Introduction
Teledyne Leeman Labs offers the Hydra Series of mercury analyzers, known for their high sensitivity and compliance with EPA and international standards. These analyzers use techniques such as cold vapor atomic absorption (CVAA) and fluorescence (CVAF) to analyze liquids, solids, and gases.
Hydra Series Overview
  • Hydra IIAA: Utilizes CVAA for liquid samples with a detection limit of 1 ppt and features a high-capacity autosampler and over-range protection.
  • Hydra IIAF: Employs CVAF for sub-ppt detection, with a dynamic range extending to high ppb levels. The Gold variant includes a gold amalgamation system for lower detection limits.
  • Hydra-C: Allows direct analysis of solid or liquid samples without preparation, using thermal decomposition and atomic absorption.
  • Hydra-CAppendix K: Designed for measuring mercury emissions from industrial sources, compliant with specific EPA methods.
Key Features and Benefits
  • High Sensitivity: Advanced fluorescence detection systems in the Hydra IIAF models achieve detection limits as low as 0.05 ppt with preconcentration.
  • Over-Range Protection: Systems prevent contamination from high mercury samples, ensuring reliable operation.
  • High Throughput: The autosampler processes up to 270 samples, enhancing productivity.
  • Compliance and Standards: Instruments comply with EPA methods 245.7 and 1631E, and European standards.
Unique Features of Hydra IIAF Gold
  • Preconcentration Capability: The gold amalgamation system allows for lower detection limits and compliance with stringent EPA standards.
  • On-Site Certification Assistance: Optional support for meeting EPA method 1631E requirements.
Conclusion
The Hydra Series provides comprehensive solutions for mercury analysis, offering high sensitivity, regulatory compliance, and features that enhance productivity and data quality.
System Overview
The Hydra II system is optimized for EPA and EN methodologies, with capabilities in data storage, retrieval, reporting, and LIMS integration.
Instrument Control
Fully automated with graphical display of conditions, allowing control over system functions like lamp, pump, and autosampler.
QC Automation
Offers flexibility for automated analysis, defining calibration and quality control locations, and supports unique actions for each check.
Sample Sequencing
Sample names can be manually entered or downloaded from LIMS, with automatic insertion of calibration standards and QC checks.
Real-Time Signals
Provides direct comparison of integrated measurements, saved with sample data for review.
Reporting Flexibility
Reports can be generated and exported for use by LIMS or third-party software.
Control Chart
Graphical display of QC results with calculated acceptance limits for tracking precision and stability.
21 CFR Compliance Tools
Includes tools for 21 CFR 11 documentation requirements, such as audit trails and permanent records.
Maintenance and Support
Software suggests maintenance procedures and offers remote diagnostics. Various service agreements are available.
Reagents
Validated standards and reagents are provided for sample digestion and analysis, emphasizing reagent purity.
Specifications
Lists the principle of operation, required gases, power requirements, dimensions, weight, and operating conditions for the Hydra II system.
See more

Catalog excerpts

Hydra II AF and Hydra II AF Gold-1

Hydra IIAF and Hydra IIAF Gold The World’s Most Sensitive Mercury Analyzers Inorganic Standards

 Open the catalog to page 1
Hydra II AF and Hydra II AF Gold-2

Don’t Settle for just any Mercury Analyzer... ...Go with the Experts in Mercury Analysis ...Go with Teledyne Leeman Labs Teledyne Leeman Labs offers both the technical expertise and products needed for your most demanding mercury analysis challenges When the concentration of mercury needs to be accurately measured, laboratories all over the world turn to Teledyne Leeman Labs for high performance solutions to their mercury analysis challenges. Since introducing the first fully automated mercury analyzer in the late 1980’s, Teledyne Leeman Labs has focused on advancing the analytical methodologies...

 Open the catalog to page 2
Hydra II AF and Hydra II AF Gold-3

The Hydra Series at a Glance • Primarily for liquid samples • Determine Hg from low ppt to ppm levels • Primarily for liquid samples • Determine Hg from sub ppt to high ppb levels Hydra II AF Gold • Primarily for liquid samples • Determine Hg from 0.05 ppt to high ppb levels Hydra-C • Primarily for solid samples • Determine Hg in various matrices without sample preparation Detection Limit Dynamic Range 0.005 to 1000 ng (or up to 20,000 ng with the high range option) Scientific Method Chemical reduction followed by cold vapor atomic absorption Gas/Liquid Separation Leeman Labs High Performance...

