TELEDYNE LECROY Everywhereyoulook™ DCS025 Deskew Calibration Source Key Features 10 ns signal fall time Only 1 ns static skew 5 V and 100 mA time-aligned output signals Loop size compatible with 30, 150 and 500A current probes The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes. This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements. Compatible with standard and high-sensitivity current probes Simple to Use A voltage probe connects to the voltage pulse signal and ground connection and a current probe connects around the current pulse loop. Propagation delay differences between the two probes are then measured and manually deskewed by the operator using the Deskew adjustment in the oscilloscope's Channel setup dialog. Large Current Loop The DCS025 has a large current loop that is compatible with Teledyne LeCroy small (e.g., CP03x) and large sized current probes (e.g., CP150, CP500). Channel acquisition averaging permits measurement of the output current amplitude with higher amperage current probes. Low Static Skew The internal static skew of the DCS025 is only 1 ns - well-matched to the rise times of the DCS025 and the probes commonly used for power semiconductor device loss measurements. Automatic Triggering Setup The DCS025 connects to the EXT input of the oscilloscope and outputs a trigger signal to simplify time alignment and deskew operations to the signal fall time at the center of the oscilloscope display.
Open the catalog to page 1CP030 30A current probe and HVD3106 high voltage differential probe connected to an HDO6104A-MS 12-bit resolution high definition oscilloscope. The DCS025 is connected to the EXT input (to conserve analog channels) and the deskew amount is adjusted for one of the probes in the channel dialog menu. CP150 150A current probe and HVD3106 high voltage differential probe connected to an HDO6104A-MS 12-bit resolution high definition oscilloscope. The DCS025 is connected to the EXT input (to conserve analog channels) and the deskew amount is adjusted for one of the probes in the channel dialog menu....
Open the catalog to page 219 Pages
20 Pages
20 Pages
15 Pages
16 Pages
6 Pages
8 Pages
4 Pages
20 Pages
20 Pages
16 Pages
12 Pages
28 Pages
24 Pages
20 Pages
8 Pages
4 Pages
2 Pages
12 Pages
2 Pages
4 Pages
36 Pages
36 Pages
36 Pages
36 Pages
36 Pages
28 Pages
28 Pages
28 Pages
8 Pages
20 Pages
20 Pages
28 Pages
16 Pages
2 Pages
8 Pages
12 Pages
8 Pages
2 Pages
7 Pages
4 Pages
4 Pages
2 Pages
4 Pages
8 Pages
8 Pages
12 Pages
8 Pages