Signature Flow Meter - 1

TIENetTM Model 310 Ultrasonic Level Sensor Flow Accuracy Measurement Range 0.3 to 3.3m (1 to 11 ft) Accuracy at 72°F (22°C) ±0.006m (0.02 ft) at 1 ft level change ±0.009m (0.03 ft) > 1 ft level change ±0.0002 x Distance (m) x TemperaTemperature ture Deviation from 22 °C. Coefficient ±0.00011 x Distance (ft) x Tempera(w/ in compensated ture Deviation from 72 °F. range) Beam Angle 10° (5° from center line) Frequency 50 kHz Size 9.1 cm X 10.2 cm tall (3.63“x 4“) Cable Length 10 or 23m (32.8 or 75.5 ft) Weight 1.8 kg (4 lbs) Body Material PVDF Temperature Range -30° to 60°C (-22° to 140°F) (Operating & Storage) Certifications Group 2, Category 1G (zone 0), T4 Class I, Div 1, Groups C & D, T4 (pending) Velocity Measurement Range Direction TIENetTM 330 Bubbler Module TIENetTM Model 350 Area Velocity Sensor Level Measurement Range: Level Measurement Accuracy Operating and Storage Temperature Temperature Compensation Range Temperature Coefficient (w/in compensated range) Probe Dimensions Temperature Range Velocity Measurement Range Velocity Measurement Velocity Accuracy 0° to 60°C (32° to 140°F) ±0.0003 x Level (m) x Temperature Deviation from 22 °C. ±0.00017 x Level (ft) x Temperature Deviation from 72 °F. TIENetTM Model 360 LaserFlow Velocity Sensor Sensor Dimensions Weight Materials Temperature Range Cable Lengths Enclosure Certifications Power Required 38.01 x 26.21 x 56.7 cm 14.96 x 10.3 x 22.32 in 8.7 kg (19.2 lbs) Conductive Carbon Filled ABS, SST, Conductive Kynar, Anodized Aluminum, UV-Rated PVC Operating: 0 to 60 °C (32 to 140 °F) Storage: -40 to 60 °C (-40 to 140 5, 10, or 15 m (16.4, 32.8, or 49.2 ft) IP68 CE EN61326; FDA CDRH 21CFR1040; IEC 60825-1 Input voltage: 8 to 26 VDC 12VDC Nominal Velocity Accuracy Minimum Velocity Level Measurement Range Level Accuracy @ 22 °C (72 °F) Temperature Coefficient within compensated range Beam Angle Ultrasonic Signal Minimum Depth Frequency Level Measurement Range Level Accuracy Maximum Allowable Depth Typical Long-Term Stability ±5% of Reading. (Typical, under normal flow conditions) -4.6m/s to 4.6 m/s (-15 ft/s to 15 ft/s) Bi-Directionala ±0.5% of reading ±0.03 m/s (0.1 ft/s) 0.25 m/s (0.8 ft/s) 0 to 3 m (0 to 10 ft) from measurement point ±0.006 m (0.02 ft) at 1 ft level change; ±0.012 m (0.04 ft) at 1 ft level change ± 0.0002 x D (m) per degree C ± 0.00011 x D (ft) per degree F (Where D = Distance from transducer to liquid surface) 10° (5° from center line) 50KHz 1.9 x 3.3 x 15.2 cm (0.75 x 1.3 x 6.0 in) Sensor: Epoxy, chlorinated PC, SST. Cable: UV-Rated PVC 0 to 70 °C (32 to 158 °F) -1.5 to 6.1m/s (-5 to 20 ft/s) Bi-Directional ±0.03 m/s (±0.1 ft/s) from -5 to 5 ft/s ±2% of reading from 5 to 20 ft/s, Uniform velocity profile 25 mm (0.08 ft) 500 kHz 0.01 to 3.05 m (0.033 to 10 ft) Signature® Flow Meter The Signature flow meter is designed for open channel flow monitoring applications. It supports flow measurement technologies including bubbler, noncontact laser area velocity, submerged Doppler ultrasonic area velocity, and ultrasonic. The meter can calculate flow using standard open channel level-to-flow and area velocity conversions, as well as user-defined equations, level to area data points, or level to flow data points, depending on the application need. The Signature flow meter has unique features to verify data integrity. It logs key events such as changes in calibration and power outages to validate data accuracy. Data can be easily reviewed to detect any type of data alteration. With multiple smart interface options and multiparameter logging (such as pH), the Signature flow meter provides a common platform for control action, reporting, and communication. IP66/NEMA 4X panel offers protection against entry of dust or water during meter programming I/O Features Multiple simultaneous flow technologies pH and temperature input SDI-12 input Available Measurement Technologies Bubbler Ultrasonic Non-Contact Laser Velocity Continuous Wave Area Velocity Analog outputs (Optional card required) Communication/Interface Features Ethernet modem Industrial Pretreatment Compliance Cellular modem options Shallow flow measurement in large and small Permit Enforcement a. Turbidity > 20 NTU; Distance from liquid surface to bottom of sensor < 48 inches b. Maximum non-linearity, hysteresis, & temperature error from actual liquid level. Teledyne Isco 4700 Superior Street USA and Canada (800) 228-4373 Lincoln, NE 68504 USA Fax: (402) 465-3022 Tel: (402) 464-0231 E-Mail: IscoInfo@teledyne.com Teledyne Isco reserves the right to change specifications without notice. ©2012 Teledyne Isco L-2153 09/12 pipes Wastewater Treatment Plants Outfall General Features Multiple parameter data logging Program and Summary Reports Data Integrity Verification Triggering, sampler enabling Compatibility with Flowlink® software

Open the catalog to page 1
Signature Flow Meter - 2

Remote Communication Signature Flow Meter Connectivity and Interface Options Flowlink Software Modbus/ SCADA Ethernet Network Internet Accessible Data Cellular Modem Communication Sampler Interface Base Meter Network Communication Ultrasonic Level Sensor LaserFlow Velocity Sensor Area Velocity Sensor Bubbler Level Sensor Modbus Input Smart TIENetTM Devices TIENet input and output devices utilize a common, proprietary interface protocol Low system integration cost with multiple measurement technologies, I/O protocols, and communication options Configurable and upgradable without hardware or...

Open the catalog to page 2

All Teledyne Isco catalogs and technical brochures

  1. ReaXus 6010R

    2 Pages

  2. L1150 AQ700

    2 Pages

  3. ELSD

    4 Pages

  4. Combiflash

    2 Pages

Archived catalogs