WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz
38Pages

{{requestButtons}}

Catalog excerpts

WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 1

HIGH BANDWIDTH, UNIQUELY VERSATILE

Open the catalog to page 1
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 2

Most Capability The most complete feature set on a high-bandwidth oscilloscope • Mixed signal • Both 50 Ω and 1 MΩ inputs for widest probe support acquisition capability serial triggering and decoding Serial Data & DDR Analyze the Whole Link at Once Unmatched high-speed serial tools • Simple and powerful compliance test automation • Most complete eye diagram, jitter and noise analysis • Fastest DDR Test Journey End-to-end link signal integrity analysis • Import S-parameter files from WavePulser 40iX and other instruments • De-embed fixtures • Measure transmitter and receiver equalization effe

Open the catalog to page 2
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 3

Uniquely Versatile High Bandwidth, Uniquely Versatile

Open the catalog to page 3
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 4

WaveMaster 8 Zi-B's unique combination of high-bandwidth performance (up to 20 GHz) and general purpose features enables the most compehensive validation and debug capabilities. This one oscilloscope platform covers low-speed and high-speed embedded systems, serial data analysis, and DDR debug. 50 0 and 1 MO Inputs for Widest Probe Support WaveMaster is the only high-bandwidth oscilloscope to also provide built-in 1 MQ inputs. This permits direct connection of passive probes, and support for the widest variety of low voltage, high voltage and current probes, all without requiring the use of...

Open the catalog to page 4
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 5

BEST FOR SERIAL DATA AND DDR The WaveMaster 8 Zi-B is the best oscilloscope platform for high-speed serial data and memory compliance and debug. The combination of general-purpose capabilities, mixed-signal options, low-speed serial triggers/decoders and comprehensive compliance, analysis and debug software options puts you in the drivers seat. QualiPHY Automated Compliance Testing HDMI™, DisplayPort™, Ethernet, Automotive Ethernet, DDR, and many other serial data standards • Fully automated transmitter and receiver testing and receiver test calibration • Step-by-step instructions and...

Open the catalog to page 5
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 6

ANALYZE THE WHOLE LINK Combining the WavePulser® 40iX High-speed Interconnect Analyzer, WaveMaster 8 Zi-B oscilloscope and SDAIII-CompleteLinQ option gives the most complete signal integrity analysis toolkit available. Quickly characterize the entire signal path from transmitter to receiver, acquire high-fidelity waveforms at a convenient test point, and then easily analyze the signal at any point of interest. Characterize Channel Fixture/ Test cables Acquire signal Fixture/ Test cables

Open the catalog to page 6
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 7

De-embed fixtures and test cables • Measure S-parameter models using WavePulser 40iX, or import from other measurements or simulation tools Fixture/ Test cables • Sophisticated Eye Doctor and VirtualProbe Fixture/ Test cables tools easily and accurately remove effects of fixtures and cables from acquired oscilloscope waveforms • Apply the full SDAIII-CompeteLinQ toolkit to de-embedded waveforms for full eye, jitter and noise analysis directly at the output pins of the device under test Acquire signal De-embed channel Emulate real-world channel losses • WavePulser 40iX simplifies and speeds...

Open the catalog to page 7
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 8

Data dependent jitter (DDj) plot for each bit in synch with pattern (a) and with histogram (b) Time interval error (TIE) jitter track analysis Jitter histograms (a) with bathtub curves (b) and CDF plot (c) Key Attributes 1. Eye diagram (a), eye mask failure 3. (b) and IsoBER eye opening analysis (c) 2. Jitter spectrum (a) with noise floor 4. display (b) and inverse FFT of the periodic jitter (c) 5 6. Intersymbol interference (ISI) plots pinpoint bit sequences that have high ISI and are sources of bit errors 7. Jitter measurements table with full details for one or more “lanes” plus...

Open the catalog to page 8
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 9

COMPREHENSIVE SERIAL DATA ANALYSIS Fast Single or Multiple Eye Diagrams • Up to four real-time and one reference • Single lane with multiple-point or multiconfiguration analysis • Analyze multiple lanes simultaneously • Fast eye diagram creation • Reference lane simplifies multi-scenario testing • IsoBER displays expected eye infringement to a user-settable bit error rate (BER) Use the unique crosstalk eye to view and compare noise in a way that cannot be done with a traditional eye diagram. • Crosstalk eye contour plots display the impact of excessive noise Comprehensive Jitter...

Open the catalog to page 9
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 10

FASTEST DDR TEST JOURNEY The DDR test journey can be quick when the right tools for engineers enable smooth transitions from all stages of design, DDR turn-on, initial validation testing to fine-tuning, optimizing, pre-compliance and final compliance. Accelerate testing by confidently testing designs quickly and easily. Teledyne LeCroy covers BGA testing tools for JEDEC standards such as DDR2/3/3L/4/5 and LPDDR2/3/4/4X. 3. ools for Turn-on Through Pre-compliance T – Interposers from reliable partners (Nexus and EyeKnowHow) – Multi-scenario viewing fast-tracks testing – Exclusive toolkit...

Open the catalog to page 10
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 11

Decode and Trigger Establishing basic operation, signal checks and responses is the foundation of board turn-ons. Decode the command bus to understand if it's correctly communicating and know if Read and Write packets are present. • Industry's only decode & trigger up to DDR5 • Decode 20+ packets from JEDEC Command Truth Table • Perform better R/W separation using the command bus • Overlay Read/Write visuals on channels • Trigger on six different bus packet types (Command (DQ Write, Eye (DQ Read, Add. Decode and Jitter Eye and Jitter and Table) analysis) analysis) Measurement compare across...

Open the catalog to page 11
WaveMaster 8 Zi-B Oscilloscopes 4 GHz–30 GHz - 12

Automated Transmitter, Receiver and Link Equalization (LEQ) testing with QualiPHY software options Visibility from physical layer through protocol operations WaveMaster/SDA 8 Zi-B is gold suite certified for all relevant PCI Express 3.0 (8 GT/s) tests Transmitter (Tx) Testing • Base specification and compliance testing for add-in cards and systems in CEM, M.2 and U.2 form factors • QualiPHY fully automates collection and processing of transmitter waveforms • Supports TF-PCIE4-CTRL controller for full fixture and DUT automation • Debug electrical compliance issues faster with...

Open the catalog to page 12

All Teledyne LeCroy Europe catalogs and technical brochures

  1. T3DSO4000L-HD

    19 Pages

  2. HDO6000B

    20 Pages

  3. T3DAQ1-16

    16 Pages

  4. WavePro HD

    20 Pages

  5. DDR Test Suite

    12 Pages

  6. wavesurfer 510

    20 Pages

  7. Voyager M3i

    8 Pages

  8. SPARQ

    12 Pages

  9. LogicStudio

    8 Pages

  10. ArbStudio

    8 Pages

Archived catalogs