Catalog excerpts
Chemiluminescence NH3 Analyzer for Ambient Air Quality Monitoring The Model 201E analyzer measures ambient ammonia in selectable ranges from 0-50 ppb to 0-2,000 ppb using the chemiluminescence principle and a Teledyne API designed external ammonia converter and sampling system. Ranges are user selectable in 1 ppb increments and auto ranging is available. Ammonia is difficult to measure accurately because of a tendency to be absorbed into other materials. The “stickiness” of the gas results in slow response times and inaccurate concentration values. The Model 201E has 0-50 ppb to 0-2,000 ppb, user selectable been designed to overcome the problems of ammonia Microprocessor controlled gas analysis through increased flow, minimum surface Multi-tasking software allows viewing of test variables during operation area and selected construction materials. Continuous self checking with warning alarms converter, which converts NH3 and other compounds to In operation, sample gas is passed through the 501NH NO, producing the total oxides of nitrogen (TNX). In the External converter next cycle the sample is routed through a molybdenum Designed to optimize response times converter which converts nitrogen oxides (less NH3) to – Minimal surface area in contact with sample NO, producing the Tn reading. The difference between – low absorption wetted parts – heated zero/span manifold these readings (TNX – TN = NH3) provides a reading proportional to the NH3 concentration. The analyzer software represents these values in the readout, and Continuous Automatic Zero correction Adaptive signal filtering optimizes response time independent outputs are available for each of these values. The Model 201E combines the performance advantages Temperature & pressure compensation Internal data logging with 1 min to 24 hour averages of Teledyne API’s Model 200E NO/NOX analyzer with a converter sampling system designed specifically for this application to produce the most accurate and dependable NH3 measurement system available today. FREE Customer Support by telephone and email for the life of the instrument
Open the catalog to page 1Chemiluminescence NH3 Analyzer for Ambient Air Quality Monitoring Specifications Ranges (measureable units): Analyzer: 43 lbs (20 kg) Converter: 24 lbs (11 kg) External Pump: 16 lbs (7 kg) Analog Outputs: Recorder Offset: Serial Outputs: Serial Port 1: RS-232, DB-9M Serial Port 2: standard RS-232 or optional RS-485, DB-9F, or Ethernet Status (Digital) 12 outputs (opto-isolated), 4 alarm outputs (optional) Current Output: 0-20 mA or 4-20 mA isolated outputs (optional) independent NH3, NO, NO2, NOx ranges supported Units: Zero Noise: Span Noise: Lower Detectable Limit (LDL): 1 ppb Zero Drift:...
Open the catalog to page 2All Teledyne API catalogs and technical brochures
-
T200
2 Pages
-
T108
2 Pages
-
T102
2 Pages
-
T101
2 Pages
-
T100H
2 Pages
-
CAT-O3 Series
2 Pages
-
SCI-552
2 Pages
-
OG-5000 Series
2 Pages
-
Model ODS
2 Pages
-
Mini ODS
2 Pages
-
T SERIES_BROCHURE_2018
6 Pages
-
Model dFFOZ-TR
2 Pages
-
The Model T200P
2 Pages
-
Model 651
2 Pages
-
T640
4 Pages
-
T Series Instruments
6 Pages
-
The Model T703
2 Pages
-
NumaView software
4 Pages
-
The Model T640
4 Pages
-
452
2 Pages
-
465H
2 Pages
-
465M
2 Pages
-
Model 702
2 Pages
-
Model T204
2 Pages
-
Model T700H
2 Pages
-
Model 751H
2 Pages
-
Model 751
2 Pages
-
T701H
2 Pages
-
T701
2 Pages
-
T750
2 Pages
-
CAPS NO 2 Analyzer
4 Pages
-
T500U
2 Pages
-
T750U
2 Pages
-
Model 602 BetaPLUS
4 Pages
-
Calibrators T700U
2 Pages
Archived catalogs
-
Calibrators T700
2 Pages
-
T Series
6 Pages
-
Total Sulfur Analyzer
2 Pages
-
UV Fluorescence SO2 Analyzer
2 Pages