WaveJet Touch Oscilloscopes 350 MHz / 500 MHz 50 MHz and 500 MHz bandwidths 3 p to 2 GS/s sample rate U The WaveJet Touch provides the performance, features, and touch screen user interface to simplify operation and shorten debug time. The .5” touch screen display 7 6 measurement parameters 2 compact design features a 7.5” touch screen, providing the convenience of touch operation in a portable design. With up to 5 Mpts of memory and 2 GS/s, every detail of the waveform can be captured and easily measured. The all-inclusive WaveJet Touch delivers maximum value for tandard Pass/Fail Mask and S minimum investment. Measurement testing tandard USB Host, USB Device, S ltra-quick boot time U serial triggers GPIB, and LAN connectivity and help Touch Screen Control Portable Performance Touch screen operation simplifies The small form factor and light-weight design make it easy to carry and use are controlled, increasing productivity anywhere. Coupled with an ultra-quick and decreasing setup time. Intuitively boot time, the WaveJet Touch is ready touch controls instead of navigating to use when needed. The WaveJet confusing soft keys. Touch is on and acquiring signals in Shorten Debug Time Intricate signals can be quickly acquired less than 5 seconds, enabling measurements to begin immediately. by combining a long capture time with Flexible Connectivity a variety of complex triggers, including Easily document results by saving screenshots directly to a memory stick Pass/fail mask and measurement or printer. Standard GPIB, LAN, and testing enables deeper analysis and USB connections enable easy remote performs characterization and valida- control. Using Teledyne LeCroy’s tion testing with ease. Scroll back in WaveStudio the WaveJet Touch can time to view previous waveforms and isolate anomalies using Replay mode.
Open the catalog to page 1ADVANCED TOOLS FOR WAVEFORM ANALYSIS Long Capture Time Long memory is critical for maintaining high sample rate during long data captures. The standard 5 Mpts of memory eliminates the tradeoff between long capture and high sample rate. The long memory makes the WaveJet Touch a great tool for viewing signals that have low frequency and high frequency components. The built-in zoom function provides an easy way to get a close look at all of the signal details. Advanced Triggering Digital Filtering Multiple Acquisition Modes Equipped with a variety of complex Digital filtering is available on each...
Open the catalog to page 2Waveform Math and Analysis Math operators include basic arith- metic functions and advanced FFT, derivative, and integral functions. Advanced math can be performed on the results of basic math functions. The scaling and offset of the math trace can easily be adjusted with its Pass/Fail Testing Waveforms can be tested against a mask or measurement parameters can be assigned pass/fail criteria for validation testing. On a pass/fai configured to: stop the acguisition, beep, save the waveform, take a screen capture or output a pulse to another instrument. Automatic Measurements Measure waveforms...
Open the catalog to page 3TT-TELEDYNE LECROY WaveJet Touch 354 sooMHz oscilloscope The WaveJet Touch delivers the performance, features, and touch screen user interface to simplify operation and shorten debug time. 1. 7.5" Touch Screen - Directly touch the display for a simplified user experience. 2. Ultra-quick Boot Time - The WaveJet Touch is on and ready to acquire waveforms in less than 5 seconds. 3. Connectivity - Documenting results is easy using the front-mounted USB port. Simply press the Print button on the front panel to quickly save screen images. 4. Portability - The small footprint and light weight of the...
Open the catalog to page 4SETUP PRINT UTILITIES WSPLAY HECALL MENU HELP CLEAR (ETUP NORMAL STOP SINGLE SETUP ZOOM 7. Replay Control - Rotate to see a history of captured waveforms. Independent Vertical Controls - Quickly change the vertical scale of any channel. Push Knobs - Push the Offset knobs to automatically zero the channel offset or push the Delay knob to center the trigger point on 10. GPIB and LAN Ports - Standard connectivity for easy remote control and data transfer. 11. USB Host Port - Can be configured to print a hardcopy or an interface for remote control. 12. Auxiliary Output - Send a trigger out or pass/fail...
Open the catalog to page 5ACCESSORIES LogicStudio The WaveJet Touch can be paired with Teledyne LeCroy’s LogicStudio 16 to turn your PC into a mixed signal oscilloscope with tools for capturing, viewing, and measuring analog, digital, and serial signals in one place. LogicStudio offers 16 channels, 100 MHz, and up to 1 GS/s logic analysis with I2C, SPI, and UART triggering and decoding which can all be displayed alongside the analog waveforms captured on WaveJet Touch. When only digital debug is needed disconnect the WaveJet Touch and use LogicStudio as a standalone logic analyzer. Soft Carrying Case The small form factor...
Open the catalog to page 6SPECIFICATIONS WaveJet Touch 334 350 MHz 1 ns (typical) Bandwidth (@50 Ω) Rise Time Input Channels Vertical Resolution Sensitivity DC Gain Accuracy Bandwidth Limiting Filter Maximum Input Voltage Input Coupling Input Impedance Offset Range Offset Accuracy Sampling Rate (Single Shot) Sampling Rate (Equivalent Time) Record Length Acquisition Modes Real Time Timebase Range Roll Mode Timebase Range Peak Detect Period Timebase Accuracy Standard Probes Probing System Trigger System Modes Sources Coupling Trigger Types I2C WaveJet Touch 354 500 MHz 750 ps (typical) 8-bits 50 Ω: 2 mV/div – 2 V/div; 1M...
Open the catalog to page 7SPECIFICATIONS & ORDERING INFORMATION Specifications (cont’d) Input/Output Interfaces Aux Out USB LAN GPIB Environment Temperature Humidity Altitude Power Requirements Voltage Power Consumption (Max) Trigger output or pass/fail output USB host port for flash drives, USB device port for connecting to PC and direct printer connection 10/100Base-T Ethernet interface (RJ-45 connector) Supports IEE-488.2 7.5"H x 13"W x 4.9"D (190 mm x 330 mm x 124 mm) 3.7 kg (8.16 lbs) Operating: 0 °C to 40 °C; Non-Operating: -20 °C to 60 °C Maximum 80% relative humidity (non-condensing) up to ≤ 30 °C, Upper limit...
Open the catalog to page 819 Pages
20 Pages
20 Pages
15 Pages
16 Pages
6 Pages
8 Pages
4 Pages
20 Pages
20 Pages
16 Pages
12 Pages
28 Pages
24 Pages
20 Pages
8 Pages
4 Pages
2 Pages
12 Pages
2 Pages
4 Pages
36 Pages
36 Pages
36 Pages
36 Pages
36 Pages
28 Pages
28 Pages
28 Pages
8 Pages
20 Pages
20 Pages
28 Pages
16 Pages
2 Pages
8 Pages
12 Pages
8 Pages
2 Pages
7 Pages
4 Pages
4 Pages
2 Pages
4 Pages
8 Pages
8 Pages
12 Pages
8 Pages