Chemiluminescence NH3 Analyzer: Model 201E

Chemiluminescence NH3 Analyzer: Model 201E

Chemiluminescence NH3 Analyzer: Model 201E

Product catalog summary
Overview: The Model 201E Chemiluminescence NH3 Analyzer is designed for measuring ambient ammonia in air quality monitoring. It operates using the chemiluminescence principle and features a Teledyne API-designed external ammonia converter and sampling system.
Specifications:
  • Measurement Ranges: Selectable from 0-50 ppb to 0-2,000 ppb in 1 ppb increments.
  • Units: ppb, ppm, µg/m3, mg/m3.
  • Zero Noise: Less than 0.5 ppb RMS.
  • Span Noise: 1% of reading.
  • Lower Detectable Limit: 1 ppb.
  • Zero Drift: 0.5 ppb/24 hours.
  • Span Drift: 1% of full scale/24 hours.
  • Lag Time: 40 seconds.
  • Rise and Fall Time: Less than 300 seconds to 90%.
  • Linearity: 1% of full scale.
  • Sample Flow Rate: 1000 cm3/min ±10%.
  • Operating Temperature Range: 15 - 40˚C.
  • Dimensions: Analyzer & Converter each 7” x 17” x 23.5”.
  • Weight: Analyzer 43 lbs, Converter 24 lbs, External Pump 16 lbs.
  • Power: Various AC voltages and frequencies supported.
  • Outputs: Analog (10V, 5V, 1V, 0.1V), Serial (RS-232, RS-485, Ethernet), Current (0-20 mA or 4-20 mA).
Features:
  • Microprocessor controlled with multi-tasking software.
  • Continuous self-checking with warning alarms.
  • External converter designed to optimize response times.
  • Continuous automatic zero correction and adaptive signal filtering.
  • Temperature and pressure compensation.
  • Internal data logging with averages from 1 minute to 24 hours.
Operation: The analyzer uses a two-step conversion process to measure NH3. Sample gas is first passed through a converter to produce total oxides of nitrogen (TNX), then through a molybdenum converter to produce a Tn reading. The difference (TNX – TN) gives the NH3 concentration.
Ordering Information: Specify input AC voltage and frequency, output DC voltage, and optional equipment such as rack mount brackets, isolated outputs, and calibration options.
Additional Information: For more details, contact Teledyne API or visit their website.
See more

Catalog excerpts

Chemiluminescence NH3 Analyzer: Model 201E-1

Chemiluminescence NH3 Analyzer for Ambient Air Quality Monitoring The Model 201E analyzer measures ambient ammonia in selectable ranges from 0-50 ppb to 0-2,000 ppb using the chemiluminescence principle and a Teledyne API designed external ammonia converter and sampling system. Ranges are user selectable in 1 ppb increments and auto ranging is available. Ammonia is difficult to measure accurately because of a tendency to be absorbed into other materials. The “stickiness” of the gas results in slow response times and inaccurate concentration values. The Model 201E has 0-50 ppb to 0-2,000 ppb, user selectable been designed to overcome the problems of ammonia Microprocessor controlled gas analysis through increased flow, minimum surface Multi-tasking software allows viewing of test variables during operation area and selected construction materials. Continuous self checking with warning alarms converter, which converts NH3 and other compounds to In operation, sample gas is passed through the 501NH NO, producing the total oxides of nitrogen (TNX). In the External converter next cycle the sample is routed through a molybdenum Designed to optimize response times converter which converts nitrogen oxides (less NH3) to – Minimal surface area in contact with sample NO, producing the Tn reading. The difference between – low absorption wetted parts – heated zero/span manifold these readings (TNX – TN = NH3) provides a reading proportional to the NH3 concentration. The analyzer software represents these values in the readout, and Continuous Automatic Zero correction Adaptive signal filtering optimizes response time independent outputs are available for each of these values. The Model 201E combines the performance advantages Temperature & pressure compensation Internal data logging with 1 min to 24 hour averages of Teledyne API’s Model 200E NO/NOX analyzer with a converter sampling system designed specifically for this application to produce the most accurate and dependable NH3 measurement system available today. FREE Customer Support by telephone and email for the life of the instrument

 Open the catalog to page 1
Chemiluminescence NH3 Analyzer: Model 201E-2

Chemiluminescence NH3 Analyzer for Ambient Air Quality Monitoring Specifications Ranges (measureable units): Analyzer: 43 lbs (20 kg) Converter: 24 lbs (11 kg) External Pump: 16 lbs (7 kg) Analog Outputs: Recorder Offset: Serial Outputs: Serial Port 1: RS-232, DB-9M Serial Port 2: standard RS-232 or optional RS-485, DB-9F, or Ethernet Status (Digital) 12 outputs (opto-isolated), 4 alarm outputs (optional) Current Output: 0-20 mA or 4-20 mA isolated outputs (optional) independent NH3, NO, NO2, NOx ranges supported Units: Zero Noise: Span Noise: Lower Detectable Limit (LDL): 1 ppb Zero Drift: Span...

 Open the catalog to page 2

All Teledyne API catalogs and technical brochures

  1. T200

    2  Pages

  2. T108

    2  Pages

  3. T102

    2  Pages

  4. T101

    2  Pages

  5. T100H

    2  Pages

  6. CAT-O3 Series

    2  Pages

  7. ​SCI-552

    2  Pages

  8. ​Model ODS

    2  Pages

  9. Mini ODS

    2  Pages

  10. Model 651

    2  Pages

  11. T640

    4  Pages

  12. 452

    2  Pages

  13. 465H

    2  Pages

  14. 465M

    2  Pages

  15. Model 702

    2  Pages

  16. Model T204

    2  Pages

  17. Model T700H

    2  Pages

  18. Model 751H

    2  Pages

  19. Model 751

    2  Pages

  20. T701H

    2  Pages

  21. T701

    2  Pages

  22. T750

    2  Pages

  23. T500U

    2  Pages

  24. T750U

    2  Pages

Archived catalogs

  1. T Series

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.