Introduction
The document introduces the Prodigy ICP, a high-performance simultaneous ICP developed by Teledyne Leeman Labs, emphasizing their commitment to superior atomic spectroscopy products and support.
Key Features
  • Performance and Versatility: Offers industry-leading performance with various sample introduction options, high throughput automation, and reduced gas consumption. Capable of analyzing halogens with speed and accuracy.
  • Ease of Use: User-friendly system requiring minimal training, with on-screen maintenance prompts.
  • Dependability: Built for long-term use with lifetimes exceeding 10 years, ensuring consistent operation.
  • Advanced Detection: Features a Large Format Programmable Array Detector for simultaneous data acquisition and full wavelength coverage.
Technical Specifications
  • Stability and Precision: Drift-free analysis with image-stabilized ICP and thermally-stabilized optics for high stability and precision.
  • Resolution and Detection Limits: Low stray light levels, superior resolution, and lower detection limits in complex matrices.
  • Wavelength Coverage: Continuous coverage from 165 to 1100 nm, extendable to 134 nm with halogen option.
  • Operator-Selectable Resolution: Users can choose resolution settings to enhance sensitivity and reduce spectral interference.
Software and Automation
  • Intuitive Software: Offers intuitive navigation, network readiness, and compliance tools for method development and data analysis.
  • Automated Instrument Control: Computer-controlled parameters with automated start-up and shutdown features.
  • Element Selection and Analysis: Easy element selection and method creation with warnings for spectral interferences.
Sample Management
Streamlined process for managing sample sequences, supporting import from LIMS or manual entry, with automatic insertion of standards and quality control checks.
Calibration
Allows entry of any combination of elements and concentrations for standards, with detailed calibration display and multiple algorithms available.
Results
Provides icons for standards, quality control checks, and samples, with data viewable numerically or as spectra. Tools for identifying uncalibrated elements and eliminating matrices.
Reporting
Versatile report generator with options for specifying sample types and exporting reports to LIMS.
Maintenance
Automated maintenance monitor with detailed support and diagnostics for peak performance.
After Sales Support
Includes telephone assistance, remote diagnostics, and on-site service within 48 hours, with various service agreements available.
Standards
Provides Plasma-Pure standards and reagents traceable to NIST standards for accuracy and stability.
Company Commitment
Emphasizes commitment to quality and customer support, with investment in research and development and a reputation for reliability.
See more

Catalog excerpts

Prodigy Brochure-1

Prodigy High Dispersion ICP

 Open the catalog to page 1
Prodigy Brochure-2

High Performance Simultaneous ICP with State-of-the-Art Array Detection At Teledyne Leeman Labs atomic spectroscopy is our business, our only business. We are deeply committed to providing you with technically superior products and the highly responsive support you need to meet or exceed your elemental analysis needs. Reduced capital equipment purchases and shrinking budgets mandate that any analytical instrument you acquire not only deliver the performance and operational robustness needed to meet your requirements today, but next month, next year or years from now as well. The Prodigy was designed...

 Open the catalog to page 2
Prodigy Brochure-3

Expect More If you are looking for an ICP that is ready for every analytical challenge you face, you need to look no further than Prodigy. It is designed to exceed your expectations and deliver unprecedented performance. ■ Speed & Sample Throughput Get accurate results fast with Prodigy’s simultaneous data acquisition and full wavelength coverage. Better Results With Prodigy you will measure lower concentrations more accurately, be able to choose the best analytical wavelength, dilute samples less often and pass QC requirements easily. Ease-of-Use Spend less time training new operators and tweaking...

 Open the catalog to page 3
Prodigy Brochure-4

Process samples in as little as 35 seconds each Finish First Analyze your Samples Faster than you ever dreamed possible: simultaneously collect peak, background, internal standard and IEC data for all desired elements in a single exposure. The ICP is a laboratory workhorse; often called upon to run hundreds of samples per day. In order to meet increasing productivity demands, it is essential to have an ICP that gets your analyses started with minimal effort, that reliably meets your laboratory control requirements and processes countless samples with exceptional speed and accuracy. Prodigy is...

