Catalog excerpts
Specifications 2150 Flow Module Size (HxWxD): Weight: Materials of construction: Enclosure (self-certified): Temperature Range: Power Required: Power Source: Typical Battery Life: Program Memory: 2.9 x 11.3 x 7.5 in (74 x 287 x 191 mm) 2.0 lb (0.9 kg) High-impact polystyrene, stainless steel NEMA 4X, 6P (IP68) -40° to 140° F (-40° to 60° C) operating and storage 12 VDC nominal (7.0 to 16.6 VDC), 100 mA typical, 1 mA standby Typically, an Isco 2191 Battery Module, containing 2 alkaline or 2 rechargeable lead-acid batteries. (Other power options are available; ask for details.) Using 15-minute data storage interval Energizer® Model 529 alkaline - 15 months Isco rechargeable lead-acid - 2.5 months Non-volatile programmable flash; can be updated using PC without opening enclosure; retains user program after updating. Built-in Conversions Flow Rate Conversions: Level-to-Area Conversions: Level-to-Flow Conversions: Total Flow Calculations: Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions. Channel Shapes - round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction; Data Points - Up to 50 level-area points. Most common weirs and flumes; Manning Formula; Data Points (up to 50 level-flow points); 2-term polynomial equation Up to 2 independent, net, positive or negative, based on either flow rate conversion Data Handling and Communications Data Storage: Non-volatile flash; retains stored data during program updates. Capacity 395,000 bytes (up to 79,000 readings, equal to over 270 days of level and velocity readings at 15-minute intervals, plus total flow and input voltage readings at 24-hour intervals) Level, velocity, flow rate 1, flow rate 2, total flow 1, Data Types: total flow 2, input voltage, temperature Storage Mode: Rollover; 5 bytes per reading. 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, Storage Interval: 4, 12, or 24 hours Storage rate variable based on level, velocity, flow rate, total flow, or input voltage Serial connection to PC or optional 2101 Field Wizard Data Retrieval: module; optional modules for spread spectrum radio; land-line or cellular modem; 1xRTT. Modbus and 4-20 mA analog available. Isco Flowlink for setup, data retrieval, editing, analysis, Software: and reporting Multi-module networking: Up to four 2100 Series Flow Modules, stacked and/or remotely connected. Max distance between modules 3300 ft (1000 m). Serial Communication 38,400 bps Speed: 2150 Area Velocity Sensor Size (HxWxD): Cable (Length x Diameter): 33 ft x 0.37 in (10 m x 9 mm) standard. Custom lengths available on request. 2.2 lbs (1 kg) Weight (including cable): Materials of construction: Operating Temperature: Sensor - Epoxy, chlorinated polyvinyl chloride (CPVC), stainless steel Cable - Polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC) 32° to 140° F (0° to 60° C) Level Measurement: Method - Submerged pressure transducer mounted in the flow stream Transducer Type - Differential linear integrated circuit pressure transducer Range (standard) 0.033 to 10 ft (0.010 to 3.05 m); (optional) up to 30 ft (9.15 m). Maximum Allowable Level 34 ft (10.5 m) Accuracy ±0.01 ft from 0.033 to 10 ft, (±0.003 m from 0.01 to 3.05 m,) Long-Term Stability ±0.023 ft/yr (±0.007 m/yr) Compensated Range 32° to 122°F (0° to 50°C) Velocity Measurement: Method - Doppler ultrasonic, frequency 500 kHz Typical Minimum Depth 0.08 ft (25 mm) Range -5 to +20 ft/s (-1.5 to +6.1 m/s) Accuracy (in water with uniform velocity profile, speed of sound = 4850 ft/s, for indicated velocity range) ±0.1 ft/s from -5 to 5 ft/s (±0.03 m/s from -1.5 to +1.5 m/s) ±2% of reading from 5 to 20 ft/s (1.5 to 6.1 m/s) Temperature Measurement: Accuracy ±3.6° F (±2° C) Isco 2150 Area Velocity Flow Module The 2150 Flow Module uses continuous wave Doppler technology to measure mean velocity. The sensor transmits a continuous ultrasonic wave, then measures the frequency shift of returned echoes reflected by air bubbles or particles in the flow. The 2150’s “smart” area velocity probe is built on digital electronics, so the analog level is digitized in the sensor itself to overcome electromagnetic interference. The probe is also factory-calibrated for 10-foot (3 meter) span at different temperatures. This built-in calibration eliminates drift in the level signal, providing