1. Catalogs
  2. Teledyne LeCroy Europe
  3. WaveRunner 6 Zi Oscilloscopes

WaveRunner 6 Zi Oscilloscopes

WaveRunner 6 Zi Oscilloscopes
1 / 28 PagesView full catalog

WaveRunner 6 Zi Oscilloscopes

Product catalog summary
Overview
The WaveRunner® 6 Zi Series is a high-performance oscilloscope range offering bandwidths from 400 MHz to 4 GHz with 8-bit and 12-bit resolution. It is designed for superior validation, debugging, and analysis, featuring advanced triggering, a user-friendly interface, and fast performance.
Key Features
  • Comprehensive serial data analysis with over 17 trigger, decode, and compliance solutions.
  • Excellent signal fidelity with a 12-bit ADC providing up to 55 dB Signal-to-Noise Ratio (SNR).
  • Unmatched performance with deep memory, 40 GS/s sample rate, and low noise.
  • WavePilot control area for easy navigation and documentation.
  • Rotating and tilting 12.1" widescreen display for optimal viewing.
Specifications
  • 12-bit ADC resolution with 256 Mpts/Ch deep memory.
  • ±0.5% F.S. DC gain accuracy and 55 dB SNR.
  • 1 mV vertical sensitivity at full bandwidth and up to ±400 V offset capability.
  • Multiple noise filtering options (20 MHz, 100 MHz, 200 MHz, 350 MHz).
Advanced Analysis Tools
  • ProtoSync™ for simultaneous oscilloscope and data link layer views.
  • TriggerScan™ for capturing rare events quickly.
  • Customizable tools using C/C++, MATLAB, Excel, JScript, and Visual Basic.
  • History mode for reviewing past waveforms and anomalies.
Serial Data Solutions
  • Supports a wide range of protocols including I2C, SPI, UART, CAN, LIN, FlexRay, and more.
  • True hardware protocol trigger for signals up to 3 Gb/s.
  • Eye diagrams and jitter analysis tools for physical layer analysis.
Conclusion
The WaveRunner 6 Zi Series is a versatile and powerful tool for engineers needing comprehensive debugging and analysis capabilities in a compact and user-friendly package.
Specifications Overview
The document provides detailed specifications for the WaveRunner series oscilloscopes, including models hRo 64 Zi, hRo 66 Zi, 604 Zi, 606 Zi, 610 Zi, 620 Zi, 625 Zi, and 640 Zi. Key specifications include:
Vertical System
DC vertical offset accuracy is specified as ±(1.5% of offset setting +1% of full scale + 1 mV).
Horizontal System
Timebases range from 20 ps/div to 1.6 ks/div with standard memory, extendable with memory options. Clock accuracy is ≤ 1.5 ppm.
Triggering System
Various modes and sources are available, including edge, window, and TV-composite video triggers. SMART triggers with exclusion technology are also supported.
Acquisition System
Single-shot sample rates vary by model, with up to 40 GS/s on 2 channels. Memory options allow for extensive data storage.
Acquisition Processing
Features include averaging up to 1 million sweeps, enhanced resolution from 8.5 to 15 bits, and interpolation options such as linear and Sin x/x.
Display and Interface
The oscilloscopes feature a 12.1" color touchscreen display with WXGA resolution, supporting up to 16 traces. Interfaces include Ethernet, USB, and optional GPIB.
Power and Environmental Specifications
Power requirements are 100–240 VAC with a maximum consumption of 500 W. Operating temperature ranges from +5 °C to +40 °C, with non-operating conditions extending to –20 °C to +60 °C.
Additional Features
Standard math tools and measure tools are available, allowing for complex data analysis and parameter measurement. Pass/fail testing and jitter analysis are also supported.
Key Features
  • Timing Parameters: Includes track graphs for parameters like Cycle-Cycle Jitter, Frequency, Period, Duty Cycle, and more. Histograms can handle up to 2 billion events.
  • Software Options: SDA II Serial Data Analysis offers tools for total jitter measurement, eye diagrams, and jitter decomposition models. Power Analyzer Option simplifies power switching device measurements and control loop analysis.
  • Cable De-embedding: Removes cable effects from measurements by entering S-parameters or attenuation data.
  • Serial Trigger and Decode: Options for various protocols including 8b/10b, CANbus, FlexRay, USB, and more, with capabilities for multi-lane analysis and compliance testing.
  • Spectrum Analysis: Advanced FFT capabilities with automatic setup, spectrogram display, and peak markers.
  • Disk Drive Measurements: Provides parameters and mathematical functions for disk drive analysis.
Specifications
  • Oscilloscope Models: Range from 400 MHz to 4 GHz bandwidth, with sampling rates up to 20 GS/s and memory options up to 128 Mpts/Ch.
  • Memory and Sample Rate Options: Various configurations available, including upgrades for RAM and hard drive capacity.
  • Probes: Includes passive and active differential probes with bandwidths up to 1.5 GHz.
Ordering Information
Detailed product codes and descriptions for oscilloscopes, memory options, software options, and accessories are provided for easy reference.
Product Overview
This document provides a detailed list of high impedance active probes, differential amplifiers, optical-to-electrical converters, high-voltage probes, and current probes offered by Teledyne LeCroy. Each product is specified with its unique features, frequency range, impedance, and voltage or current capacity.
High Impedance Active Probes
  • ZS1500: 1.5 GHz, 0.9 pF, 1 MΩ
  • ZS2500: 2.5 GHz, 0.9 pF, 1 MΩ
Both models are available in sets of four (QUADPAK).
WaveLink Differential Amplifiers
  • D600A-AT: 6 GHz with adjustable tip
  • D300A-AT: 3 GHz with adjustable tip
  • D500PT: 5 GHz with positioner tip
Optical-to-Electrical Converters
  • OE425: 500-870 nm range
  • OE455: 950-1630 nm range
High-Voltage Differential Probes
  • ADP300: 1,400 V, 20 MHz
  • ADP305: 1,400 V, 100 MHz
High-Voltage Probes
Various models with different voltage capacities ranging from 600 V to 20 kV, including PPE1.2KV, PPE2KV, PPE4KV, PPE5KV, PPE6KV, and PPE20KV.
Current Probes
Models include AP015, CP030, CP031, CP150, and CP500, with varying current capacities and frequency ranges.
Differential Amplifiers
DA1855A series offers 1 or 2 channel options with precision voltage sources, available with or without rackmount.
Ordering Information
For complete probe systems, additional components such as the WL-PBUS-CASE Platform/Cable Assembly may be required. Specifications and availability are subject to change.
Trademark Information
Product names and trademarks are acknowledged, including PCI Express® and MATLAB®.
See more

