1. Catalogs
  2. Teledyne Isco
  3. 5800 Refrigerated Sampler

5800 Refrigerated Sampler

5800 Refrigerated Sampler

5800 Refrigerated Sampler

Product catalog summary
Overview: The 5800 Refrigerated Sampler by Isco is designed for rigorous water monitoring tasks, featuring user-friendly controls and a slide-out bottle rack for easy access. It actively regulates and displays sample compartment temperature, logging a 24-hour summary for cooling confirmation.
Applications: Suitable for stationary sampling in municipal and industrial wastewater applications, the sampler ensures quality sample collection with superior pump performance and is designed to withstand extreme outdoor environments without requiring additional shelter.
Key Features:
  • Composite or sequential sampling capabilities.
  • Operational temperature range from -20 to 120°F (-29 to 49°C) without additional heaters.
  • Four digital alarm outputs and multiple flow meter input options.
  • Energy-efficient cooling with a powerful compressor.
  • Four stored programs and easy installation with lifting handles.
Sampling Modes: The sampler supports constant time-constant volume, constant time-variable volume, and variable time-constant volume modes.
Construction and Durability: The sampler features a tough, double-wall LLDPE cabinet for weather and corrosion resistance, with electro- and powder-coated stainless steel components for long life in corrosive environments.
Advanced Delivery System: Utilizes a peristaltic pump for sample delivery at EPA-recommended line velocities, with a pump revolution counter and liquid detection system ensuring volume accuracy.
Technical Specifications:
  • Size: 52 x 29 x 33 in (132 x 74 x 84 cm); Weight: 195 lb (88.5 kg).
  • Power: 115VAC, 60 Hz, or 230 VAC, 50 Hz.
  • Intake suction tubing length: 3 to 99 feet (0.9 to 30 m).
  • Maximum suction lift: 28 feet (8.5 m).
  • Typical repeatability and accuracy at lifts up to 25 ft.
Controller and Software: Features a NEMA 4X, 6 (IP67) rated enclosure, non-volatile ROM program memory, and supports various flow meter signal inputs. Programmable for up to 999 composite samples with automatic rinsing and diagnostic tests.
Ordering Information: Various bottle configurations are available, including options for different materials and sizes.
Contact Information: Teledyne Isco, Lincoln, NE, USA. Phone: (402) 464-0231, Email: [email protected], Website: http://teledyneisco.com
See more

Catalog excerpts

5800 Refrigerated Sampler-1

5800 Refrigerated Sampler Isco-tough and environmentally friendly The only choice for stationary sampling in both municipal and industrial wastewater applications The 5800 Refrigerated Sampler is Isco's answer to the rigorous demands of water monitoring, with user-friendly controls and task accommodating features. Along with easy control and on-site programmability, it also has a unique slide-out bottle rack to easily access sample containers. The controller actively regulates and displays the sample compartment temperature and logs a 24-hour summary to confirm proper sample cooling. The temperature record is downloadable using a basic utility program, such as Tera Term, or data can be viewed on the unit display. • Quality Sample Collection Superior pump performance results in repeatable sample volumes. • No Shelter Required Units can withstand extreme outdoor environments due to the quality design. The all-weather design is suitable for outdoor installation. • Low Maintenance Field replaceable parts reduce maintenance downtime. Standard System Features • Composite or sequential sampling • Operating range of -20 to 120°F (-29 to 49°C) - without additional heaters • Four digital alarm outputs • 4-20 mA, contact closure, and DC pulse flow meter input • Powerful compressor delivers energy-efficient, high-performance cooling • Four stored programs • Lifting handles for easy installation Sampling Modes The 5800 Sampler follows the Isco standard for weather and corrosion resistance. The tough, double-wall LLDPE cabinet protects against exposure in harsh environments. The well-insulated cabinet promotes temperature stability. Samples remain cool in hot and humid conditions, and a built in heater prevents freezing in cold conditions. Electro- and powder-coating protects the stainless steel components of the refrigeration system, ensuring long life and reliability in corrosive treatment plant conditions. Advanced delivery system The 5800 Sampler uses Isco's proven peristaltic pump to deliver samples at the EPA-recommended line velocity of at least 2 ft/s (0.6 m/s), and at head heights up to 25 feet (7.6 m). Sample volume accuracy is assured by the pump revolution counter and Isco's liquid detection system. TELEDYNE ISCO Everywhereyoulook" • Constant time - Constant volume • Constant time - Variable volume • Variable time - Constant volum

 Open the catalog to page 1
5800 Refrigerated Sampler-2

Controller Size (HxWxD) Enclosure rating Ordering Information TELEDYNE ISCO Everywhereyoulook" 4700 Superior Street, Lincoln, NE 68504 USA • Tel: (402) 464-0231 • USA & Canada: (800) 228-4373 Fax: (402) 465-3022 • Email: [email protected] • http://teledyneisco.com Teledyne Isco is continually improving its products and reserves the right to change specifications without notice. ©2016 Teledyne Technologies Incorporated

 Open the catalog to page 2

All Teledyne Isco catalogs and technical brochures

  1. ReaXus 6010R

    2  Pages

  2. L1150 AQ700

    2  Pages

  3. ELSD

    4  Pages

  4. Combiflash

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.