1. Catalogs
  2. Telemecanique Sensors
  3. Electronic sensors for pressure control OsiSense XM
video corpo

Electronic sensors for pressure control OsiSense XM

Electronic sensors for pressure control OsiSense XM
1 / 54 PagesView full catalog

Electronic sensors for pressure control OsiSense XM

Product catalog summary
Overview: This document is a catalogue for OsiSense XM electronic pressure sensors, detailing various models, specifications, functions, and applications. It includes a selection guide and technical information for different types of pressure transmitters and sensors.
1. Electronic Pressure Sensors - OsiSense XM: This section provides a selection guide for electronic pressure sensors, outlining their general features and applications.
2. XMLK Pressure Transmitters for Water: These transmitters are designed for water applications, with detailed specifications and references for sizes in bar and psi, along with accessories.
3. XMLG Pressure Transmitters: Suitable for various applications, these transmitters are characterized by a ceramic pressure measuring cell and stainless steel body, with detailed references for sizes and accessories.
4. XMLP Pressure Transmitters: These transmitters are compact and suitable for pressures less than 9 bar or 100 psi, with various output types and connection options.
5. XMEP Pressure Transmitters for Mobile Equipment: Designed for mobile equipment, these transmitters are compact, rugged, and certified for harsh environments.
6. ZMLP Switches with 4-Digit Display: These switches feature a display and are detailed with references and accessories.
7. XMLR Pressure Sensors with 4-Digit Display: These sensors offer configurable functions and are suitable for various industrial applications.
Technical Specifications: The document includes detailed technical specifications for each type of sensor, including fluid connections, voltage limits, current consumption, electrical connections, output types, materials, precision, service life, dimensions, standards, certifications, temperature ranges, protection degrees, vibration and shock resistance, and type references.
Applications and Installation: The sensors are suitable for various applications, including control circuits and installations without displays, designed to handle different fluids and environmental conditions.
Materials and Construction: The sensors are constructed with durable materials like ceramic AL2O3, stainless steel 316L, and FPM fluorocarbon, ensuring compatibility with various fluids.
Functions: The sensors convert pressure into electrical signals for display, control, or regulation, with high repeat accuracy and fast response times.
Operating Principles: Pressure transmitters provide an analogue output proportional to the applied pressure, while pressure and vacuum switches offer digital outputs based on adjustable switching points.
Selection Criteria: Consider the fluid or gas type, maximum pressure, fluid entry format, and electrical output configuration when selecting a pressure sensor.
Accessories: Includes M12 connectors, pre-wired connectors, and quick connection parts, with options for straight and elbowed versions.
General Characteristics: All models offer high precision and are suitable for demanding industrial applications, with varying protection ratings.
Legal and Copyright Information: TMSS France disclaims liability for damages arising from the use of the catalogue's information, which is protected under copyright laws.
Contact Information: TMSS France is headquartered at Tour Eqho, 2 avenue Gambetta, 92 400 Courbevoie, France.
Important Notices: Users are advised to confirm the information provided due to potential changes in standards, specifications, and design.
See more

Catalog excerpts

Electronic sensors for pressure control OsiSense XM-1

Electronic sensors for pressure control OsiSense XM Catalogue Simply easy!

 Open the catalog to page 1
Electronic sensors for pressure control OsiSense XM-3

Electronic pressure sensors OsiSense XM Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2 to 9 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 10 to 13 XMLR pressure sensors with 4-digit display bb bb bb bb bb

 Open the catalog to page 3
Electronic sensors for pressure control OsiSense XM-4

Selection guide Electronic pressure sensors OsiSense XM Control circuits Control circuits Type of sensor and features Devices without display Pressure transmitters Analogue output, 4…20 mA or 0...10 V Devices without display Pressure transmitters Analogue output, 4…20 mA or 0...10 V. Fluids or products controlled Fluid connection Rated supply voltage Voltage limits Current consumption Electrical connection M12, EN 175301-803-A (ex-DIN 43650A) or Packard Metri-Pack 150 connector (3) M12 connector (1) or integrated quick connection (5) Materials in contact with fluid Ceramic Al2O3 , stainless steel...

 Open the catalog to page 4
Electronic sensors for pressure control OsiSense XM-5

Selection guide Electronic pressure sensors OsiSense XM Control circuits Control circuits Type of sensor and features Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Fluids or products controlled Fresh water (0…+ 125 °C) Air, hydraulic oils (- 15…+ 125 °C) Fresh water (0…+ 135°C) Air, hydraulic oils, refrigeration fluids (- 30…+ 135°C) Fluid connection G 1/4 A DIN 3852-E male, 1/4”-18NPT male, SAE 7/16-20 UNF-2B...

