Catalog excerpts

A Teledyne Technologies Company Better Energy Solutions. What Listening Generates. On-site, on-demand ultrapure gas generationDelivery Options up to 56 nm3/hr (2119 scfh) H2 & 28 nm3/hr (1059 scfh) O2 Complete hydrogen plant design including instrumentation, compression and storage solutions TITAN ٙ APPLICATIONS Semiconductor fabrication, electronics fabrication, optical fiber production, chemical feedstock, float glass processing, metals processing, power generator cooling, and fuel cell testing > Reliable, compact designs for testing single cells to multiple cell stacks up to 12kW Options available for testing PEM, SOFC, and DMFC Testing services performed by leading fuel cell test engineers utilizing MEDUSAή Fuel Cell Test Stations and TITAN Hydrogen Generators MEDUSA ٮ APPLICATIONS Fuel cell (single to multiple cell stacks) component research and development, long term durability, and quality testing, including high temperature MEA testing > Highly reliable thermoelectric and PEM fuel cell power systems for any remote environmentEngineering services utilizing our core competencies in materials science, electrochemistry, and systems engineering to meet unique program applicationsA robust line of fuel cell stacks specially designed for reliability and long life using hydrogen/oxygen as the fuel/oxidantFlexible choices in voltage, power, pressure, and fuel ADVANCED POWER SYSTEMS APPLICATIONS Spacecraft, space habitat, unmanned aircraft/airships, manned/unmanned underwater vehicles and other remote sites > PERRY NG APPLICATIONS Space power, unmanned vehicle, APUs, and stationary power > MEDUSA is a TELEDYNE ENERGY SYSTEMS, INC. Registered Trademark for its Fuel Cell Test Station үۙ TELEDYNE ENERGY SYSTEMS, INC. 2005. All rights reservedTITAN is a TELEDYNE ENERGY SYSTEMS, INC. Trademark for its Hydrogen Gas Generators TELEDYNE ENERGY SYSTEMS, INC. 2005. All rights reserved ES-1041(11/2005) size="-2">
Open the catalog to page 1
Ultrapure Pressurized Gas Simplified Installation High Quality Standards Proven Reliability Safe, Automatic Operation On Demand Gas Delivery Ultrapure Gas Pressurized, on-demand, ultrapure (99.9998%) hydrogen delivery with no additional purification required Pressurized ultapure oxygen (99.999%), free of hydrocarbons and other atmospheric contaminants with auxiliary purifier Ease of Installation for Classified Areas All process controls and gas handling provisions in one cabinet, requiring much less floor space than comparable low pressure systems Cabinet suitable for installation and...
Open the catalog to page 3
Ultrapure Pressurized Gas Simplified Installation > High Quality Standards > Proven Reliability Safe, Automatic Operation > Picture Tube Fabrication Electronics Fabrication Optical Fiber Production Metals Processing > Fuel Cell Testing Performance Pressure 4.9 kg/cm2 (70 psig) max. Flow 25-100 SLM, 53-212 scfh, 1.4 to 5.6 nm > 3 /hr Purity 99.999% Standards Hazardous Location ClassificationClass I, Division 2, Group B Control Method Programmable Logic Interface Interface Touch Screen Facility Requirements Electric 120 VAC, 50/60 Hz, Single Phase, 30A ServiceCooling Water Flow 7.6 lpm (2...
Open the catalog to page 5
Ultrapure Gas Pressurized, on-demand, ultrapure (99.9998%) hydrogen delivery with no additional purification required Pressurized ultrapure oxygen (99.999%), free of hydrocarbons and other atmospheric contaminants with optional purifier package Ease of Installation for Classified Areas All process controls and gas handling provisions in one unit, requiring much less floor space than comparable systems System suitable for installation and operation in Class I, Division 2, Group B classified area per ANSI/NFPA 70, Article 500 Separate power supply enclosure with integrated rectifier for...
Open the catalog to page 6
RD-125W RD-500W RD-1000W Fuel Cell Test Systems for PEM, SOFC, and DMFC Fuel Cells (Single to Multiple Cells) up to 1000W Reliable systems for maximum run-time efficiencyAccurate Dew Point Temperature Control Scribner Associates Software and Electronic Loads Pre-Assembled/Factory Tested for Plug & Play Designed for Safe, Long-Term Unattended Testing Worldwide Service and Support Knowledge equals Power΅. We offer the most reliable fuel cell test stations in the industry, with customers performing uninterrupted durability tests for months at a time. Our continuous use of the equipment and...
Open the catalog to page 8
Accessories to provide additional capability to the MEDUSA ή RD and HTRD Fuel Cell Test Station Series to meet your specific testing requirements Plug and Play operation with the MEDUSA RD and HTRD Systems Control using the FuelCell Ι for Windows Software MEDUSA AR > Automatic Back Pressure Regulation System Automatic Back Pressure Control 0 to 30 psig or 2 to 100 psig MEDUSAή RS > Reformate Simulator Up to 5 mass flow controllers available to create custom reformate mixtures MEDUSA AC > Active Cooling Module MEDUSAή CH > Coolant flow control for small stacks or large active area cells,...
Open the catalog to page 10
PERFORMANCE Automatic Back Pressure Control 0 to 30 psig or 2 to 100 psig Accuracy > + ? 0.35% FS SOFTWARE CONTROL > Pressure Set Point Anode and Cathode Pressure Differential Maximum difference between anode & cathode SAFETY FEATURES Pressure Bypass Power failure opens bypass for system depressurization FACILITY REQUIREMENTS Electric 120 VAC Single Phase, 60 Hz, 15A MEDUSA > RD Compatible RS-485 Signal Connection from MEDUSA > ή RD Nitrogen Supply Minimum 35 psig supply pressure Ventilation Anode and cathode vents > Reformate Constituent Gases 5 user customizable high accuracy mass flow...
Open the catalog to page 11
Accurate Dew Point Temperature ControlUser Friendly MEDUSA StackProٙ Software Pre-Assembled/Factory Tested for Plug & Play Rolling cart with quick disconnect fittings enables stack portabilityRequires less floor space than comparable systems Experience Built on a foundation of over 30 years of experience in electrochemical systemsCustomer support and field service technicians who are knowledgeable and experienced in fuel cell testing to ensure your timely success Quality and Reliability for Safe Operation Unparalleled dew point control, factory certified using NIST traceable chilled mirror...