Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology. Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements Key Features • ProBus active probe interface with automatic scaling in A/div • Autozero and degauss capabilities built into instrument’s user interface • CP030 — 30 Arms continuous current — 50 Apeak current — 50 MHz bandwidth • CP030A — 30 Arms continuous current — 50 Apeak current — 50 MHz bandwidth — 1 mA/div sensitivity • CP031 — 30 Arms continuous current — 50 Apeak current — 100 MHz bandwidth • CP031A — 30 Arms continuous current — 50 Apeak current — 100 MHz bandwidth — 1 mA/div sensitivity • CP150 — 150 Arms continuous current — 500 Apeak current — 10 MHz bandwidth • CP500 — 500 Arms continuous current — 700 Apeak current — 2 MHz bandwidth Wide Range of Applications Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies. High Sensitivity The CP030A and CP031A provide a high sensitivity of 1 mA/div. This allows for more precise low current measurements on Teledyne LeCroy oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug Fully Integrated All Teledyne LeCroy current probes are powered through the Teledyne LeCroy ProBus® connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for Degauss and Autozero functions to be done directly from the oscilloscope's user interface. Deskew Calibration Source The DCS025 deskew calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with 30, 150 and 500A current probes are compatible with the DSC025.
Open the catalog to page 120 Current (Arms) Current 20 15 (Arms) Current 20 (Arms) 20 Current 15 (Arms) Current (Arms) Maximum Input Current vs. Frequency* Insertion Impedance 0.1 Insertion Impedance 0.1 Insertion Impedance 0.1 Insertion Impedance 0.1 Maximum Input Current vs. Frequency Current (Arms) Insertion Impedance vs. Frequency (typical) Insertion Impedance Insertion Impedance vs. Frequency* (typical) *This performance does not apply to CP030-3M model.
Open the catalog to page 2Current Current (Arms) 100 ) (Arms 80 Current (Arms) 80 Current (Arms) Current (Arms) Current (Arms) Current (Arms) Maximum Input Current vs. Frequency* Maximum Input Current vs. Frequency 1010 (Hz) M Frequency Frequencyk (H Frequency (Hz) Insertion 0.1 Insertion Impedance Impedance Insertion Impedance Insertion Impedance Insertion Impedance Insertion Impedance Insertion Impedance Insertion Impedance Insertion Impedance vs. Frequency* (typical) *This performance does not apply to CP150-6M model. Insertion Impedance vs. Frequency (typical)
Open the catalog to page 3Specifications Electrical Characteristics* Max. Continuous Input Current_ Rise Time (typical) < 35 ns _(< 70 ns)_ 300 Apeak (non-continuous); 50o Apeak < 30 ps Output Voltage_ Max Continuous Input Current at 1 V/A (100mA/div or less) Offset Range at 1V/A (100mA/div or less)_ Minimum Sensitivity_ Low-Frequency Accuracy AC Noise at 20 MHz BWL Coupling General Characteristics_ _(290 g) Max. Conductor Size (Diameter)_ Usage Environment_ Operating Temperature Max. Relative Humidity_ Maximum Insulated Wire Voltage_ * Electrical Characteristics Guaranteed at 23 °C ±3 °C ProBus, 1 MQ only _Indoor_ 0°...
Open the catalog to page 419 Pages
20 Pages
20 Pages
15 Pages
16 Pages
6 Pages
8 Pages
20 Pages
20 Pages
16 Pages
12 Pages
28 Pages
24 Pages
20 Pages
8 Pages
4 Pages
2 Pages
12 Pages
2 Pages
4 Pages
36 Pages
36 Pages
36 Pages
36 Pages
36 Pages
28 Pages
28 Pages
28 Pages
8 Pages
20 Pages
20 Pages
28 Pages
16 Pages
2 Pages
8 Pages
12 Pages
8 Pages
2 Pages
7 Pages
4 Pages
4 Pages
2 Pages
4 Pages
8 Pages
8 Pages
12 Pages
8 Pages