 Open the catalog to page 4
Prodigy Brochure-5

Axial, Radial or Dual View Prodigy is available in axial, radial or dual view configurations; each equipped with a computer controlled source mirror for automated optimization. In dual view mode, the mirror automatically selects the view and optimizes plasma viewing position in each mode. It ensures you are running at peak performance all of the time. Low Stray Light for Exceptional Detection Limits in Real World Matrices Prodigy’s Long Focal Length Spectrometer results in significantly lower stray light levels than that of other ICPs. This translates into lower detection limits and superior...

 Open the catalog to page 5
Prodigy Brochure-6

Large Format Programmable Array Detector Prodigy’s large format programmable array detector (L-PAD) is designed specifically for atomic spectroscopy, incorporating all the characteristics critical to an ICP’s performance. Its large size and in-pixel processing make it possible for Prodigy to provide high resolution and broad wavelength coverage as well as fast, wide dynamic range analysis. With Prodigy, the operator will benefit from fewer spectral interferences and unmatched versatility in adapting to new applications. Photoactive Area The L-PAD, shown on the right, has 4x the active area of...

 Open the catalog to page 6
Prodigy Brochure-7

In Pixel Processing Charge coupled devices (CCDs) move charge from the pixels of interest (analyte peak or background) to a remote amplifier to measure signal. As this transfer occurs, all pixels must be processed or the signal is lost. This approach is slow and limits the dynamic range and signal to noise ratios that can be obtained. L-PAD transfers the charge between two storage locations within each pixel. It then can measure the signal at the pixel of interest without affecting any other pixel. L-PAD reads each pixel non-destructively, so small signals are processed at their optimum signal...

 Open the catalog to page 7
Prodigy Brochure-8

l^f QC DualView - Tefedyne Leeman Method View Run Tools Help Instrument Control - Element Selection Internal Standards j-- Quality Control Checks ; -Analytical Parameters Prodigy Software Prodigy's software provides intuitive navigation between applications, network readiness, access security and regulatory compliance tools. It is based on familiar navigator conventions commonly employed on the Web with a simple tree structure and application tabs for associated functions. Frequent operations can be accessed with icons available at the top of each display. Three Application tabs appear at the...

 Open the catalog to page 8
Prodigy Brochure-9

Some key features of Prodigy’s software are shown on the following pages. See how easy it is to set instrument parameters, add elements, set up automated sequences, analyze samples and report results. Element Selection Create methods with as many wavelengths as you desire. Simply click the element symbol on the Periodic Table and a list of wavelengths appears. Prodigy then provides you the choice of selecting the default wavelength or any other wavelength you prefer. At the same time Prodigy will warn you of possible spectral interferences on the line you select. Automated Analyses Creating automated...

 Open the catalog to page 9
Prodigy Brochure-10

Numeric Data Spectral Thumbnails Icons appear for standards, quality control checks, samples, full spectrum, automated sequences and stat (high priority) samples. View the data for each reading either numerically, as spectral thumbnails or detailed spectra for each wavelength, or as raw data with calculations applied for validation. When a full spectrum is acquired built-in tools enable you to identify elements/wavelengths that had not been calibrated, eliminate matrices, find additional corroborating wavelengths and much more. Full Echellogram Raw Data with Calculations When it comes time to...

 Open the catalog to page 10
Prodigy Brochure-11

Scheduled Maintenance O^ir filter replacement O Argon tank replacement O Camera chiller water change Q Camera chiller water check level Q Camera purge gas dehydrate! @ Nebulizer cleaning Pump tubinc © FIF Oscillator Recirculate! filtei O FIF Oscillator Recirculate! flush Q RF Oscillator Reciiculatoi watei Q Sample intro o-rings Next Service ICP is an analytical workhorse. Keeping it running at peak performance is essential to laboratory success.To help achieve this, Prodigy comes with an automated maintenance monitor. When maintenance is required, the Maintenance button turns red. Clicking that...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.