 Open the catalog to page 5
Electronic sensors for pressure control OsiSense XM-6

Selection guide Electronic pressure sensors Control circuits Control circuits Type of sensor and features Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Devices without display Pressure transmitters Analogue output, 4…20 mA, 0...10 V or ratiometric output, 0.5...4.5 V Fluids or products controlled Hydraulic oils, air, fresh water, gas (- 40…+ 125 °C ) Hydraulic oils, air, fresh water, gas (- 40…+ 125 °C ) Fluid connection Rated supply voltage Voltage limits Current consumption Electrical connection Materials in contact with...

 Open the catalog to page 6
Electronic sensors for pressure control OsiSense XM-7

Selection guide Electronic pressure sensors OsiSense XM Control circuits Control circuits Type reference and features Switches with 4-digit display Pressure transmitters with 4-digit display Pressure and vacuum switches with 4-digit display - With an analogue output, 4…20 mA and a switching output, PNP or NPN type - With two PNP or NPN switching outputs - With one analogue output, 4…20 mA or 0...10 V and one input for diagnosis - With one analogue output, 4…20 mA or 0…10 V and one switching output, PNP or NPN type - With two switching outputs, PNP or NPN type - With one analogue output, 4…20...

 Open the catalog to page 7
Electronic sensors for pressure control OsiSense XM-8

Electronic pressure sensors OsiSense XM Electronic pressure sensors The function of electronic pressure sensors is the control and measurement of pressure or vacuum levels in hydraulic or pneumatic systems. Being electronic, the sensors have no mechanical moving parts. Pressure transmitters Pressure transmitters convert the pressure into an electrical signal which is proportional to the applied pressure. Their high precision makes them suitable for all industrial applications requiring pressure/vacuum display, control or regulation. Being very robust, they are equally suitable for applications...

 Open the catalog to page 8
Electronic sensors for pressure control OsiSense XM-9

General (continued) Electronic pressure sensors OsiSense XM Operating principle (continued) Pressure and vacuum switches (continued) Switching output: hysteresis mode Hysteresis mode is generally used for pumping and/or emptying applications. Pressure SP rP Time Output 1 NO 0 1 NC 0 Time Time SP: High switching point rP: Low switching point NP: Nominal pressure Switching output: Window mode Window mode is generally used for pressure regulation applications. Pressure FH FL Time Time FH: High switching point FL: Low switching point NP: Nominal pressure Switching output: time delay mode Time delay...

 Open the catalog to page 9
Electronic sensors for pressure control OsiSense XM-10

Electronic pressure sensors OsiSense XM Nominal pressure NP or size The nominal pressure is the maximum pressure or vacuum which can be measured by the sensor. Maximum permissible accidental pressure This is the maximum pressure, excluding pressure surges, to which the pressure sensor can occasionally be subjected without being damaged. Destruction pressure The pressure value which if exceeded is likely to cause serious damage to the sensor i.e. leaking, bursting, component failure, etc. High switching point (SP) This is the upper pressure setting selected on the pressure or vacuum switch at...

 Open the catalog to page 10
Electronic sensors for pressure control OsiSense XM-11

Selection criteria for a pressure sensor Electronic pressure sensors OsiSense XM Main criteria for selecting an electronic pressure sensor The fluid or gas to be controlled Our products, including the materials used, are compatible with the majority of fluids or gases encountered in industrial applications. However some particularly corrosive fluids (sea water, for example) can affect product operation sooner or later. The fluid temperature can also be an aggravating factor. The materials in contact with the fluid are described in the technical data sheets which can be found on our website, www.tesensors.com....

 Open the catalog to page 11
Electronic sensors for pressure control OsiSense XM-12

Electronic pressure sensors Presentation, functions XMLK pressure transmitters Plastic body, stainless steel 303 fluid entry. With analogue output Presentation XMLK pressure transmitters are characterised by their ceramic pressure measuring cell. The deformation caused by the pressure is transmitted to the resistors of a Wheatstone bridge screen-printed on the ceramic. The change in resistance is then processed by the integrated electronics, giving an analogue output signal. The stainless steel AISI 303 fluid entry and the ceramic cell combined with a nitrile gasket make these transmitters particularly...

 Open the catalog to page 12

All Telemecanique Sensors catalogs and technical brochures

  1. L1422M

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.