Catalog excerpts

WaveRunner 6 Zi Oscilloscopes-1

WaveRunner® 6 Zi Series 400 MHz– 4 GHz (8-bit and 12-bit Resolution) The Ultimate Debug Machine

 Open the catalog to page 1
WaveRunner 6 Zi Oscilloscopes-2

The Ultimate Debug Machine Superior Validation, Debug, Analysis WaveRunner® The 6 Zi defines superiority in a test instrument with a powerful feature set including a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance. Most Comprehensive Serial Data Analysis WaveRunner 6 Zi offers the most tools for serial data analysis. With over 17 trigger, decode, and compliance solutions, WaveRunner 6 Zi can address problems with unique, powerful views and automated...

 Open the catalog to page 2
WaveRunner 6 Zi Oscilloscopes-3

Unbelievable Performance The WaveRunner 6 Zi oscilloscope is the most versatile scope in the 400 MHz to 4 GHz class. The performance offered is unmatched, offering deep memory, 40 GS/s sample rate, low noise and fast operation to help get the job done quickly and accurately. The WaveRunner HRO 6Zi defines the best in class noise performance with a 12 bit ADC to provide the best resolution. The HRO 6Zi also features deep memory options up to 256 Mpts/Ch. The toolset provides every necessity for an engineer to validate a design, debug errors at board bring up, and offer powerful analysis to characterize...

 Open the catalog to page 3
WaveRunner 6 Zi Oscilloscopes-4

complete Debug solution from 400 MHz–4 GHz WaveRunner 6 Zi combines the power of a fully featured multi-purpose oscilloscope, a dedicated logic analyzer for mixed signal design, and a protocol analyzer for serial data debug. 1. Industry leading performance— 400 MHz—4 GHz, 40 GS/s, 256 Mpts of analysis memory 2. 2.1" Widescreen (16 x 9) high 1 resolution WXGA color touch screen display 3. 0º rotating and tilting display for 9 optimal viewing of signals 4. Small footprint, only 8.1" deep 5. Easy connectivity with two convenient USB ports on the front, two on the side 6. USBTMC (Test and Measurement...

