ADVANCED POLLUTION INSTRUMENTATION A Teledyne Technologies Company Model T700U Dynamic Dilution Calibrator The Model T700U is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of ultra-sensitive measurements. The ability to calibrate and verify linearity for N02 at levels below 5 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of N02 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software. New - Ultra-stable ozone output to ►► Ultra-low gas phase titration (GPT) ►► Built-in photometer, ozone generator, ►► Large, vivid, and durable color graphics display with touch screen ►► Front panel USB connections for peripheral devices and firmware ►► 12 independent timers for sequences ►► Nested sequences (up to 5 levels) ►► Software linearization of mass flow ►► 4 calibration ports (configurable for single or multi-blend gases) ►► 3rcl MFC for wide dynamic range ►► Glass gas phase titration chamber ►► Inlets for external ozone reference Free Customer Support by telephone and email for the life of the instrument
Open the catalog to page 1Model T700U Dynamic Dili Dilution System Flow Measurement Accuracy: Linearity of Flow Measurements: Flow Range of Dilution Air: Flow Range of Cylinder Gases: Input Pressure: Calibration Gas Input Ports: Diluent Gas Input Ports: Minimum Output:_ Minimum Concentration: Ozone Generator Module Maximum Output:_ Minimum Output: Minimum Ozone Concentration: Response Time: Optical Feedback: Rise/Fall Time: <20 seconds (photometer response) Response Time: Zero Drift: 180 seconds to 95% (system response) Electrical Specifications Power Requirements: Analog Output Ranges (Test Channel): 10V, 5V, 1V,...
Open the catalog to page 2All Teledyne API catalogs and technical brochures
-
T200
2 Pages
-
T108
2 Pages
-
T102
2 Pages
-
T101
2 Pages
-
T100H
2 Pages
-
CAT-O3 Series
2 Pages
-
SCI-552
2 Pages
-
OG-5000 Series
2 Pages
-
Model ODS
2 Pages
-
Mini ODS
2 Pages
-
T SERIES_BROCHURE_2018
6 Pages
-
Model dFFOZ-TR
2 Pages
-
The Model T200P
2 Pages
-
Model 651
2 Pages
-
T640
4 Pages
-
T Series Instruments
6 Pages
-
The Model T703
2 Pages
-
NumaView software
4 Pages
-
The Model T640
4 Pages
-
452
2 Pages
-
465H
2 Pages
-
465M
2 Pages
-
Model 702
2 Pages
-
Model T204
2 Pages
-
Model T700H
2 Pages
-
Model 751H
2 Pages
-
Model 751
2 Pages
-
T701H
2 Pages
-
T701
2 Pages
-
T750
2 Pages
-
CAPS NO 2 Analyzer
4 Pages
-
T500U
2 Pages
-
T750U
2 Pages
-
Model 602 BetaPLUS
4 Pages
Archived catalogs
-
Calibrators T700
2 Pages
-
T Series
6 Pages
-
Total Sulfur Analyzer
2 Pages
-
UV Fluorescence SO2 Analyzer
2 Pages