HFM-HFC - 1

FEATURES 301/303 Range 0 - 25 slm to 0-1000 slm 305/307 Range 0-1000 slm to 0-2500 slm (N2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) Touchscreen Display/Control Option 0-5 VDC, 0-10 VDC, 0-20 mA or 4-20 mA I/O RS232 / RS485 Typical Settling Time: • HFM-D-301/305 < 1 second Self-diagnostic Status LEDs Auto-Zero (Controllers Only) Totalizer Large Diameter Sensor Tube (low dP) Low Wetted Surface Area Operating Pressures to 500 psi or higher NIST Traceable Calibration APPLICATIONS Leak Testing HFC-D-303A Mass Flow Controller Optional Touchscreen Display • High Purity Gas Delivery • Heat Treat • Gas Blending • Secondary Calibration Reference • Fuel Cell R&D • Environmental Monitoring BENEFITS • High Accuracy • Fast Metering Response • Superior Linearity • Rapid Controller Settling Time • Digital Extended Range Data Logging Software

Open the catalog to page 1
HFM-HFC - 2

Description The Digital 300 Series of thermal mass flow meters and controllers from Teledyne are designed to accurately measure mass flow without corrections or compensations for gas pressure and temperature. They are accurate to better than ±(0.5% of reading + 0.2% of full scale) for full scale flow rates from 0-5 sccm to 0-10,000 slm. The Digital 300 Series uses a thermal-based mass flow sensor. This sensor is designed to provide exceptional linear response to changing flow rates. In addition, the electronics associated with each sensor are precisely tuned to give fast response times. The...

Open the catalog to page 2
HFM-HFC - 3

Flexible 15-Pin connector for analog I/O LEDs (2) provide status and flow conditions Easily configurable digital communications LEDs (2) provide status and flow conditions

Open the catalog to page 3
HFM-HFC - 4

Digital 300 Series Flow Sensor The Digital 300 Series is built using a patented (Patent #6,125,695) flow sensor. The sensor's excellent linearity, in turn, leads to improved accuracy. Flow calibrations are typically performed in N2 or air. The output can then be scaled for use in other gases (see graph to the right). The 300 Series excellent linearity allows the linearity to be retained when switching from the calibration gas to the process gas. The patented sensor contains fast electronic circuitry. This is critical when the flow meter is coupled with a proportional control valve to create...

Open the catalog to page 4
HFM-HFC - 5

Outline Drawings HFM-D-301 A & B Series

Open the catalog to page 5
HFM-HFC - 6

r Outline Drawings HFC-D-303 A & B Series L

Open the catalog to page 6
HFM-HFC - 7

Outline Drawings HFM-D-305 A & B Series

Open the catalog to page 7
HFM-HFC - 8

Outline Drawings HFC-D-307 A & B Series

Open the catalog to page 8
HFM-HFC - 9

www.teledyne-hi.com Selection Chart - HFM-D-301A & HFC-D-303A For Models HFM-D-301A HFC-D-303A Circuit Board Circuit Board Small Base Fittings Large Base Fittings |Working Pressure Calibration Options Range Information for all Instruments Each calibration will require the following information: Range Flow Units Gas For the HFC Instruments also Upstream Pressure (maximum & minimum) Downstream Pressure (maximum cS minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used...

Open the catalog to page 9
HFM-HFC - 10

www.teledyne-hi.com Selection Chart HFM-D-301B & HFC-D-303B For Models HFM-D-301B HFC-D-303B Small Base Fittings Large Base Fittings Working Pressure Calibration Records Calibration Type Range Information for all Instruments Each calibration will require the following information: Range Flow Units Gas For the HFC Instruments also Upstream Pressure (maximum & minimum) Downstream Pressure (maximum & minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used when other...

Open the catalog to page 10
HFM-HFC - 11

www.teledyne-hi.com Selection Chart - HFM-D-305A & HFC-D-307A For Models HFM-D-305A HFC-D-307A Circuit Board Circuit Board Working Pressure Calibration Type Range Information for all Instruments Each calibration will require the following information: Range Flow Units Gas For the HFC Instruments also Upstream Pressure (maximum & minimum) Downstream Pressure (maximum & minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used when other values are not specified

Open the catalog to page 11
HFM-HFC - 12

www.teledyne-hi.comSelection Chart - HFM-D-305B & HFC-D-307B Output

Open the catalog to page 12
HFM-HFC - 13

THCD-100 Single Channel Power Supply Meter THCD-100 Includes brackets, connectors, and backshells 24 VDC Switching Power Supply 12-01-169 For use with “B' Series or THCD-100 (Please specify AC Input Clip) Flow Transducer Cable Part Numbers: Connect Hastings Power Supply to “A” Series Flow Meters & Controllers AF-4-AM (757)723-6531 www.teledyne-hi.com hastings_instruments@teledyne. com 804 Newcombe Avenue Hampton, VA 23669 “A” Series—Serial Communication Cable: CB-RS232-RJ12 “B” Series—Serial Communication Cable: CB-RS232-TRRS RS232 Cable (9-Pin “D” Female to Male TRRS Jack 8 Ft TELEDYNE...

Open the catalog to page 13

All Teledyne Hastings Instruments catalogs and technical brochures

  1. DAVC

    5 Pages

  2. HPM 4/5/6

    4 Pages

  3. Gauge Tubes

    10 Pages

  4. DCVT & DVT

    6 Pages

  5. HFM-200 LFE

    5 Pages

  6. HFM-200-LFE

    5 Pages

  7. Digital VT

    6 Pages

  8. HFM-306

    4 Pages

Archived catalogs

  1. NALL SERIES

    2 Pages

  2. PowerPod-400

    4 Pages

  3. THCD—100

    6 Pages

  4. THCD-400

    5 Pages

  5. THCD—100

    6 Pages

  6. THCD-100​

    6 Pages

  7. HPM-760S

    4 Pages

  8. Products

    6 Pages

  9. THCD -100

    6 Pages

  10. THPS-400

    4 Pages

  11. 760 Plus

    2 Pages