
Catalog excerpts

HDO8000 High Definition Oscilloscopes • 8 analog channels • 12-bit ADC resolution, up to HDO8000 High Definition Oscilloscopes have more channels, more power three-phase power electronics, automotive electronics, and 15-bit with enhanced resolution 1 GHz bandwidths • Long Memory – up to 250 Mpts/Ch • 16 Digital Channel MSO option • Q-Scape™ Multi-tab display architecture resolution, more bandwidth and more memory than any other midrange oscilloscope. Ideal for debugging and troubleshooting high embedded/mechatronic designs with high resolution sensor signals. Comprehensive digital logic (MSO), low-speed serial data trigger, decode and analysis toolsets, and the widest variety of probes and application packages complete the solution. Get the most intuitive long-memory analysis using the unique Q-Scape multi-tab display architecture. HD4096 high definition technology Q-Scape Multi-tab Display Architecture consists of 12-bit ADCs with (2.5 GS/s) More waveforms requires new display sample rates, high signal-to-noise architectures. Unique Q-Scape multi- (55dB) input amplifiers and a low-noise tab display architecture speeds your system architecture. This technology understanding of your design with enables high definition oscilloscopes to 4x the display area. Quickly move • Advanced analysis and reporting capture and display signals of up to waveforms to different tabs through 1 GHz with 16 times more resolution drag-and-drop. Extended desktop • Advanced Triggering supplemented than conventional 8-bit oscilloscopes. 1 2.1” WXGA touch screen display with WQXGA 3840 x 2160 pixel extended-desktop mode • Wide probe selection for power electronics, embedded electronics, and mechatronics applications toolsets with TriggerScan and Measurement Trigger • Serial Data Trigger, Decode and Debug Toolkit Options Long Memory pixel displays. Capture large amounts of data with Comprehensive Analysis Tools more precision using the 250 Mpts of acquisition memory. Zoom in for detail, trigger, decode, math, measurement, use Roll Mode for extremely long time and application toolsets available. periods, or 2.5 GS/s for capturing fast Use tracks, trends and histograms to transients and slow events together enhance understanding of complex over longer periods than ever behaviors. LabNotebook concisely before possible. documents and stores your results.
Open the catalog to page 1
MAXIMUM PERFORMANCE HDO8000 High Definition Oscilloscopes provide more channels, more resolution, more bandwidth and more memory. They are ideal for debugging three-phase power electronics, automotive electronics, and mechatronic systems. Mixed Signal capability allows users to simultaneously analyze 8 Analog inputs and 16 Digital inputs. Serial data Trigger, Decode, and Analysis toolsets aid in debugging embedded systems. The unique Q-Scape multi-tab display makes it easy to work with multiple channels, and the solution is completed by a wide variety of probes and application packages....
Open the catalog to page 2
FURTHER, FINER, FASTER High-Power, Three-Phase Power Electronics is increasing the demand for invert- ers and converters to interface these 250 Mpts/ch of memory permits Variable frequency motor drive de- power sources to the grid, and is also the most comprehensive analysis signs are increasingly down-deployed driving new power electronics solu- of mixed low-speed and high-speed in lower cost applications, but with tions to compensate, regulate and events over long periods of time. increasing control complexity. Distrib- control the power flow from large uted electric power generation...
Open the catalog to page 3
HDO8000 - 8 CHANNEL, 12-BIT HIGH DEFINITION HDO8000 High Definition Oscilloscopes provide the right capabilities for debug and troubleshooting of high power three-phase power electronics, automotive electronics, and challenging embedded or mechatronic designs. 1. analog input channels 8 1 2. 2-bit HDO4096 technology - 16x closer to perfect 3. p to 1 GHz - enough bandwidth for today and U tomorrow 1 4. 2.1” Widescreen (16 x 9) WXGA color touch screen display - WQXGA (3840 x 2160) extended-desktop display. 5. -Scape multi-tab display architecture - 4x the Q display area 6. ntel® Core™...
Open the catalog to page 4
MIXED SIGNAL OSCILLOSCOPE 10. uilt-in stylus to use with the most advanced B user interface 11. Push” Knobs – shortcuts to common actions “ such as Set to Variable, Find Trigger Level, Zero Offset, and Zero Delay 12. aveform Control Knobs – Control channel, W zoom, math and memory traces with the multiplexed vertical and horizontal knobs 13. edicated Cursor Knob – Select type of cursor, D position them on your signal, and read values without ever opening a menu 14. edicated buttons to quickly access popular D debug and documentation tools and Q-Scape displays 15. uxiliary Output and...
