Mass Flow Meter Mass Flow Controller Mass Flow Meter Mass Flow Controller Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) Touchscreen Display/Control Option 0-5 VDC, 0-10 VDC, 0-20 mA or 4-20 mA I/O RS232 / RS485 Typical Settling Time: HFM-D-301/305 < 1 second HFC-D-303/307 1 –2 seconds Self-diagnostic Status LEDs Auto-Zero (Controllers Only) Totalizer Large Diameter Sensor Tube (low dP) Low Wetted Surface Area Operating Pressures to 500 psi or higher NIST Traceable Calibration Leak Testing High Purity Gas Delivery Heat Treat Gas Blending Secondary Calibration Reference Fuel Cell R&D Environmental Monitoring High Accuracy Fast Metering Response Superior Linearity Rapid Controller Settling Time Digital Extended Range Mass Flow Meters & Controllers HFC-D-303A Mass Flow Control
Open the catalog to page 1Description The Digital 300 Series of thermal mass flow meters and controllers from Teledyne are designed to accurately measure mass flow without corrections or compensations for gas pressure and temperature. They are accurate to better than ±(0.5% of reading + 0.2% of full scale) for full scale flow rates from 0-5 sccm to 0-10,000 slm. The Digital 300 Series uses a thermal-based mass flow sensor. This sensor is designed to provide exceptional linear response to changing flow rates. In addition, the electronics associated with each sensor are precisely tuned to give fast response times. The...
Open the catalog to page 2Flexible 15-Pin connector for analog I/O LEDs (2) provide status and flow conditions Easily configurable digital communications LEDs (2) provide status and flow conditions
Open the catalog to page 3www.teledyne-hi.com Digital 300 Series Flow Sensor The Digital 300 Series is built using a patented (Patent #6,125,695) flow sensor. The sensor's excellent linearity, in turn, leads to improved accuracy. Flow calibrations are typically performed in N2 or air. The output can then be scaled for use in other gases (see graph to the right). The 300 Series excellent linearity allows the linearity to be retained when switching from the calibration gas to the process gas. The patented sensor contains fast electronic circuitry. This is critical when the flow meter is coupled with a proportional...
Open the catalog to page 4Outline Drawings HFM-D-301 A & B Series
Open the catalog to page 5Outline Drawings HFC-D-303 A & B Series
Open the catalog to page 6Outline Drawings HFM-D-305 A & B Series
Open the catalog to page 7Outline Drawings HFC-D-307 A & B Series
Open the catalog to page 8Range Information Each calibration will require Flow Units Upstream Pressure (maximum & minimum) Downstream Pressure (maximum & minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used when other values
Open the catalog to page 9Calibration Type Touchscreen Display Range Information Each calibration will require Flow Units Upstream Pressure (maximum & minimum) Downstream Pressure (maximum & minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used when other values
Open the catalog to page 10Range Information Each calibration will require Flow Units Upstream Pressure (maximum & minimum) Downstream Pressure (maximum & minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used when other values
Open the catalog to page 11Range Information Each calibration will require Flow Units Upstream Pressure (maximum & minimum} Downstream Pressure (maximum & minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used when other values
Open the catalog to page 12Power Supplies & Accessories THCD-100 Single Channel Power Supply Meter THCD-100 Includes brackets, connectors, and backshells 24 VDC Switching Power Supply 12-01-169 For use with “B’ Series or THCD-100 (Please specify AC Input Clip) Flow Transducer Cable Part Numbers: Connect Hastings Power Supply to “A” Series Flow Meters & Controllers AF-4-AM “A” Series—Serial Communication Cable: CB-RS232-RJ12 “B” Series—Serial Communication Cable: CB-RS232-TRRS (757) 723-6531 www.teledyne-hi.com hastings_instruments@teledyne.com 804 Newcombe Avenue Hampton, VA 23669 RS232 Cable (9-Pin “D” Female to...
Open the catalog to page 13All Teledyne Hastings Instruments catalogs and technical brochures
-
Service Overview
4 Pages
-
high flow meters & controllers
11 Pages
-
THCD-101 Product Bulletin
6 Pages
-
Thermocouple Gauge Tubes
10 Pages
-
VT & CVT Series
7 Pages
-
HFM-HFC
13 Pages
-
HFM-201/HFC-203
7 Pages
-
DAVC
5 Pages
-
HPM 4/5/6
4 Pages
-
DIGITAL 300 SERIES
8 Pages
-
Gauge Tubes
10 Pages
-
Rugedized Vacuum Gauge Tube
1 Pages
-
REFERENCE TUBES
2 Pages
-
DCVT & DVT
6 Pages
-
HFM-305 / HFC-307
4 Pages
-
HFM-301 / HFC-303
4 Pages
-
HFM-205 / HFC-207
5 Pages
-
HFM-200 LFE
5 Pages
-
HFM-301/305/306
24 Pages
-
HFM-200-LFE
5 Pages
-
Digital VT
6 Pages
-
HFM-D-301, 303, 305, 307
6 Pages
-
HFM-D-300/HFC-D-302
4 Pages
-
HFM-306
4 Pages
-
HFM-305/HFC-307
4 Pages
-
HFM-301/HFC-303
4 Pages
-
HFM-300/HFC-302
4 Pages
-
HFM-210/HFC-212
4 Pages
-
HFM-200/HFC-202
4 Pages
Archived catalogs
-
NALL SERIES
2 Pages
-
PowerPod-400
4 Pages
-
THCD—100
6 Pages
-
THCD-400
5 Pages
-
THCD—100
6 Pages
-
THCD-100
6 Pages
-
HPM-760S
4 Pages
-
Installation Accessories
2 Pages
-
Products
6 Pages
-
Flow Service Plan
1 Pages
-
THPS-400 / PowerPod 400
4 Pages
-
IGE-3000
2 Pages
-
Nall Mass Flow Meters
2 Pages
-
THCD -100
6 Pages
-
THPS-400
4 Pages
-
760 Plus
2 Pages
-
THI Product Overview
6 Pages
-
HFM-E-200/HFC-E-202
4 Pages