1. Catalogs
  2. Teledyne Isco
  3. accQpulse™ Velocity Profiler

accQpulse™ Velocity Profiler

accQpulse™ Velocity Profiler

accQpulse™ Velocity Profiler

Product catalog summary
Standard Features
  • Pulse Doppler velocity profiling technology.
  • Tri-redundant velocity sensors and a depth sensor in a compact housing.
  • Data quality verification with signal strength and correlation.
  • Chemically resistant polyurethane encapsulated sensor.
  • Rugged, submersible enclosure with IP 68 protection rating.
Options
  • Secondary pressure sensor for redundant level measurement.
  • Flow conditioning platform for shallow water sensor.
  • Sensor fairing for deep water channels with sediment or debris.
  • accQcomm digital/analog interface module for various interfaces.
  • Remote cell phone communication options.
  • QBADFM intrinsic safety barrier for hazardous area installation.
  • Flowlink data management software.
Applications

The accQpulseTM Velocity Profiler is suitable for various applications including wastewater systems, billing, combined sewer systems, wastewater treatment facilities, irrigation canals, industrial discharges, and stormwater conveyance.

Measurement Performance
  • Flow accuracy is 2.0% of reading.
  • Velocity measurement varies with depth, with specific ranges for shallow and deep water sensors.
  • Vertical profiling range and water level measurement are specified for both shallow and deep water sensors.
Physical Specifications
  • Operating temperature ranges from 23 to 113º F (-5 to 45º C).
  • Housing material is polyurethane.
  • Sensor signal cable is made of polyethylene jacket.
Principles of Operation

The sensor uses piezoelectric ceramic devices to emit acoustic pulses, measuring velocity through Doppler shift and depth with a vertically aimed device.

Data Management
  • Data types include flow, average velocity, depth, and more.
  • Data storage capacity is 4 MB with configurable data transfer rates.
  • Flowlink software assists with instrument configuration, diagnostics, and data management.
Hazardous Area Installation

The accQpulseTM is suitable for hazardous areas when used with the QBADFM intrinsic safety barrier.

Interface Module

The accQcommTM module provides various interfaces and is mountable, powered with 12 to 24 VDC.

See more

Catalog excerpts

accQpulse™ Velocity Profiler-1

accQpulse™ Deep Water Sensor accQpulse™ Shallow Water Sensor Measurement Performance Measurement Performance accQpulse™ Velocity Profiler Accurate flow measurement in shallow and deep water applications Profiler The accQpulse™ Velocity Profiler brings unparalleled precision and accuracy to flow rate measurement in many sizes of pipes and open channels. Its unique ability to measure velocity at multiple points makes it suitable for most applications including sites with non-uniform, rapidly changing, near zero, zero, or reverse flow conditions. These applications include: waste water collection systems, billing, combined sewer systems and outfalls, wastewater treatment facilities, irrigation canals, industrial discharges, and stormwater conveyance and outfalls. With sensor options for both shallow and deep water, the accQpulse™ Velocity Profiler is the only flexible pulse-doppler flow meter available. The shallow water sensor is used to measure flow in depths up to 40 inches (1m). The deep water sensor is used to measure flow in depths up to 16 feet (4.9 m). Standard Features • Pulse Doppler velocity profiling technology • Tri-redundant velocity sensors and a depth sensor combined in a single, compact housing • Data quality verification information (signal strength and correlation) • Chemically resistant polyurethane encapsulated sensor withstands abuse, resists oil and grease fouling, and eliminates the need for frequent cleaning • Rugged, submersible enclosure meets IP 68 protection rating TELEDYNE ISCO Everywhereyoulook™ 4700 Superior Street, Lincoln, NE 68504 USA • Tel: (402) 464-0231 • USA & Canada: (800) 228-4373 Fax: (402) 465-3022 • Email: [email protected] • http://teledyneisco.com Teledyne Isco is continually improving its products and reserves the right to change specifications without notice. ©2016 Teledyne Technologies Incorporated • Achieve accurate measurement By measuring velocity at multiple points, you can record accurate flow measurement. • Eliminate on-site calibration With detailed information on velocity at multiple points and advanced flow algorithms, there is no need for on-site calibration. • Rely on quality data information Verify that your data is accurate with diagnostic information and Flowlink software's data quality analysis. Options • Secondary pressure sensor for redundant level measurement • Flow conditioning platform for shallow water sensor • Sensor fairing for deep water channels where sediment or debris are present • accQcomm digital/analog interface module for 4-20 mA, RS-232/422, MODBUS, and Ethernet interface • Remote cell phone communication options • QBADFM intrinsic safety barrier for hazardous area installation classified as Class I, Div 1, Group C & D • Flowlink data management software TELEDYNE ISCOEver

 Open the catalog to page 1
accQpulse™ Velocity Profiler-2

accQpulse™ Velocity Profiler Principles of Operation Three piezoelectric ceramic devices in the sensor emit short acoustic pulses along narrow beams into the flow stream. Each beam points in a different direction to measure velocity. A fourth ceramic device is mounted in the center of the DEPTH Upward-looking ultrasonic measurement with no drift VELOCITY BINS Measure the velocity profil** sensor and aimed vertically to measure the depth. The acoustic signals are echoed back after contacting bubbles or particles. By measuring the difference in frequency between the emitted and returned signals (known...

 Open the catalog to page 2

All Teledyne Isco catalogs and technical brochures

  1. ReaXus 6010R

    2  Pages

  2. L1150 AQ700

    2  Pages

  3. ELSD

    4  Pages

  4. Combiflash

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.