 Open the catalog to page 4
WaveRunner 6 Zi Oscilloscopes-5

8. Deepest toolbox with more measurement, more math, more power 9. argest selection of serial triggers and L decoders—more than 17—available to provide a total system view 10. erial trigger captures signals up S to 3 Gb/s 11. avePilot consolidates important W oscilloscope debug features in one place. LEDs illuminate to indicate navigation options and active oscilloscope features 12. he SuperKnob provides joystick control T to easily navigation to key debug and documentation features 13. LBUS provides easy connection to the optional mixed signal feature, providing up to 36 digital channels 14....

 Open the catalog to page 5
WaveRunner 6 Zi Oscilloscopes-6

12-bit High Resolution Oscilloscope Features • 1 mV vertical Sensitivity @ full bandwidth WaveRunner HRO 6 Zi The WaveRunner HRO features an industry leading 12-bit Analog to Digital Convertor (ADC), deep memory of 256 Mpts/Ch, and superior DC accuracy specifications. These features are in addition to the extensive analysis features of the WaveRunner 6 Zi. Engineers no longer have to compromise high resolution for deep analysis. filters for additional noise filtering Full Scale Dynamic Range Resolution refers to the number of levels available. Number of levels = 2 bits of resolution Smallest...

 Open the catalog to page 6
WaveRunner 6 Zi Oscilloscopes-7

Capture a fast transient signal at the highest sample rate for the best resolution. Capture up to 30 seconds of data at sample rates as high as 10 MS/s for trending and searching for events. 256 Mpts/Ch Deep Memory High resolution applications typically require a very long acquisition, capturing up to 30 seconds of data to detect very slow or gradual changes. The 2 GS/s, 256 Mpts/Ch architecture provides the ability to capture a fast transient or a long acquisition. WaveRunner HRO 6 Zi Analysis Tools A common application for high resolution products is the ability to view a small amplitude signal...

 Open the catalog to page 7
WaveRunner 6 Zi Oscilloscopes-8

Deep insight to clarify complex signals More Trigger Capability Isolates More Problems More Quickly A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and triggerscan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution. A high-speed serial trigger enables triggering on up to 3 Gb/s serial patterns of up to 80-bits in length. A full range of serial...

 Open the catalog to page 8
WaveRunner 6 Zi Oscilloscopes-9

Display optimized for analysis Graphical Track, Trend, and Histogram Views Track plots measurement values on the Y-axis and time on the X-axis to display a measurement change time-correlated to the original channel acquisition—perfect for intuitive understanding of behaviors in frequency modulated (FM) or pulse width modulated (PWM) circuits and jitter measurements, including modulation or spikes. Histograms provide a visual distribution representation of a large sample of measurements, allowing faster insight. Trends are ideal for plotting slow changes in measurement values. Rotating Display...

 Open the catalog to page 9
WaveRunner 6 Zi Oscilloscopes-10

A total solution for serial data The WaveRunner 6 Zi features the most complete serial data solutions. Solving serial data problems requires intimate knowledge of the protocol to get started. With the WaveRunner 6 Zi, the oscilloscope is the expert. Simply connect your probes or cables and the scope can provide correct level of detail needed to view, debug, and analyze the serial data signals. Solutions address the Embedded, Military and Avionics, Handset/Mobile/ Cellular, and Storage/ Peripherals/Interconnects, with a combination of decode, trigger, measure/ graph, ProtoSync, and compliance...

 Open the catalog to page 10
WaveRunner 6 Zi Oscilloscopes-11

The integrated clock and jitter analysis tools use advanced jitter decomposition methodologies and tools to provide more information about root cause. TJ analysis, RjBUj analysis and DDj analysis is made simple with the deepest toolset dedicated to Compliance Automated compliance and testing is simplified with the QPHY software option. QPHY features automated scripts, connection diagrams, and test reports to greatly simplify the compliance process. Learn More teledynelecroy.com/serialdata Compatible with PCI Express, USB 2, SAS, SATA, and Fibre Channel. Measure /Graph ProtoSy nc QuailPHY Military...

 Open the catalog to page 11

All Teledyne LeCroy Europe catalogs and technical brochures

  1. T3DSO4000L-HD

    19  Pages

  2. HDO6000B

    20  Pages

  3. T3DAQ1-16

    16  Pages

  4. WavePro HD

    20  Pages

  5. WaveRunner 9000

    20  Pages

  6. DDR Test Suite

    12  Pages

  7. WaveRunner 8000

    24  Pages

  8. wavesurfer 510

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.