Group: Teledyne Technologies Incorporated
Catalog excerpts
TELEDYNE HASTINGS INSTRUMENTSEverywhereyoulook-” HFC-D-308A/B Digital Flow Controller HFM-D-306A/B Digital Flow Meter {/) HFM-306 Analog Flow Meter ^ • Available Flow Ranges: » Operating Pressure to 300 PSI IP-67 Version Available (“A” Series) NIST Traceable Calibration Touchscreen Display Option (“B” Series) RS232/RS485 (Digitals Only) USB (“B” Series) Totalized Flow (Digitals Only) odCO HFC-D-308A Mass Flow Controller APPLICATIONS • Alternate Energy • Fuel Cell R&D • Secondary Calibration Reference • Specialty Gas Delivery • Custody Transfer BENEFITS • High Accuracy • Fast Metering Response • Superior Linearity • Rapid Controller Settling Time • Digital Extended Range HFM - 306 Analog Flow Meter TELEDYNE HASTINGS INSTRUMENTS Eve
Open the catalog to page 1Teledyne Hastings Instruments products represent over 70 years of experience in the design and manufacture of gas flow instrumentation. The high flow meters and controllers featured in this document are based on the 300 Series line of flow sensors. The 300 Series transducer is a patented thermal based flow sensor. This sensor is designed to provide exceptional linear response to changing flow rates. In addition, the electronics associated with the sensor are precisely tuned to give fast response time. The flow transducer is combined with a laminar flow element to configure the flow meter...
Open the catalog to page 2Performance Full Scale Flow Ranges (N2) Microprocessor-based Enhanced Accuracy and Digital Features Accuracy Repeatability Operating Temperature Warm up time Temperature Coefficient of Zero Temperature Coefficient of Span Operating Pressure -Maximum Electrical Voltage Power “A” Series Power “B” Series Physical Weight (approx.) Wetted Materials 2,500 to 10,000 SLM YES ± (0.5% Rdg + 0.2% FS) ±0.15% of FS -20° - 70°C 30 min optimum accuracy 2 min for ± 5% of full scale Auto-zero when Valve is Closed Maximum ±0.1%(Rdg)/°C (-20—70°C) 300 psig 11 -36 VDC (±12, ±15 acceptable) 15 VDC min. for 0-20...
Open the catalog to page 4Outline Drawing HFM-D-306A (with IP-67)
Open the catalog to page 7Outline Drawing HFC-D-308A (with IP-67)
Open the catalog to page 8Selection Chart HFM-D-306A & HFC-D-308A Model Number Circuit Board Circuit Board 01 Pinout H (Std) 02 IP-67 Enclosure Output 0-5 Volt (Std) 0-10 Volt 4-20 mA 0-20 mA Fittings 01 1” Compression 02 1 1/2” Compression 03 2” Compression (Std) Seals 01 Viton (Std) 04 Buna-N 02 Kalrez (Meter Only) 03 Neoprene (Meter Only) Calibration Type 1 NIST Traceable Calibration Report (Std) 2 NIST Traceable Calibration Reports 3 NIST Traceable Calibration Reports 4 NIST Traceable Calibration Reports 5 NIST Traceable Calibration Reports 6 NIST Traceable Calibration Reports 7 NIST Traceable Calibration...
Open the catalog to page 10Model Number
Open the catalog to page 11Model Number Range Information for all Instruments Each calibration will require the following information: Range Flow Units Gas For the HFC Instruments also Upstream Pressure (maximum & minimum):': Downstream Pressure (maximum & minimum) Does the downstream pressure change with flowrate? Y/N For volumetric units the standard temperature and pressure of the unit is also required 0°C & 760 Torr will be used when other values are not specified
Open the catalog to page 12THCD-100 Single Channel Power Supply Meter THCD-100 Includes brackets, connectors, and backshells 24 VDC Switching Power Supply 12-01-169 For use with “B' Series or THCD-100 (Please specify AC Input Clip) Connects Hastings Power Supply (15-pin) to 300 “A" Series (15-pin) Other lengths available Connects Hastings Power Supply (15-pin) to 300 “B” Series (9-pin) Other lengths available CB-12PCF-8-LDS (BareLeads) CB-12PCF-8-AM (Hastings ftwerSupply) Other lengths available “B” Series—Serial Communication Cable CB-RS232-TRRS RS232 Cable (9-pin “D” Female to Male TRRS) 6’ Cable (~1.8m) “A”...
Open the catalog to page 13All Teledyne Hastings Instruments catalogs and technical brochures
-
Service Overview
4 Pages
-
high flow meters & controllers
11 Pages
-
THCD-101 Product Bulletin
6 Pages
-
Thermocouple Gauge Tubes
10 Pages
-
VT & CVT Series
7 Pages
-
HFM-HFC
13 Pages
-
HFM-201/HFC-203
7 Pages
-
DAVC
5 Pages
-
HPM 4/5/6
4 Pages
-
DIGITAL 300 SERIES
8 Pages
-
Gauge Tubes
10 Pages
-
Rugedized Vacuum Gauge Tube
1 Pages
-
REFERENCE TUBES
2 Pages
-
DCVT & DVT
6 Pages
-
HFM-305 / HFC-307
4 Pages
-
HFM-301 / HFC-303
4 Pages
-
HFM-205 / HFC-207
5 Pages
-
HFM-200 LFE
5 Pages
-
HFM-301/305/306
24 Pages
-
HFM-200-LFE
5 Pages
-
Digital VT
6 Pages
-
HFM-D-301, 303, 305, 307
6 Pages
-
HFM-D-300/HFC-D-302
4 Pages
-
HFM-306
4 Pages
-
HFM-305/HFC-307
4 Pages
-
HFM-301/HFC-303
4 Pages
-
HFM-300/HFC-302
4 Pages
-
HFM-210/HFC-212
4 Pages
-
HFM-200/HFC-202
4 Pages
Archived catalogs
-
NALL SERIES
2 Pages
-
PowerPod-400
4 Pages
-
THCD—100
6 Pages
-
THCD-400
5 Pages
-
THCD—100
6 Pages
-
THCD-100
6 Pages
-
HPM-760S
4 Pages
-
Installation Accessories
2 Pages
-
Products
6 Pages
-
Flow Service Plan
1 Pages
-
THPS-400 / PowerPod 400
4 Pages
-
HFM-305A / HFC-307A
13 Pages
-
IGE-3000
2 Pages
-
Nall Mass Flow Meters
2 Pages
-
THCD -100
6 Pages
-
THPS-400
4 Pages
-
760 Plus
2 Pages
-
THI Product Overview
6 Pages
-
HFM-E-200/HFC-E-202
4 Pages