Open the catalog to page 5
HD4096 TECHNOLOGY - 16X CLOSER TO PERFECT High Signal to Noise Input Amplifiers Teledyne LeCroy HDO high definition oscilloscopes use unique HD4096 technology to provide superior and uncompromised measurement performance: – 12-bit ADCs with high (2.5 GS/s) sample rates – High signal-to-noise amplifiers (55 dB) – Low noise system architecture (to 1 GHz) High Sample Rate 12-bit ADC’s Oscilloscopes with HD4096 technology have higher resolution than conventional 8-bit oscilloscopes (4096 vs. 256 vertical levels) and low noise for uncompromised measurement performance. The 2.5 GS/s, 12-bit ADCs...
Open the catalog to page 6
Experience HD4096 accuracy, detail, and precision and never use an 8-bit oscilloscope again. Whether the application is general-purpose design and debug, high-precision analog, power electronics, automotive electronics, mechatronics, or other specialized applications, the HD4096 technology provides unsurpassed confidence and measurement capabilities. Clean, Crisp Waveforms More Signal Details When compared to waveforms acquired 16x more resolution provides more signal Unmatched Measurement Precision and displayed using conventional 8-bit detail. This is especially helpful for wide HD4096...
Open the catalog to page 7All Teledyne LeCroy Europe catalogs and technical brochures
-
T3DSO4000L-HD
19 Pages
-
WaveRunner 8000HD
20 Pages
-
HDO6000B
20 Pages
-
T3DSOH1000 /T3DSOH1000-ISO
15 Pages
-
T3DAQ1-16
16 Pages
-
T3MIL50 Milli Ohm Meter
6 Pages
-
T3PM1006 Digital Power Meter
8 Pages
-
Current Probes
4 Pages
-
WavePro HD
20 Pages
-
WaveRunner 9000
20 Pages
-
PeRT3 Phoenix System
16 Pages
-
DDR Test Suite
12 Pages
-
LabMaster 10 Zi-A
28 Pages
-
WaveRunner 8000
24 Pages
-
wavesurfer 510
20 Pages
-
MDA800 Motor Drive Analyzers
8 Pages
-
MIPI M-PHY Protocol Analyzer
4 Pages
-
Transmission Line Probes
2 Pages
-
WaveSurfer 10 Oscilloscope
12 Pages
-
Summit T24 Analyzer
2 Pages
-
SierraNet M168
4 Pages
-
LabMaster 10 Zi Oscilloscopes
36 Pages
-
LabMaster 9 Zi-A Oscilloscopes
36 Pages
-
WaveMaster 8 Zi-A Oscilloscopes
36 Pages
-
SDA 8 Zi-A Serial Data Analyzers
36 Pages
-
DDA 8 Zi-A Disk Drive Analyzers
36 Pages
-
WavePro 7 Zi-A Oscilloscopes
28 Pages
-
SDA 7 Zi-A Serial Data Analyzers
28 Pages
-
DDA 7 Zi-A Disk Drive Analyzers
28 Pages
-
HRO 12-bit Oscilloscopes
8 Pages
-
HDO6000 / HDO6000-MS High
20 Pages
-
WaveRunner 6 Zi Oscilloscopes
28 Pages
-
HDO4000 / HDO4000-MS High
16 Pages
-
WaveSurfer 3000 Oscilloscopes
12 Pages
-
WaveJet 300A Oscilloscopes
8 Pages
-
Summit T3-16 Analyzer
2 Pages
-
Voyager M3i
8 Pages
-
Differential Amplifiers
2 Pages
-
Current Probes
7 Pages
-
HFP SERIES ACTIVE PROBES
4 Pages
-
LeCroy Kibra 480 Analyzer
4 Pages
-
Vehicle Bus Analyzers
2 Pages
-
Signal Integrity Studio
4 Pages
-
SPARQ
12 Pages
-
LogicStudio
8 Pages
-
ArbStudio
8 Pages
-
PeRT3 Eagle System
8 Pages