Product catalog summary
Overview: The document provides detailed information on Teledyne Hastings Instruments' high flow meters and controllers, specifically the HFC-D-308A/B Digital Flow Controller, HFM-D-306A/B Digital Flow Meter, and HFM-306 Analog Flow Meter. These instruments are designed for precise gas flow measurement and control, leveraging over 70 years of experience in gas flow instrumentation.
Features:
  • Flow ranges from 0-2500 slm to 0-10,000 slm for nitrogen.
  • Accuracy: HFC-D-308 and HFM-D-306 models offer ±(0.5% Rdg + 0.2% FS), while HFM-306 provides ±2% FS.
  • Operating pressure up to 300 PSI.
  • NIST traceable calibration and digital communication via RS232/RS485 for digital models.
Applications: These devices are suitable for alternate energy, fuel cell R&D, secondary calibration reference, specialty gas delivery, and custody transfer.
Benefits: Enhanced accuracy, superior linearity, and rapid settling time are highlighted as key advantages.
Description: The 300 Series transducer is a patented thermal-based flow sensor offering exceptional linear response and fast response time. The digital versions feature microprocessor-based circuitry for linearized flow response and enhanced accuracy. The HFC-D-308 models are digital mass flow controllers optimized for applications up to 10,000 SLM of air flow.
Specifications & Standards:
  • Compliance with European Pressure Equipment Directive (PED) 97/23/EC and various EN standards for safety and emissions.
  • Performance specifications include full-scale flow ranges, accuracy, repeatability, operating temperature, and pressure limits.
  • Electrical specifications cover voltage and power requirements for both 'A' and 'B' series models.
  • Physical specifications include weight and wetted materials such as 316 SS, 302 SS, Ni 200, Viton, Kalrez, and PTFE.
Selection Charts: Detailed selection charts for each model provide options for calibration type, output, working pressure, and fittings.
Accessories: Includes part numbers for flow transducer cables and power supplies, with options for different cable lengths and connectors.
See more

Catalog excerpts

high flow meters & controllers-1

www.teledyne-hi.com HFC-D-308A/B Digital Flow Controller HFM-D-306A/B Digital Flow Meter HFM-306 Analog Flow Meter FEATURES • Available Flow Ranges: 0-2500 slm to 0-10,000 slm (N2) • Operating Pressure to 300 PSI • NIST Traceable Calibration • RS232/RS485 (Digitals Only) • Totalized Flow (Digitals Only) APPLICATIONS • Alternate Energy • Fuel Cell R&D • Secondary Calibration Reference • Specialty Gas Delivery • Custody Transfer BENEFITS • Enhanced Accuracy • Superior Linearity • Rapid Settling Time HFM-306 Analog Flow Meter TELEDYNE HASTINGS INSTRUMENTSEverywhereyoulook&qu

 Open the catalog to page 1
high flow meters & controllers-2

Teledyne Hastings Instruments products represent over 70 years of experience in the design and manufacture of gas flow instrumentation. The high flow meters and controllers featured in this document are based on the 300 Series line of flow sensors. The 300 Series transducer is a patented thermal based flow sensor. This sensor is designed to provide exceptional linear response to changing flow rates. In addition, the electronics associated with the sensor are precisely tuned to give fast response time. The flow transducer is combined with a laminar flow element to configure the flow meter for...

 Open the catalog to page 2
high flow meters & controllers-3

Flexible 15-Pin connector for analog I/O LEDs (2) provide status and flow conditions Easily configurable digital communications LEDs (2) provide status and flow conditions

 Open the catalog to page 3
high flow meters & controllers-4

Performance Full Scale Flow Ranges (N2) Microprocessor-based Enhanced Accuracy and Digital Features Accuracy Repeatability Operating Temperature Warm up time Temperature Coefficient of Zero Temperature Coefficient of Span Operating Pressure -Maximum Electrical Voltage Power “A” Series Power “B” Series Physical Weight (approx.) Wetted Materials 2,500 to 10,000 SLM YES ± (0.5% Rdg + 0.2% FS) ± 0.15% of FS -20° - 70°C 30 min optimum accuracy 2 min for ± 5% of full scale Auto-zero when Valve is Closed Maximum ±0.1%(Rdg)/°C (-20—70°C) 300 psig 11 -36 VDC (±12, ±15 acceptable) 15 VDC min. for 0-20...

 Open the catalog to page 4
high flow meters & controllers-8

Selection Chart HFM-D-306A & HFC-D-308A Model Number Circuit Board Circuit Board 01 Pinout H (Std) 01 02 03 04 Output 0-5 Volt (Std) 0-10 Volt 4-20 mA 0-20 mA Fittings 01 1” Compression 02 1 1/2” Compression 03 2” Compression (Std) Seals 01 Viton (Std) 04 Buna-N 02 Kalrez (Meter Only) 03 Neoprene (Meter Only) Calibration Type 1 NIST Traceable Calibration Report (Std) 2 NIST Traceable Calibration Reports 3 NIST Traceable Calibration Reports 4 NIST Traceable Calibration Reports 5 NIST Traceable Calibration Reports 6 NIST Traceable Calibration Reports 7 NIST Traceable Calibration Reports 8 NIST...

 Open the catalog to page 8
high flow meters & controllers-9

www.teledyne-hi.comSelection Chart HFM-D-306B & HFC-D-308B Model Number

 Open the catalog to page 9
high flow meters & controllers-11

THCD-100 Single Channel Power Supply Meter THCD-100 Includes brackets, connectors, and backshells 24 VDC Switching Power Supply 12-01-169 For use with “B' Series or THCD-100 (Please specify AC Input Clip) Flow Transducer Cable Part Numbers: Connect Hastings Power Supply to “A” Series Flow Meters & Controllers AF-4-AM World Wide Web: http://www.teledyne-hl.com E-mail: [email protected] 804 Newcombe Ave. Hampton, VA 23661 “A” Series—Serial Communication Cable: CB-RS232-RJ12 RS232 Cable (9-Pin “D” Female to RJ12) “B” Series—Serial Communication Cable: CB-RS232-TRRS RS232 Cable...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.