Overview: The Ultraflow 150 is an advanced ultrasonic gas flow and temperature monitor designed for use in stacks and ducts. It provides high accuracy and flexibility with a maintenance-free, non-contacting technique.
Key Features:
  • Non-Contacting Technique: Transducers are housed in Teflon and protected by purge air, minimizing maintenance needs.
  • Velocity Measurement: Independent of temperature, pressure, and density, with a resolution of 50 nanoseconds.
  • Accuracy and Drift: Offers a line average response with a long-term drift of ±1% and a resolution better than ±0.3 ft/sec.
  • Dynamic Calibration: Complies with 40CFR75 requirements, allowing for daily or on-command calibration checks.
  • Digital Signal Processing: Utilizes FPGA for fast and accurate responses, suitable for hazardous waste applications.
  • Remote Panel: User-friendly interface with multiple I/O options and a large LCD display.
  • Installation: Simplified with robust components, adaptable to various pipe sizes.
Technical Specifications:
  • Flow Measurement Range: 0-200 ft/sec (0-61 m/sec).
  • Temperature Range: -40° to 650°F (-40° to +343°C).
  • Pressure Range: -30 to 20 inches of H2O.
  • Particulate Tolerance: Up to 3000 mg/m³.
  • Power Requirements: 85-245VAC, 47-63Hz, Single Phase.
Additional Features:
  • Purge Air System: Maintains transducer cleanliness and dryness, with single or dual blower options.
  • Ethernet Interface: Offers multilevel password-protected access to TCP/IP networks.
  • Training and Support: Includes an operation manual and optional training sessions at Teledyne facilities or customer sites.
Applications: Suitable for both small and large stacks, the Ultraflow 150 is designed to handle challenging conditions such as high flow rates and cyclonic flow, ensuring reliable and accurate measurements.
See more

Catalog excerpts

ULTRAFLOW 150, ULTRASONIC GAS FLOW AND TEMPERATURE MONITOR-1

TELEDYNE INSTRUMENTS Monitor Labs A Teledyne Technologies Company ULTRASONIC GAS FLOW AND TEMPERATURE MONITOR

 Open the catalog to page 1
ULTRAFLOW 150, ULTRASONIC GAS FLOW AND TEMPERATURE MONITOR-2

Ultraflow 150’s state-of-the-art signal processing and innovative modularity offers customers incomparable performance, accuracy, flexibility and a maintenance-free solution amongst all flow technologies. Innovative, non-contacting technique greatly reduces maintenance The Ultraflow 150 is a patented advance in continuous flow measurement systems for small and large stacks and ducts. Transducers are non-intrusively mounted in Teflon housing and are protected from flue gas and particulate with continuous purge air. This noncontacting method mitigates maintenance and ensures long term operation...

 Open the catalog to page 2
ULTRAFLOW 150, ULTRASONIC GAS FLOW AND TEMPERATURE MONITOR-3

Transducer Interface Enclosure (TIE) Electrical signals corresponding to acoustic transmit and receive signals are conveyed via cables between the transducers and the TIE. The TIE houses preamp /driver boards that amplify receive signals and transmit pulses. A signal processing board containing an FPGA controls timing, data collection, filtering, boxcar integration and other functions. A microprocessor board evaluates the box car data and determines time of flight, flow velocity, volume, speed of sound, temperature and signal to noise ratio. All these data values may be viewed via the Enhanced...

 Open the catalog to page 3
ULTRAFLOW 150, ULTRASONIC GAS FLOW AND TEMPERATURE MONITOR-4

Specifications Flow Measurement: Training An Operation and Maintenance Manual is provided with the ULTRAFLOW 150. In addition, periodic hands-on training classes are conducted at the Teledyne Monitor Labs facility. Training classes may also be scheduled at the customer’s site. Range: Resolution: Long-Term Repeatability: Relative Accuracy: (VS. EPA Test Method 2) Response Time: Initial Calibration: Factory calibration based on duct geometry plus flow data. Available for site specific calibration against pitot tube traverses. +/- 1% reading over full range of rated ambient temperature and line...

 Open the catalog to page 4
ULTRAFLOW 150, ULTRASONIC GAS FLOW AND TEMPERATURE MONITOR-5

The Ultraflow 150 A state-of-the-art advance in flow and temperature measurement of stacks and ducts Ultra-low drift operation Full system integrity calibration checks Low mounting angle rejects pitch flow effects Non-intrusive, non-contacting technique Flow measurement independent of flue gas composition, pressure and temperature Measurement technique rejects cyclonic flow EPA’s stringent 7.5% RATA requirement and flow-to-load ratio checks established the need for accurate and repeatable flow measurement. Teledyne Monitor Lab’s Ultraflow achieves this consistent accuracy. 40 CFR Part 75 and...

 Open the catalog to page 5
ULTRAFLOW 150, ULTRASONIC GAS FLOW AND TEMPERATURE MONITOR-6

Teledyne Monitor Labs, Inc. Leading the way in Emissions Monitoring Throughout its history, Teledyne Monitor Labs has developed and patented breakthrough advances in emission monitoring technology. Teledyne Monitor Lab’s drift-free Ultraflow Volumetric Flow Monitor was the first to perform across-the-stack zero span calibration checks. Now, Teledyne Monitor Labs has advanced the technology to include quad-sets of transducers to handle unique application issues eliminating the need for additional platforms and to improve response time for process control applications. The Ultraflow’s modular design...

 Open the catalog to page 6

All Teledyne Monitor Labs catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.