long-term level stability that reduces recalibration frequency and completely eliminates span recalibration. Standard Features In field use, the 2150 is typically powered either by two alkaline, or Isco Rechargeable Lead-acid batteries, within a 2191 Battery Module. Highly efficient power management extends battery life up to 15 months at 15-minute data storage intervals. Other power options (including solar) are available. ♦ Replaceable high-capacity internal desiccant cartridge and hydrophobic filter protect sensor reference from water entry and internal moisture. Size (HxWxD): Weight (without batteries): High-impact polystyrene, stainless steel Enclosure (self certified): Two 6-volt Energizer Model 529* alkaline (25 Ahrs capacity) or Isco Rechargeable Lead-acid (5 Ahrs capacity) recommended. *Note – Energizer 529 ER does not give specified life. ♦ Portable and permanent-site AV flow monitoring for inflow and infiltration, capacity assessment, sewer overflow, and other sewer studies. 2150 Ordering Information Contact your Teledyne Isco representative for complete ordering details and information on other 2100 Series Modules. 2150 with AV sensor, 2191 Battery Module, and Handle 2150 Module with AV sensor (only) Isco Flowlink® 5 Software Energizer® Model 529 Alkaline Lantern Battery (2 required) Isco Rechargeable Lead-acid Battery (2 required) Charger for Lead-acid Batteries (holds 2 batteries) ♦ Measuring shallow flows in small pipes. Our low-profile area velocity sensor minimizes flow stream obstruction and senses velocity in flows down to 1 inch (25 mm) in depth. ♦ Rugged, submersible enclosure meets NEMA 4X, 6P (IP68) environmental specs. ♦ Chemically resistant epoxy-encapsulated sensor withstands abuse, resists oil and grease fouling, and eliminates the need for frequent cleaning. ♦ Pressure transducer vent system automatically compensates for atmospheric pressure changes to maintain accuracy. ♦ The quick-connect sensor can be easily removed and interchanged in the field without requiring recalibration. ♦ Up to four 2100 Series flow modules can be networked by stacking and/or extension cables. 4700 Superior Street Lincoln NE 68504 USA Tel: (402) 464-0231 USA and Canada: (800) 228-4373 Fax: (402) 465-3022 E-Mail: iscoinfo@teledyne.com Internet: www.teledyneisco.com Teledyne Isco reserves the right to change specifications without notice. © 2012 Teledyne Isco • L-2115 • rev 11/12 Above left: Additional modules can be added for redundant or multi-stream measuring (Isco 2110 Ultrasonic Module shown). Right: Optional mounting rings provide quick, secure sensor installation in round pipes from 6 to 80 inches (150 to 2000 mm).
Open the catalog to page 1All Teledyne Isco catalogs and technical brochures
-
CombiFlash Torrent
6 Pages
-
5800 Refrigerated Sampler
2 Pages
-
ReaXus 6010R
2 Pages
-
CombiFlash® NextGen 300+
3 Pages
-
CombiFlash® NextGen
3 Pages
-
CombiFlash® NextGen 300
3 Pages
-
Technical NOTE 33
2 Pages
-
accQpulse™ Velocity Profiler
2 Pages
-
ACCQPrep® HP125
4 Pages
-
RediSep Prep HPLC Columns
2 Pages
-
combiflash flash RF+ PurIon
2 Pages
-
combiflash EZ Prep
14 Pages
-
ISCO 4100 SERIES FLOW LOGGERS
16 Pages
-
2100 Series Flow Modules
16 Pages
-
4200 Series Flow Meters
20 Pages
-
L1150 AQ700
2 Pages
-
Retriever ® 500
2 Pages
-
Fraction Collectors
8 Pages
-
Foxy ® R1, Foxy ® R2
2 Pages
-
ELSD
4 Pages
-
Combiflash
2 Pages
-
CustomPumps Brochure 6th Ed
6 Pages
-
260D Syringe Pump
2 Pages
-
Syringe Pump Controller
2 Pages
-
2103ci Cell Phone Modem CDMA
2 Pages
-
CombiFlash Rf 150
2 Pages
-
65DM Syringe Pump
2 Pages
-
100DX Syringe Pump
2 Pages
-
D-Series Pumps
8 Pages
-
4501 Pump Station Monitor
2 Pages
-
676 Rainfall Logging System
2 Pages
-
Signature Flow Meter
2 Pages
-
Model 1000D Syringe Pump
2 Pages
-
Isco 674 Rain Gauge
2 Pages
-
3010 Ultrasonic Flow Transmitter
2 Pages
-
Isco 2102 Wireless Module
2 Pages
-
Avalanche Sampler datasheet
2 Pages
-
2110 Ultrasonic Module datasheet
4 Pages
-
2105 Interface Module
4 Pages
-
Power Products Brochure
8 Pages
-
65HP Syringe Pump
2 Pages
-
500SP Syringe Pump
2 Pages
-
500HV Syringe Pump
2 Pages
-
Rf Gold Large Columns Flyer
2 Pages
-
2009 Sampler Sourcebook
24 Pages
Archived catalogs
-
1000HL Syringe Pump
2 Pages
-
LaserFlow AV Sensor
4 Pages
-
RediSep Rf Gold Brochure
4 Pages