 Open the catalog to page 3
Hydra II AF and Hydra II AF Gold-4

Hydra IIAF Gold Fully compliant with EPA Methods 245.7 and 1631E as well as European Standards EN-13506 and EN-12338

 Open the catalog to page 4
Hydra II AF and Hydra II AF Gold-5

Introducing the World’s Most Sensitive Mercury Analyzers – the Hydra IIAF and Hydra IIAF Gold In an effort to routinely achieve sub ppt levels of detection for mercury, analysts around the globe are turning to cold vapor atomic fluorescence (CVAF) instrumentation from Teledyne Leeman Labs. We offer two CVAF – based instruments to meet your needs; the Hydra II AF and the Hydra II AF Gold . While the Hydra II AF and Hydra II AF Gold share a similar architecture (see Figures 1a and 1b) they are designed to address different methodologies and provide significantly different detection capabilities....

 Open the catalog to page 5
Hydra II AF and Hydra II AF Gold-6

Benefits found in both the Hydra IIAF and Hydra IIAF Gold ACHIEVE LOWER DETECTION AND REPORTING LIMITS RUN MORE SAMPLES WITH LESS LABOR Advanced Fluorescence Detection System. Both configurations of the Hydra II AF incorporate a proprietary wide angle fluorescence detector for the ultimate in sensitivity. This detector is designed with tangential gas flow for rapid equilibration and washout of Hg vapor; and further, it delivers a detection limit of 0.1 ppt without preconcentration and well under 0.05 ppt with preconcentration. High Capacity Autosampler. In an effort to free your analyst for other...

 Open the catalog to page 6
Hydra II AF and Hydra II AF Gold-7

Unique to the Hydra IIAF Gold REPORT MERCURY AT CONCENTRATIONS FROM SUB PPT TO HIGH PPB LEVELS With preconcentration the Hydra II AF Gold achieves a Method Detection Limit1 (MDL) of less than 0.05 ppt and easily satisfies the accuracy requirement of the sub–ppt Report Limit1 standard in method 1631E; which is 0.5 ppt +/- 23%. MEET LOW DETECTION LEVELS WITH LESS SAMPLE The figure above shows the stability of an on-going precision and recovery standard (OPR) collected over an 8-hour working day. Method 1631E requires a 5 ppt OPR standard be analyzed with every batch of samples (20 maximum). The...

 Open the catalog to page 7
Hydra II AF and Hydra II AF Gold-8

Intuitive Software Maximizing the The operating software for the Hydra II Series is a no-nonsense package designed to maximize the productivity of Hydra II and your laboratory. It automates all aspects of instrument operation as well as all autosampler functions. This is critical, especially for over-range protection. It also handles data storage, retrieval and reporting while providing powerful tools to assist with sample ID downloads and data uploads to LIMS systems. Hydra II is optimized for current EPA and EN methodologies, but with the versatility needed to handle any application. All calculations...

 Open the catalog to page 8
Hydra II AF and Hydra II AF Gold-9

SAMPLE SEQUENCING WITH "ON-THE-FLY" PROGRAMMING For automated analysis the sample names are entered into the sample table. Sample names can be entered manually or by download from your LIMS System. Calibration standards and quality control checks established in the QC Automation section of the software are inserted automatically. While a sequence is running, new samples can be added. REAL-TIME SIGNALS During analysis, real-time signal displays provide direct comparison of integrated measurements. These signals are saved with the sample data and are always available for review. Here is the signal...

 Open the catalog to page 9
Hydra II AF and Hydra II AF Gold-10

Hydra IIAF Software Scheduled Maintenance iV/aste Dian Tubing Reductant Bottle □earn Optical Cell Clew E (demaf Opltts Replace Diyo Muted T utsng Ass&mbly uVUetlt lestSevice I Neat Service |~ SCHEDULED MAINTENANCE AND ON-LINE AUDIO/VISUAL HELP To keep the Hydra II running at optimal performance, the software automatically displays suggested maintenance along with detailed help describing proper procedures. CONTROL CHART Control Charting provides a graphical display of QC results along with calculated acceptance limits. This feature simplifies tracking the precision and stability of repeated quality...

 Open the catalog to page 10
Hydra II AF and Hydra II AF Gold-11

Become a Teledyne Leeman Labs Customer... ...you’ll find yourself in good company As you know, beyond the initial purchase price lies the true cost of ownership, and that’s where the Hydra Series shines. Why? Because Teledyne Leeman Labs has built these instruments to last. Performance Guarantee Like you, we expect our instruments to perform reliably, that’s why we offer a unique comprehensive performance guarantee. Teledyne Leeman Labs warrants the Hydra Series of Mercury Analyzers to: 1. Meet or exceed all functional and QC requirements of the EPA methods for which they were designed. 2. Provide...

 Open the catalog to page 11
Hydra II AF and Hydra II AF Gold-12

Atomic Fluorescence TELEDYNE LEEMAN LABS A Teledyne Technologies Company 6 Wentworth Drive • Hudson, NH 03051 U.S.A.

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.