Model 465L + O2 Industrial Hygiene Ozone Analyzer with Oxygen Sensor The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NIST traceable and the included pressure and temperature compensation ensure high accuracy under all conditions. An integral micro fuel cell sensor provides accurate, continous monitoring of O2 and allows measuring of 8 O3 and O2 monitoring in a single wall mounted unit 8 UV absorption ozone measurement with a 3 ppb LDL 8 Maintenance-free, expendable micro fuel O2 cell both gases in a single instrument. 8 Programmable concentration alarms The Model 465L + O2 has been designed to deliver excellent 8 Programmable High and High-High performance, high reliability and simple operation. Operating alarm contacts parameters can be easily set up in the field using the operator- 8 Self-check warning alarms friendly menu driven software. 8 Temperature and pressure compensation (standard) Built-in diagnostics provide warning signals in case operating parameters are out of range. Test values can be viewed while the Model 465L + O2 is operating. These displays, warnings, and 8 Menu driven software self-diagnostics, along with the modular design, allow maximum 8 Fast response times uptime. In addition, any function that can be set or monitored from the front panel can be remotely set or viewed through the bi-directional RS-232 port. 8 Minimal zero drift 8 Optional Ethernet 8 One-year warranty Free Customer Support by telephone and email for the life of the instrument
Open the catalog to page 1Model 465L + O2 Industrial Hygiene Ozone Analyzer with Oxygen Sensor How to Order Model 465L + O2 includes: General Temperature Range: Sample Flow Rate: Relay Mode: 5 – 45˚C 800 cc/min Latching/Non-latching (selectable) Ozone Destructor UV Absorption 0-1 ppm to 0-500 ppm +/- 1% of full scale +/- 0.5% of full scale < 30 seconds to 95% 3 ppb Status output Measurement Principle: Ranges: Accuracy: Precision: Response Time: Lower Detectable Limit: Analog output Internal pump Select DC output voltage 5V Select ozone range Measurement Principle: Ranges: Accuracy: Precision: Response Time: Lower Detectable...
Open the catalog to page 22 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
2 Pages
2 Pages
2 Pages
4 Pages
6 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages