Overview: The Xineos family of CMOS X-ray Flat Detectors by Teledyne DALSA offers high-speed, low-dose imaging at full resolution. These detectors utilize proprietary Rad-Hard CMOS Active Pixels, surpassing the performance of traditional Image Intensified detectors while maintaining the benefits of flat panel detectors. They set new industry standards in DQE, low power dissipation, and radiation lifetime.
Key Features:
  • Monolithic Crystalline Silicon and CMOS Active Pixel Design.
  • 198 µm pixel pitch with best-in-class DQE at all doses.
  • High MTF, long X-ray lifetime, low readout noise, image lag, and dark current.
  • Frame rates up to 30 fps at full resolution and 200 fps in Panoramic Mode.
  • GigE data interface and CsI scintillator.
Specifications:
  • CMOS Pixel Array: 1548 x 1548 with a pixel size of 198 µm x 198 µm.
  • X-ray Sensitive Area: 307 mm x 302 mm.
  • Energy Range: 40 kV to 120 kV.
  • Saturation Dose Per Frame: 1 mR in Dynamic Range Mode, 100 µR in Low Dose Mode.
  • Frame Rates: 30 fps in Pulsed and Continuous X-ray Modes, >200 fps in Panoramic Mode.
  • Bit Depth: 14 bits with a typical dynamic range of 69 dB in Low Dose Mode and 75 dB in Dynamic Range Mode.
  • DQE: 75% @ 50 µR, 65% @ 0.1 µR (CsI Scintillator).
  • MTF: 60% @ 1lp/mm (CsI Scintillator).
  • Image Lag: <0.1%.
  • Non-Linearity: <1.5%.
  • Data and Control Interface: GigE Vision using CAT6 Cable.
  • Power Supply: +12 VDC with power consumption of 16 W in readout, 10 W in standby, and 5 W in hibernate.
  • Lifetime X-ray Dose: 1 MegaRad.
  • Mass: 16 kg.
Applications: The Xineos-3131 is suitable for dental, industrial, and scientific X-ray purposes, including LFOV Dental CBCT, Frame Based Panoramic Imaging, Industrial CBCT, Scientific X-ray Crystallography, and Veterinary Imaging.
Connectivity: The detector includes connectors for a 12 V power supply, Trigger I/O, GigE Data and Control Interface, and a 5 V Peripheral Power Supply.
Product Family: The Xineos family includes the Xineos-3131, Xineos-1313, and Xineos-2121, designed to replace 12 inch, 6 inch, and 9 inch II cameras respectively.
See more

Catalog excerpts

Xineos 3131-1

CMOS Flat Detector for Dynamic X-Ray Imaging Xineos CMOS X-ray Flat Detectors. High Speed, Low Dose Imaging at Full Resolution. Utilizing Teledyne DALSA’s proprietary Rad-Hard CMOS Active Pixels, the Xineos family of CMOS X-ray Flat Detectors is the industry’s first to exceed the low dose performance of Image Intensified detectors whilst providing all the benefits of flat panel detectors. This performance is provided at full speed and full resolution while setting new industry benchmarks in DQE, low power dissipation and radiation lifetime. The Xineos-3131 is available for Dental, Industrial and Scientific X-ray purposes. These Dynamic X-ray applications benefit from 30 fps frame rates at full resolution combined with exceptionally low noise and elimination of image artifacts. Region of Interest (ROI) modes can be used to capture small regions of interest at 200 fps or faster. Key Features • Monolithic Crystaline Silicon Specifications (Typical Values @ RQA5) • CMOS Active Pixel Design • 198 µm pixel pitch • Best in class DQE at all doses • High MTF • Long X-ray Lifetime • Low readout noise • Low image lag • Low dark current • Up to 30 fps at full resolution • 200 fps or more in Panoramic Mode • GigE data interface • CsI scintillator Typical Applications • LFOV Dental CBCT • Frame Based Panoramic Imaging • Industrial CBCT • Scientific X-ray Crystallography • Veterinary Imaging CMOS Pixel Array Pixel Size X-ray Sensitive Area Energy Range Saturation Dose Per Frame Frame Rates Bit Depth Typical Dynamic Range DQE (@ 0lp/mm, RQA5) MTF (@ 1lp/mm, RQA5) Image Lag Non-Linearity Data and Control Interface External X-ray Pulse Sync Power Supply Detector Power Consumption Lifetime X-ray Dose Mass 1548 x 1548 198 µm x 198 µm 307 mm x 302 mm 40 kV to 120 kV 1 mR in Dynamic Range Mode 100 µR in Low Dose Mode 30 fps Pulsed X-ray Mode full resolution, 15 ms exposure window 30 fps Continuous X-ray Mode 100% continuous integration time >200 fps Panoramic Mode 100% continuous integration time 14 bits 69 dB in Low Dose Mode 75 dB in Dynamic Range Mode 75% @ 50 µR, 65% @ 0.1 µR (CsI Scintillator) 60% (CsI Scintillator) <0.1% (Silicon Performance) <1.5% GigE Vision (using CAT6 Cable)* TTL Master and Slave configurations +12 VDC Readout 16 W, Standby 10 W, Hibernate 5 W 1 MegaRad 16 kg

 Open the catalog to page 1
Xineos 3131-2

CMOS Flat Detector for Dynamic X-RaylmagrT^^ Large format detector Single tile detector The Complete Xineos Family After 50 years of Image Intensifier (II) dominance in low dose X-ray applications, Teledyne DALSA has introduced a complete family of CMOS X-ray Flat Detectors. Xineos sets new benchmarks never before achieved by II cameras or flat detectors. X-Ray Detector DQE(O) @ RQA5 with following connectors: • 12V Power Supply to Detector Connector type: Male 9 pin D-sub Connector type: Lemo EXG.1 B.304.HLN • GigE Data and Control Interface Connector type: HALO HFJ11-1G16E-L12RL • 5 V Peripheral...

 Open the catalog to page 2

Archived catalogs

  1. Sapera APF

    4  Pages

  2. Piranha HS 8k

    2  Pages

  3. 1M30

    2  Pages

  4. BOA Pro

    2  Pages

  5. Icon

    4  Pages

  6. Pantera 22M04

    2  Pages

  7. FT50M

    2  Pages

  8. IA-DJ

    17  Pages

  9. Genie HC1024

    2  Pages

  10. Genie C1280

    2  Pages

  11. Falcon2 8M

    2  Pages

  12. Falcon2 4M

    2  Pages

  13. Falcon2 12M

    2  Pages

  14. Falcon 4M60

    2  Pages

  15. BOA IDR

    2  Pages

  16. Genie M1024

    2  Pages

  17. Genie C1024

    2  Pages

  18. Eclipse

    2  Pages

  19. BOA

    2  Pages

  20. Spyder3 GigE

    2  Pages

  21. FTF3021M

    2  Pages

  22. IT-P1

    2  Pages

  23. PC2-Camlink

    4  Pages

  24. X64-AN Quad

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.