1. Catalogs
  2. Teledyne Tekmar
  3. Versa Headspace Analyzer

Versa Headspace Analyzer

Versa Headspace Analyzer

Versa Headspace Analyzer

Product catalog summary
Overview
The Versa Automated Headspace Vial Sampler by Teledyne Tekmar is designed for analyzing volatile organic compounds (VOCs) in various matrices. It simplifies sample preparation and minimizes contamination, making it a cost-effective solution for headspace analysis.

Applications and Industries
  • Residual solvents in pharmaceuticals (USP Method <467>)
  • Dissolved Gas Analysis (Method RSK-175)
  • Contaminants in packaging materials
  • VOCs in water and soil
  • High-level sample screening (EPA Method 5021)
  • China Environmental Method GB-5749
  • Flavor and fragrance profiling
  • Forensics and toxicology

Features and Benefits
  • Compact size (12” wide) with significant value
  • 20-position autosampler with a single position platen oven
  • Sample heating up to 200°C
  • Inert sample pathway to reduce adsorption and carryover
  • Automatic Leak Check and Benchmark test for troubleshooting
  • Method Optimization Mode (M.O.M.) for efficient method development
  • Versa TekLink™ 2G software for standard or 21 CFR compliance

Specifications
  • Autosampler capacity: 20-position
  • Platen heater: Ambient to 200°C
  • Vial size: 22mL
  • Sample loop: Standard 1mL Silco® coated loop
  • Sample pathway: Siltek® tubing, temperature controlled
  • Software: Versa TekLink™ 2G, Windows® XP or higher
  • GC interface: Compatible with most GC instruments
  • Pressure control: Consistent volume via pressure transducer
  • Valving: Motor-actuated 6-port valve
  • Voltage requirements: 100/115 VAC or 220/240 VAC
  • Gas requirements: Ultra-high purity Helium or Nitrogen
  • Dimensions: 21in x 12in x 21in
  • Weight: 40lbs
  • Environmental conditions: Operating temperature 10° to 30°C
  • Certifications: CE, CETL, CSA, ETL

Service and Support
Teledyne Tekmar offers installation, training, and validation packages (IQ, OQ) to ensure compliance and optimal instrument performance. Their customer service is supported by an ISO 9001 Certified Quality System.
See more

Catalog excerpts

Versa Headspace Analyzer-1

Catalogo TS-32 portada.psd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:11.00pt "Arial", sans-serif; } .font2 { font:16.00pt "Arial", sans-serif; } .font3 { font:31.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Trebuchet MS", sans-serif; } Versa Automated Headspace Vial Sampler . TELEDYNE TEKMAR A Teledyne Technologies Company

 Open the catalog to page 1
Versa Headspace Analyzer-2

Catalogo TS-32 portada.psd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:16.00pt "Arial", sans-serif; } .font5 { font:28.00pt "Arial", sans-serif; } .font6 { font:5.00pt "Times New Roman", serif; } Small Size. Big Value. Automated Static Headspace System Static headspace is one of the most popular techniques due to its versatility for analyzing volatile organic compounds (VOCs) in a complex...

 Open the catalog to page 2
Versa Headspace Analyzer-3

Catalogo TS-32 portada.psd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:16.00pt "Arial", sans-serif; } .font2 { font:28.00pt "Arial", sans-serif; } .font3 { font:64.00pt "Arial", sans-serif; } .font4 { font:160.00pt "Arial", sans-serif; } Versa Features and Benefits Small on size yet big on value (only 12" wide) Օ 20-position autosampler/single position platen oven for static sampling analysis of 22mL vials Sample heating to 200oC throughout pathway Օ Built-in pressure control to ensure consistent volume for all samples...

 Open the catalog to page 3
Versa Headspace Analyzer-4

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:16.00pt "Arial", sans-serif; } .font2 { font:27.00pt "Lucida Sans Unicode", sans-serif; } Versa TekLink 2G Fully Optimized User Interface Versa comes with easy-to-use and proven TekLink 2G software that operates from Windows XP or higher and includes 21 CFR compliance tools. All instrument parameters, method scheduling and editing can be programmed. Benchmark - Versa TekLinkٙ 2G is capable of performing useful diagnostics such as a Leak Check and Benchmark test. The Benchmark...

 Open the catalog to page 4
Versa Headspace Analyzer-5

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:20.00pt "Arial", sans-serif; } .font3 { font:27.00pt "Lucida Sans Unicode", sans-serif; } VersaSpcifications Autosampler Capacity 20-Position Platen Heater Single position; ambient to 200°C via rsistance heater settable in 1°C incr驩ments Vial Size 22mL vials Sample Loop Ships with a standard 1mL Silco® coated loop. Other optional loop sizes include 100, 250, 500pL as well as 2, 3, and 5mL Sample Mixing System allows variable power...

 Open the catalog to page 5
Versa Headspace Analyzer-6

Catalogo TS-32 portada.psd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:11.00pt "Trebuchet MS", sans-serif; } Teledyne Tekmar can help with your instrument installation. Our team of trained service professionals can provide extended on site training for successful operation and instrument maintenance. For those needing documentation on analytical...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.