Overview: The document provides technical specifications for the LS10 series DC Solid-State Relay designed for printed circuit boards, capable of handling up to 10A and 60 Vdc.
Part Numbers: The series includes models LS60DC10C-21 and LS60DC10F-21, both rated at 10A, 36 Vdc.
Electrical Specifications:
  • Input (Control) Specifications: The LS60DC10C operates within a control range of 3-10 Vdc and an input current range of 7-32 mA, while the LS60DC10F operates within 7-30 Vdc and 6-29 mA. Both models have a must turn-off voltage of 1 Vdc.
  • Output (Load) Specifications: Operating range is 7-36 Vdc with a peak voltage of 60 Vpeak. The output current range is 0.0001-10 A, with a clamping voltage by Transil at 40V@1mA and [email protected]. Maximum surge current rating is 100 A.
Features/Benefits: The relay features a slim compact design, heatsinking capabilities, integrated voltage protection, and high surge handling capability.
Mechanical Specifications: The relay has a weight of 0.53 oz (15g) with dimensions provided in inches and millimeters. Tolerances are ±0.007 (±0.2).
Environmental Specifications: Operating temperature ranges from -40 to +80°C, and storage temperature ranges from -40 to +120°C. Input-output and input-output-case isolation are rated at 2500 Vrms.
Thermal Characteristics: A graph illustrates the relationship between ambient temperature and load current, indicating performance across a range of temperatures.
Notes: The document includes notes on peak voltage, switch type, control range, and features such as self turn-on voltage protection.
See more

Catalog excerpts

LS10 Series-1

TELEDYNE RELAYS ATeledyne Technologies Company Series LS10 Output to 10A, 60 Vdc DC Solid-State Relay for Printed Circuit Boards FEATURES/BENEFITS • Slim compact design • Heatsinking capabilities • Integrated voltage protection • High surge handling capability • MOSFET output Part Number Description LS60DC10C-21 10A, 36 Vdc Part Number Explanation Peak Voltage1 Output Current - Amps Feature4 NOTES 1) Peak Voltage (peak): 60 = 60 Vdc 2) Switch Type: DC = Random turn-on (DC) 3) Control Range: C = 3-10 Vdc; F = 7-30 Vdc 4) Feature: -21 = self turn-on voltage protection (transil) ELECTRICAL SPECIFICATIONS (+20°C ambient temperature unless otherwise specified) INPUT (CONTROL) SPECIFICATIONS Min Max Units Tolerances: ±0.007 (±0.2) Weight: 0.53 oz. (15g) Dimensions in inches (millimeters) Figure 1 BLOCK DIAGRAM Input Current Range LS60DC10C 7 32 mA Must Turn-Off Voltage All relays 1 Vdc Input Resistance (Typical) LS60DC10C 270 Ohms © *On inductive loads = Suppressed diode © 2006 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com

 Open the catalog to page 1
LS10 Series-2

Output to 10A, 60 Vdc DC Solid-State Relay for Printed Circuit Boards ELECTRICAL SPECIFICATIONS (+20°C ambient temperature unless otherwise specified) OUTPUT (LOAD) SPECIFICATIONS Operating Range BLOCK DIAGRAM Peak Voltage Output Current Range Clamping Voltage by Transil 40V@1mA V [email protected] V Maximum Energy for Transil 1ms Maximum Surge Current Rating (10ms) 100 Maximum Power for Transil Off-State Leakage Current Turn-On Time Turn-Off Time Operating Frequency Range On-State Voltage Drop ** For switching frequencies greater than 1Hz, you may need to reduce the current. For more information,...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.