Overview: The document provides technical specifications for the Series E3P solid-state relays by Teledyne Relays, designed for three-phase output up to 75A and 600 Vac with both DC and AC control options.
Specifications:
  • Input (Control): Control voltage ranges from 8.5-30 Vdc for E3P R/D models and 90-240 Vac/Vdc for E3P A models. Input current varies from 4-55 mA depending on the model.
  • Output (Load): Operating voltage ranges from 24-600 Vrms, with a peak voltage of 1200 Vpeak. Load current ranges from 0.005 to 75 Arms, with a maximum surge current rating of up to 1000 A for 75A output models.
  • Environmental: Operating temperature ranges from -55 to 100 ºC for E3P48D50 and -40 to 100 ºC for other models. Input-output isolation is rated at 4000 Vrms.
Features/Benefits:
  • Three-phase output with AC or DC control.
  • Internal output protection and control LED on all models.
  • Designed for various load types with excellent thermal performance and high surge immunity.
Applications: Suitable for heating control, motor control, uninterruptible power supplies, light dimmers, and industrial process control.
Approvals: All models are UL recognized under file number E128555.
Thermal Characteristics: Power dissipation and thermal resistance are detailed for different load currents, emphasizing the need for heat sinks under certain conditions.
Figures and Diagrams: The document includes mechanical dimensions, block diagrams, and graphs illustrating control characteristics, power dissipation, and surge current capabilities.
See more

Catalog excerpts

E3P Series-1

TELEDYNE RELAYS Everywhereyoulook' Series E3P Three-Phase Output to 75A 600 Vac DC and AC Control Solid-State Relay Part Number Description Part Number Explanation 1) Line Voltage (nominal): 48 = 480 Vac 2) Switch Type: R = Random turn-on; D = Zero-cross turn-on; A = AC control, Zero-cross turn-on MECHANICAL SPECIFICATION FEATURES/BENEFITS •Three-phase output •AC or DC control •Internal output protection •Control LED on all models •Designed for all types of loads •Excellent thermal performance •Tight zero-cross window for low EMI •High immunity to surges DESCRIPTION The Series E3P three-phase relays are designed for all types of loads. The design incorporates a thyristor output. Control status LED is a standard on all models. Output protection is provided internally on certain models. The Series E3P utilizes optical isolation to protect the control from load transients. High-current models are excellent for motor control. APPLICATIONS •Heating control •Motor control •Uninterruptible power supplies •Light dimmers •Three-phase industrial and process control •On/Off controls of AC equipment APPROVALS All models are UL recognized. UL File Number: E128555. © 2016 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com

 Open the catalog to page 1
E3P Series-2

TELEDYNE RELAYS Everywhereyoulook' Series E3P Three-Phase Output to 75A 600 Vac DC and AC Control Solid-State Relay INPUT (CONTROL) SPECIFICATION Input Type Min Max Units Control Range E3P R/D 8.5 30 Vdc BLOCK DIAGRAM Input Current Range E3P R/D 10 45 mA Must Turn-Off Voltage All Relays 4 Vdc Input Resistance (Typical) E3P R/D 620 Ohms Reverse Voltage Protection E3P R/D 30 V SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2016 TELEDYNE RELAYS

 Open the catalog to page 2
E3P Series-3

TELEDYNE RELAYS Everywhereyoulook' Series E3P Three-Phase Output to 75A 600 Vac DC and AC Control Solid-State Relay OUTPUT (LOAD) SPECIFICATION Min Max Units Operating Range E3P48XX-16 24 520 Vrms Peak Voltage All Relays 1200 Vpeak Load Current Range 12A output current .005 12 Arms OUTPUT (LOAD) SPECIFICATION (Continued) Min Max Units Maximum di/dt (Non-Repetitive) All relays 50 A/ps Operating Frequency Range E3P48D50 10 680 Hz Inductive Load Current E3P with -16 option 50A output 12 Arms Maximum Surge Current Rating (Non-Repetitive) 12A output 120 A...

 Open the catalog to page 3
E3P Series-4

Series E3P Three-Phase Output to 75A 600 Vac DC and AC Control Solid-State Relay THERMAL CHARACTERISTICS SURGE CURRENT Repetitive with initial Tj = 70°C Without heat sink Load Current (Arms) Repetitive with initial Tj = 70°C Without heat sink Load Current (Arms) Repetitive with initial Tj = 70°C 60 50% duty cycle (R type only) Without heat sink 0 Load Current (Arms) Full on-state Repetitive with initial Tj = 70°C 0 0.01 Without heat sink Load Current (Arms) NOTES: 1. Electrical specifications at 25°C unless otherwise specified. 2. For 800Hz applications, contact factory. 3. For additional/custom...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.