Group: Teledyne Technologies Incorporated
Catalog excerpts
Fluorescent High Range SO2 Analyzer The Model 100EH SO2 Analyzer is a rugged yet sensitive UV Fluorescence analyzer with the high measurement ranges and interferent rejection needed for extractive source monitoring. Modifications to the ambient Model 100E give the analyzer its ability to measure very high concentrations and greatly reduces the effects of interferents in the sample stream. Standard two year warranty Specifically, there is minimal quenching by O2 or CO2 Ranges, 0-10 to 0-5,000 ppm, user selectable and less than a 0.1% response to water. In addition, special optical filtering reduces the effects of NO Dual ranges and auto ranging interference. Multi-tasking software allows field range Microprocessor controlled for versatility changes as well as auto ranging and dual range Excellent zero/span stability Minimum quenching effect from CO2 or O2 Excellent interferent rejection (NO and water) Displays test variables during operation The intuitive menu-driven program makes the operator interface easy and provides complete accessibility. The Model 100EH can be controlled through the front panel or remotely via RS-232 or Ethernet. Built-in diagnostics, electrical and optical tests and warning alarms simplify Temperature and pressure compensation troubleshooting. Fast response (<30 seconds to 95%) Continuous self checking with warning alarms For a broad range of CEM and stack testing applications, the Model 100EH provides a simple but precise solution to SO2 monitoring. Dual, bi-directional RS-232 ports for remote operation (optional RE-485 or Ethernet) FREE Customer Support by telephone and email for the life of the instrument
Open the catalog to page 1Fluorescent High Range Zero Noise: Zero Drift: Span Noise: Span Drift: Lower Detectable Limit (LDL): Response Time: Sample Flow Rate: Linearity error: Range increment: Operating Temperature Range: 0-10 to 0-5,000 ppm, full scale, user selectable. Dual ranges and auto ranging supported Dimensions (HxWxD): Analog Outputs: Current Output: Recorder Offset: Serial Outputs: Status (Digital) Optional 4-20 mA isolated outputs (select up Serial Port 2: standard RS-232 or optional 8 outputs, 6 inputs (opto-isolated), 4 alarm outputs (optional) NOTE: The values expressed above are in accordance with...
Open the catalog to page 2All Teledyne API catalogs and technical brochures
-
T200
2 Pages
-
T108
2 Pages
-
T102
2 Pages
-
T101
2 Pages
-
T100H
2 Pages
-
CAT-O3 Series
2 Pages
-
SCI-552
2 Pages
-
OG-5000 Series
2 Pages
-
Model ODS
2 Pages
-
Mini ODS
2 Pages
-
T SERIES_BROCHURE_2018
6 Pages
-
Model dFFOZ-TR
2 Pages
-
The Model T200P
2 Pages
-
Model 651
2 Pages
-
T640
4 Pages
-
T Series Instruments
6 Pages
-
The Model T703
2 Pages
-
NumaView software
4 Pages
-
The Model T640
4 Pages
-
452
2 Pages
-
465H
2 Pages
-
465M
2 Pages
-
Model 702
2 Pages
-
Model T204
2 Pages
-
Model T700H
2 Pages
-
Model 751H
2 Pages
-
Model 751
2 Pages
-
T701H
2 Pages
-
T701
2 Pages
-
T750
2 Pages
-
CAPS NO 2 Analyzer
4 Pages
-
T500U
2 Pages
-
T750U
2 Pages
-
Model 602 BetaPLUS
4 Pages
-
Calibrators T700U
2 Pages
Archived catalogs
-
Calibrators T700
2 Pages
-
T Series
6 Pages
-
Total Sulfur Analyzer
2 Pages
-
UV Fluorescence SO2 Analyzer
2 Pages