sensors OsiSense XU
186 Pages
-
Safety light curtains XUSL range
38 Pages
-
Ultrasonic sensors XX range
79 Pages
-
Limit switches XC Standard range
161 Pages
-
Limit switches XC Special range
67 Pages
-
limit switch XCMN
6 Pages
-
L1422M
2 Pages
-
limit switch XCRT
5 Pages
-
limit switch XCR
5 Pages
-
limit switch XCKL
6 Pages
-
Ultrasonic sensors OsiSense XX
36 Pages
-
Limit switches OsiSense XC Standard
146 Pages
-
New 2011 sensors catalog
24 Pages
-
Model VM18 Proximity
6 Pages
-
Osiconcept Photoelectric Sensor
2 Pages
-
PhotoVirtu™ Photoelectric Sensor
4 Pages
-
Osicap Capacitive Sensors
8 Pages
Archived catalogs
-
Osiris XUA Photoelectric Sensor
2 Pages
-
Virtu™ 30A Catalog
4 Pages
-
Virtu™ Product Brochure
8 Pages