ISCO 4100 SERIES FLOW LOGGERS
16Pages

{{requestButtons}}

Catalog excerpts

ISCO 4100 SERIES FLOW LOGGERS - 1

ISCO 4100 S ERIES FLOW LOGGERS The Ultimate System for Multi-Site Flow Monitoring and Analysis s Multiple Measurement Technologies s Large, Versatile Memory s Advanced Data Analysis s Up to One Year Battery Life s Rugged, Submersible Enclosure

Open the catalog to page 1
ISCO 4100 SERIES FLOW LOGGERS - 2

Isco Flow Loggers provide dependable long-term performance in tough sewer environments.

Open the catalog to page 2
ISCO 4100 SERIES FLOW LOGGERS - 3

he new 4100 Series Flow Loggers are battery-powered, open channel flow meters sealed in rugged, submersible enclosures. They store flow, rainfall and sample data in their large, versatile memory. With Isco Flowlink® Software on your PC, you can set up your Flow Loggers, retrieve and analyze stored data, and generate informative graphs and reports. Isco Flow Loggers are the ultimate system for collecting and analyzing data from multiple sites. Applications of the 4100 Series include: Treatment capacity analysis Peak flows and long-term flow patterns must be measured to guide the expansion of...

Open the catalog to page 3
ISCO 4100 SERIES FLOW LOGGERS - 4

Superior features and performance he new Isco 4100 Series Flow Loggers have all the features you need to handle the most demanding projects. Large, Versatile Memory The large memory and long battery life of the Flow Loggers substantially reduce the need to visit flow monitoring sites to replace batteries and retrieve data. Internal memory stores over 100,000 readings of flow, rainfall and sample data. Stored data is retrieved and analyzed using Isco Flowlink Software on your PC. For more information on data storage and Flowlink Software, see page 11. Up to One Year Battery Life The highly...

Open the catalog to page 4
ISCO 4100 SERIES FLOW LOGGERS - 5

Choose the best technology for your applications o single measurement technology is suitable for all open channel flow monitoring applications. Only Isco offers you a choice of ultrasonic, submerged probe, bubbler, variable gate and area velocity flow meters. The 4100 Series includes the 4110 Ultrasonic, 4120 Submerged Probe and 4150 Area Velocity Flow Loggers. Now you can choose the most accurate technology for each of your monitoring sites. s 4110 Ultrasonic — for flow measurement in streams containing harsh chemicals, grease or suspended solids. The ultrasonic sensor is mounted above the...

Open the catalog to page 5
ISCO 4100 SERIES FLOW LOGGERS - 6

4110 Ultrasonic Flow Logger he Isco 4110 Ultrasonic Flow Logger features a non-contacting sensor that quickly and easily installs above the flow stream. The 4110 sensor is not affected by flow stream chemicals or high concentrations of grease, suspended solids or silt. This gives you long-term dependability with no need for scheduled maintenance. Rugged, Dependable Sensor The 4110 uses a single-head sensor sealed in a rugged, corrosion resistant enclosure. The sensor transmits a sound pulse which is reflected from the surface of the flow stream. The elapsed time between sending a pulse and...

Open the catalog to page 6
ISCO 4100 SERIES FLOW LOGGERS - 7

Isco 4110 Flow Logger Specifications Flow Logger Size Weight (without batteries) Material Body and battery end Connector end Type (self-certified) Power Length 6.9 in. Diameter 3.6 in. Cable Length 25 ft. Structural foam molded polystyrene Cable Diameter 0.3 in. Ryton® (polyphenylene sulfide) Weight (including cable) 2.6 lbs. NEMA 4X, 6 IP67 Range (distance from sensor to liquid) Minimum 2 ft. Two 6 volt lantern batteries (alkaline recommended) or one rechargeable 12 volt Isco 947 Lead Acid Battery Maximum 12 ft. Typical Battery Life (event inputs will shorten battery life) Span 0 to 10 ft....

Open the catalog to page 7
ISCO 4100 SERIES FLOW LOGGERS - 8

4120 Submerged Probe Flow Logger he 4120 provides accurate measurement, even where wind, steam, foam, turbulence or air temperature fluctuations exist. Accurate Under Tough Conditions The Isco 4120 probe uses an integral differential pressure transducer to measure the depth of the liquid. The probe features a streamlined, low-profile design to minimize flow stream obstruction. Its venting system automatically compensates for changes in atmospheric pressure to maintain measurement accuracy. The probe accurately senses pressure even when covered with silt and sand. Safe for Hazardous...

Open the catalog to page 8
ISCO 4100 SERIES FLOW LOGGERS - 9

Isco 4120 Flow Logger Specifications Flow Logger Size Weight (without batteries) Material Body and battery end Connector end Type (self-certified) Power Structural foam molded polystyrene Ryton (polyphenylene sulfide) NEMA 4X, 6 IP67 Two 6 volt lantern batteries (alkaline recommended) or one rechargeable 12 volt Isco 947 Lead Acid Battery Typical Battery Life (event inputs will shorten battery life) Minimum data storage interval 1 hour 15 minutes Alkaline lantern batteries 2 years Isco 947 Lead Acid Battery 8 months (time between recharges) Program Memory Non-volatile, programmable flash;...

Open the catalog to page 9
ISCO 4100 SERIES FLOW LOGGERS - 10

4150 Area Velocity Flow Logger he Isco 4150 Flow Logger features a patent-pending Doppler system that eliminates the problems of electromagnetic probes. The 4150 gives you greater accuracy under tough open channel conditions, including submerged, full pipe, surcharged and reverse flow. And, you don’t need a weir or flume. Maximum Accuracy The 4150 calculates flow rate by multiplying the area of the flow stream by its average velocity. The Isco Doppler sensor directly measures average velocity throughout the flow stream, while an integral pressure transducer measures liquid depth to...

Open the catalog to page 10
ISCO 4100 SERIES FLOW LOGGERS - 11

Isco 4150 Flow Logger Specifications Area Velocity Sensor Flow Logger Length 6.6 in. 16.8 cm Width 1.6 in. 4.1 cm Height 1.2 in. 3.0 cm Structural foam molded polystyrene Nose Angle 35° from horizontal Ryton (polyphenylene sulfide) Cable Length NEMA 4X, 6 IP67 Standard range probe 25 ft. 7.6 m Two 6 volt lantern batteries (alkaline recommended) Extended range probe 50 ft. 15.2 m or one rechargeable 12 volt Isco 947 Lead Acid Battery Cable Diameter 0.37 in. 0.9 cm Typical Battery Life (event inputs will shorten battery life) Weight (including cable) Minimum data storage interval Standard...

Open the catalog to page 11
ISCO 4100 SERIES FLOW LOGGERS - 12

Isco Flowlink Software sco Flowlink Software is a new generation of flow data analysis software for your PC. Flowlink Version 3 quickly and easily collects and analyzes data from Isco 4100 Series Flow Loggers. Versatile Data Storage Flowlink is easy for beginners to use, yet provides all the power you need for advanced flow studies. Pull-down menus and pop-up windows allow you to quickly make selections. On-line help screens provide specific guidance for each step of the program. Each Flow Logger stores level, velocity, flow rate, rainfall and sample data. The memory can hold over 100,000...

Open the catalog to page 12

All Teledyne Isco catalogs and technical brochures